T1 and T2 Values of Human Neonatal Blood at 3 Tesla: Dependence on Hematocrit, Oxygenation, and Temperature

被引:57
|
作者
Liu, Peiying [1 ,2 ]
Chalak, Lina F. [3 ]
Krishnamurthy, Lisa C. [2 ]
Mir, Imran [3 ]
Peng, Shin-lei [1 ,2 ]
Huang, Hao [2 ,4 ,5 ]
Lu, Hanzhang [1 ,2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21287 USA
[2] Univ Texas SW Med Ctr Dallas, Adv Imaging Res Ctr, Dallas, TX 75390 USA
[3] Univ Texas SW Med Ctr Dallas, Dept Pediat, Dallas, TX 75390 USA
[4] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
[5] Univ Penn, Dept Radiol, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
umbilical cord blood; longitudinal relaxation time; transverse relaxation time; blood oxygenation; hematocrit; neonate; HYPOXIC-ISCHEMIC ENCEPHALOPATHY; THERAPEUTIC HYPOTHERMIA; QUANTITATIVE ASSESSMENT; EXTRACTION RATIOS; BRAIN PERFUSION; MRI; T-1; ARTERIAL; NEWBORNS; METABOLISM;
D O I
10.1002/mrm.25775
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Knowledge of blood T1 and T2 is of major importance in many applications of MRI in neonates. However, to date, there has not been a systematic study to examine neonatal blood T1/T2 relaxometry. This present study aims to investigate this topic. Methods: Using freshly collected blood samples from human umbilical cord, we performed in vitro experiments under controlled physiological conditions to measure blood T1 and T2 at 3 Tesla (T) and their dependence on several factors, including hematocrit (Hct), oxygenation (Y) and temperature. Results: The arterial T1 in neonates was 18256184 ms (Hct = 0.42 +/- 0.08), longer than that of adult blood. Neonatal blood T1 was strongly dependent on Hct (P < 0.001) and Y (P = 0.005), and the dependence of T1 on Y was more prominent at higher Hct. The arterial T2 of neonatal blood was 191 ms at an Hct of 0.42, which was also longer than adult blood. Neonatal blood T2 was positively associated with blood oxygenation and negatively associated with hematocrit level, and can be characterized by an exchange model. Neonatal blood T1 was also positively associated with temperature (P < 0.001). Conclusion: The values provided in this report may provide important reference and calibration information for sequence optimization and quantification of in vivo neonatal MRI studies. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1730 / 1735
页数:6
相关论文
共 50 条
  • [21] 7 Tesla quantitative hip MRI: T1, T2 and T2* mapping of hip cartilage in healthy volunteers
    Andrea Lazik
    Jens M. Theysohn
    Christina Geis
    Sören Johst
    Mark E. Ladd
    Harald H. Quick
    Oliver Kraff
    European Radiology, 2016, 26 : 1245 - 1253
  • [22] 7 Tesla quantitative hip MRI: T1, T2 and T2☆ mapping of hip cartilage in healthy volunteers
    Lazik, Andrea
    Theysohn, Jens M.
    Geis, Christina
    Johst, Soeren
    Ladd, Mark E.
    Quick, Harald H.
    Kraff, Oliver
    EUROPEAN RADIOLOGY, 2016, 26 (05) : 1245 - 1253
  • [23] BETWEEN T1 AND T2
    WILANSKY, A
    AMERICAN MATHEMATICAL MONTHLY, 1967, 74 (03): : 261 - &
  • [24] Dependence of Blood T2 on Oxygenation at 7 T: In Vitro Calibration and In Vivo Application
    Krishnamurthy, Lisa C.
    Liu, Peiying
    Xu, Feng
    Uh, Jinsoo
    Dimitrov, Ivan
    Lu, Hanzhang
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 2035 - 2042
  • [25] 3 Tesla T1 / T2 ratio imaging improves cortical lesion contrast in multiple sclerosis
    Manning, A. R.
    Beck, E. S.
    Schindler, M. K.
    Nair, G.
    Parvathaneni, P.
    Reich, D. S.
    Shinohara, R. T.
    Solomon, A. J.
    MULTIPLE SCLEROSIS JOURNAL, 2022, 28 (3_SUPPL) : 252 - 253
  • [26] Age and sex corrected normal reference values of T1, T2 T2*and ECV in healthy subjects at 3T CMR
    Roy, Clotilde
    Slimani, Alisson
    de Meester, Christophe
    Amzulescu, Mihaela
    Pasquet, Agnes
    Vancraeynest, David
    Vanoverschelde, Jean-Louis
    Pouleur, Anne-Catherine
    Gerber, Bernhard L.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [27] (T2,T1/T2)Two-DimensionalNMRMethodforGasLayersTyping
    XIE RanhongXIAO LizhiState Key Laboratory of Petroleum Resource and ProspectingChina University of PetroleumBeijing ChinaKey Laboratory of Earth Prospecting and Information TechnologyChina University of PetroleumBeijing China
    测井技术, 2010, 34 (02) : 115 - 119
  • [28] Native T1 and T2 reference values for maltese healthy cohort
    Yamagata, Kentaro
    Yamagata, Lara Marie
    Abela, Mark
    Mifsud, Claude Portanier
    Micallef, Lee Ann
    Reichmuth, Luise
    Borg, Alexander
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (01): : 153 - 159
  • [29] Native T1 and T2 reference values for maltese healthy cohort
    Kentaro Yamagata
    Lara Marie Yamagata
    Mark Abela
    Claude Portanier Mifsud
    Lee Ann Micallef
    Luise Reichmuth
    Alexander Borg
    The International Journal of Cardiovascular Imaging, 2023, 39 : 153 - 159
  • [30] Age and sex corrected normal reference values of T1, T2 T2* and ECV in healthy subjects at 3T CMR
    Clotilde Roy
    Alisson Slimani
    Christophe de Meester
    Mihaela Amzulescu
    Agnès Pasquet
    David Vancraeynest
    Jean-Louis Vanoverschelde
    Anne-Catherine Pouleur
    Bernhard L. Gerber
    Journal of Cardiovascular Magnetic Resonance, 19