3-DOF Force-Sensing Motorized Micro-Forceps for Robot-Assisted Vitreoretinal Surgery

被引:59
|
作者
Gonenc, Berk [1 ]
Chamani, Alireza [1 ]
Handa, James [2 ]
Gehlbach, Peter [2 ]
Taylor, Russell H. [1 ]
Iordachita, Iulian [1 ]
机构
[1] Johns Hopkins Univ, CISST ERC, Baltimore, MD 21218 USA
[2] Johns Hopkins Sch Med, Wilmer Eye Inst, Baltimore, MD 21287 USA
基金
美国国家卫生研究院;
关键词
Fiber Bragg grating; force sensing; micro-forceps; IATROGENIC RETINAL BREAKS; DIABETIC-RETINOPATHY; UNITED-STATES; MICROSURGICAL INSTRUMENT; EPIRETINAL MEMBRANES; STRAIN SENSOR; PREVALENCE; FEEDBACK; TEMPERATURE; TISSUE;
D O I
10.1109/JSEN.2017.2694965
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In vitreoretinal surgery, membrane peeling is a prototypical task where a layer of fibrous tissue is delaminated off the retina with a micro-forceps by applying very fine forces that are mostly imperceptible to the surgeon. Previously, we developed sensitized ophthalmic surgery tools based on fiber Bragg grating strain sensors, which were shown to precisely detect forces at the instrument's tip in two degrees of freedom perpendicular to the tool axis. This paper presents a new design that employs an additional sensor to capture also the tensile force along the tool axis. The grasping functionality is provided via a compact motorized unit. To compute forces, we investigate two distinct fitting methods: a linear regression and a nonlinear fitting based on second-order Bernstein polynomials. We carry out experiments to test the repeatability of sensor outputs, calibrate the sensor, and validate its performance. Results demonstrate sensor wavelength repeatability within 2 pm. Although the linear method provides sufficient accuracy in measuring transverse forces, in the axial direction, it produces a root mean square (rms) error over 3 mN even for a confined magnitude and direction of forces. On the other hand, the nonlinear method provides a more consistent and accurate measurement of both the transverse and axial forces for the entire force range (0-25 mN). Validation, including random samples, shows that our tool with the nonlinear force computation method can predict 3-D forces with an rms error under 0.15 mN in the transverse plane and within 2 mN accuracy in the axial direction.
引用
收藏
页码:3526 / 3541
页数:16
相关论文
共 35 条
  • [31] Combining robot-assisted surgical system and 3D visualization system for teaching minimally invasive vitreoretinal surgery
    Yi-Qi Chen
    Dan Cheng
    Lin Zhu
    Wei-Qian Gao
    Jia-Feng Yu
    Jun Wang
    Xin-Yi Deng
    Ji-Wei Tao
    Jia Qu
    Li-Jun Shen
    International Journal of Ophthalmology, 2022, 15 (02) : 255 - 260
  • [32] A Modular 3-Degrees-of-Freedom Force Sensor for Robot-Assisted Minimally Invasive Surgery Research
    Chua, Zonghe
    Okamura, Allison M. M.
    SENSORS, 2023, 23 (11)
  • [33] An automatic drug injection device with spatial micro-force perception guided by an microscopic image for robot-assisted ophthalmic surgery
    Li, Zhen
    Fu, Pan
    Wei, Bing-Ting
    Wang, Jie
    Li, An-Long
    Li, Ming-Jun
    Bian, Gui-Bin
    FRONTIERS IN ROBOTICS AND AI, 2022, 9
  • [34] Force-driven Robotic Drag Control for Freehand 3D Ultrasound-guided Robot-assisted Percutaneous Surgery
    Sun, Yinshan
    Wu, Dongmei
    Du, Zhijiang
    Sun, Lining
    2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO 2009), VOLS 1-4, 2009, : 1953 - 1956
  • [35] Analysis and Optimization of a 6-DoF 3-<underline>R</underline>R<underline>P</underline>S Parallel Mechanism for Robot-Assisted Long-Bone Fracture Surgery
    Clancy, Michael
    Alruwaili, Fayez
    Saeedi-Hosseiny, Marzieh S.
    McMillan, Sean
    Iordachita, Iulian I.
    Abedin-Nasab, Mohammad H.
    JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME, 2024, 16 (06):