A 6.6-kV transformerless shunt hybrid active filter for installation on a power distribution system

被引:0
|
作者
Inzunza, R [1 ]
Akagi, H [1 ]
机构
[1] Tokyo Inst Technol, Tokyo 152, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a fully-digital-controlled shunt hybrid filter for damping of harmonic propagation in power distribution systems. The harmonic propagation is caused by resonance between line inductances and power capacitors installed for power factor correction. A possible solution to damping out harmonic propagation is based on installation of a shunt pure active filter at the end of a feeder. This paper proposes a shunt hybrid active filter characterized by series connection of a 7th-tuned LC filter per phase and a small-rated three-phase active filter. Like the pure filter, the hybrid filter is connected to the end bus of a feeder. The capacitor of the LC filter imposes a high impedance to the fundamental frequency, so that the fundamental voltage appears across the capacitor. This unique feature allows us to directly connect the hybrid filter to the 6.6-kV power line without step-down transformers. Furthermore, the capacitor used in this hybrid filter is lighter, cheaper and smaller than the transformer used in the pure filter. Theoretical analysis, along with experimental results obtained from a 200-V, 20-kW laboratory system, verifies the viability and effectiveness of the proposed hybrid filter.
引用
收藏
页码:4630 / 4636
页数:7
相关论文
共 50 条
  • [31] A Noble Transformer Coupled Shunt Active Hybrid Power Filter
    Ray, Anirban Sinha
    Bhattacharya, Avik
    [J]. 2015 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2015, : 2571 - 2579
  • [32] Compensation characteristics of a novel shunt hybrid active power filter
    Wang, Y
    Wang, ZA
    Yang, J
    Liu, JJ
    Guo, ZB
    Wang, WA
    Liu, T
    [J]. 2005 IEEE 36th Power Electronic Specialists Conference (PESC), Vols 1-3, 2005, : 2598 - 2602
  • [33] New Control System of the Shunt Active Power Filter
    Strzelecki, R.
    Wojciechowski, M.
    [J]. 2008 INTERNATIONAL SCHOOL ON NONSINUSOIDAL CURRENTS AND COMPENSATION, 2008, : 227 - 231
  • [34] New Control System of the Shunt Active Power Filter
    Wojciechowski, Daniel
    Strzelecki, Ryszard
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (11): : 303 - 307
  • [35] Predictive Control System of the Shunt Active Power Filter
    Wojciechowski, M.
    Strzelecki, R.
    Benysek, G.
    [J]. BEC 2008: 2008 INTERNATIONAL BIENNIAL BALTIC ELECTRONICS CONFERENCE, PROCEEDINGS, 2008, : 309 - 312
  • [36] Performance of the 6.6-kV 200-kVA Transformerless SDBC-Based STATCOM Using 3.3-kV SiC-MOSFET Modules for Reactive-Power Compensation
    Tajyuta, Toshihisa
    Maharjan, Laxman
    Maruyama, Koji
    Toba, Akio
    Suzuki, Akio
    Shinohara, Hiroshi
    Kaneko, Tomomi
    [J]. 2020 THIRTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2020), 2020, : 2297 - 2302
  • [37] Comparisons between a hybrid shunt active filter and a pure shunt active filter
    Tamai, Y
    Srianthumrong, S
    Akagi, H
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 2005, 153 (02) : 61 - 70
  • [38] A 6.6-kV Transformerless Cascade PWM STATCOM. Experimental Verification by a Three-Phase 200-V, 10-kVA Laboratory System
    Yoshi, Tsurugi
    Inoue, Shigenori
    Akagi, Hirofumi
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 2010, 170 (01) : 55 - 64
  • [39] Considerations of a shunt active filter based on voltage detection for installation on a long distribution feeder
    Wada, K
    Fujita, H
    Akagi, H
    [J]. CONFERENCE RECORD OF THE 2001 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2001, : 157 - 163
  • [40] Considerations of a shunt active filter based on voltage detection for installation on a long distribution feeder
    Wada, K
    Fujita, H
    Akagi, H
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2002, 38 (04) : 1123 - 1130