Flow cytometry and molecular methods reach similar sensitivity in detection of minimal residual disease in ALL.

被引:0
|
作者
Pisa, P
Malec, M
Bjorklund, E
Soderha, S
PorwitMacDonald, A
机构
[1] KAROLINSKA HOSP,DEPT HEMATOL & INFECT DIS,S-10401 STOCKHOLM,SWEDEN
[2] KAROLINSKA HOSP,DEPT PATHOL,S-10401 STOCKHOLM,SWEDEN
[3] KAROLINSKA HOSP,DEPT PEDIAT ONCOL,S-10401 STOCKHOLM,SWEDEN
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:3725 / 3725
页数:1
相关论文
共 50 条
  • [21] The role of multiparametric flow cytometry in the detection of minimal residual disease in acute leukaemia
    Lee, Denise
    Grigoriadis, George
    Westerman, David
    PATHOLOGY, 2015, 47 (07) : 609 - 621
  • [22] Minimal/Measurable Residual Disease Detection in Acute Leukemias by Multiparameter Flow Cytometry
    Franklin Fuda
    Weina Chen
    Current Hematologic Malignancy Reports, 2018, 13 : 455 - 466
  • [24] FLOW-CYTOMETRY IN MINIMAL RESIDUAL DISEASE ASSESSMENT
    LAMY, B
    HERVE, P
    TISSOT, C
    PETERS, A
    PATHOLOGIE BIOLOGIE, 1988, 36 (01): : 29 - 36
  • [25] Two Colour Flow Cytometry Intensified by The Lysys II Program (Becton Dickinson) in The Detection of Minimal Residual Disease of All
    E P Klykova
    N A Torubarova
    E Semikina
    Pediatric Research, 1999, 45 : 774 - 774
  • [26] Two colour flow cytometry intensified by LYSYS II program (Becton Dickinson) in the detection of minimal residual disease of all
    Klykova, EP
    Torubarova, NA
    Semikina, E
    PEDIATRIC RESEARCH, 1999, 45 (05) : 774 - 774
  • [27] Minimal residual disease detection by flow cytometry: can it serve as a predictor of future relapse?
    Felgar, RE
    LEUKEMIA RESEARCH, 2001, 25 (05) : 409 - 411
  • [28] Impact of pretransplant minimal residual disease detection by flow cytometry in acute myeloid leukemia
    Perez, E.
    Lopez-Godino, O.
    Cabrero, M.
    Labrador, J.
    Alonso, S.
    Perez, J. J.
    Lopez-Corral, L.
    Vazquez, L.
    Gonzalez, M.
    Hernadez, J. M.
    Puig, N.
    Diez-Campelo, M.
    Martin, A.
    Mateos, M. V.
    Paiva, B.
    del Canizo, M. C.
    San Miguel, J.
    Caballero, M. D.
    Vidriales, M. B.
    BONE MARROW TRANSPLANTATION, 2015, 50 : S238 - S239
  • [29] The Role of Multiparameter Flow Cytometry for Detection of Minimal Residual Disease in Acute Myeloid Leukemia
    Al-Mawali, Adhra
    Gillis, David
    Lewis, Ian
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2009, 131 (01) : 16 - 26
  • [30] Immunophenotypic aberrations applicable for the minimal residual disease monitoring in BII-ALL by flow cytometry
    Popov, A.
    Verzhbitskaya, T.
    Saveliev, L.
    Fechina, L.
    ANNALS OF HEMATOLOGY, 2008, 87 : S7 - S7