Experimental and numerical investigation of mechanically ventilated rooms

被引:2
|
作者
Teodosiu, Raluca [1 ]
David, Damien [2 ,4 ]
Teodosiu, Catalin [1 ]
Rusaouen, Gilles [2 ,4 ]
Ilie, Viorel [1 ]
Chi-Kien Nguyen [3 ,4 ]
机构
[1] Tech Univ Civil Engn, 122-124 Lacul Tei Bvd, Bucharest 020396, Romania
[2] Univ Lyon, F-69361 Lyon 07, France
[3] INSA Lyon, 20 Ave Albert Einstein, F-69100 Villeurbanne, France
[4] CETHIL UMR5008, F-69621 Villeurbanne, France
关键词
full-scale test room; CFD modeling; mechanically ventilated rooms; experimental validation; INDOOR AIR-QUALITY; CFD SIMULATION; DISPLACEMENT VENTILATION; THERMAL COMFORT; ENVIRONMENT; FLOW;
D O I
10.1016/j.egypro.2017.03.1094
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The aim of this study is to make available new data concerning the validation of CFD (Computational Fluid Dynamics) results through experimental measurements campaigns on full scale mechanically ventilated test rooms. The experimental set-up is based on a new configuration of the test cell "Minibat" (CETHIL - INSA Lyon, France), equipped with a realistic mixing ventilation system. In this paper, experimental - numerical comparisons are presented in terms of mean air velocity for an isothermal situation. The investigations have been focused in the region near the supply air diffuser as the overall air flow in ventilated enclosures is mainly due to the inlet air jet. The results show a decent agreement between measurements and numerical values in terms of velocity profile at the inlet. In addition, the overall flow development in the air jet is well represented numerically. However, there are some discrepancies concerning the point of maximum velocity in the air jet which must be addressed by further investigations, both experimentally and numerically. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:252 / 260
页数:9
相关论文
共 50 条
  • [41] Numerical and experimental validation procedures for the simulation of refrigerated rooms
    Pitarma, RA
    Ramos, JE
    Carvalho, MG
    Computational Methods and Experimental Measurements XII, 2005, 41 : 715 - 726
  • [42] Experimental and numerical study of low frequency oscillatory behaviour of a large-scale hydrocarbon pool fire in a mechanically ventilated compartment
    Pretrel, Hugues
    Suard, Sylvain
    Audouin, Laurent
    FIRE SAFETY JOURNAL, 2016, 83 : 38 - 53
  • [43] Experimental and numerical investigation of hydrodynamics and mixing in a dual-impeller mechanically-stirred digester
    Trad, Zaineb
    Fontaine, Jean-Pierre
    Larroche, Christian
    Vial, Christophe
    Chemical Engineering Journal, 2017, 329 : 142 - 155
  • [44] Experimental and numerical investigation of hydrodynamics and mixing in a dual-impeller mechanically-stirred digester
    Trad, Zaineb
    Fontaine, Jean-Pierre
    Larroche, Christian
    Vial, Christophe
    CHEMICAL ENGINEERING JOURNAL, 2017, 329 : 142 - 155
  • [45] Air ion behavior in ventilated rooms
    Fletcher, L. A.
    Noakes, C. J.
    Sleigh, P. A.
    Beggs, C. B.
    Shepherd, S. J.
    INDOOR AND BUILT ENVIRONMENT, 2008, 17 (02) : 173 - 182
  • [46] Personal exposure in displacement ventilated rooms
    Brohus, H
    Nielsen, PV
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (03): : 157 - 167
  • [47] NUMERICAL INVESTIGATION ON THERMAL BEHAVIORS OF AN INCLINED VENTILATED ROOF
    Manca, Oronzio
    Mangiacapra, Antonio
    Marino, Salvatore
    Nardini, Sergio
    PROCEEDINGS OF THE ASME 12TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS - 2014, VOL 2, 2014,
  • [48] AN EXPERIMENTAL-STUDY ON HUMAN SENSATION TO AIR-FLOW IN NATURALLY VENTILATED ROOMS
    ISHII, A
    SAKAKIBARA, N
    KATAYAMA, T
    TSUTSUMI, J
    NISHIDA, M
    ENVIRONMENT INTERNATIONAL, 1990, 16 (01) : 61 - 70
  • [49] Monitoring the mechanically ventilated patient
    Bekos, Vasileios
    Marini, John J.
    CRITICAL CARE CLINICS, 2007, 23 (03) : 575 - +
  • [50] Ribavirin in mechanically ventilated infants
    Hubert, P
    ARCHIVES DE PEDIATRIE, 1996, 3 (02): : 186 - 186