Comparison of computerized methods for detecting the ventilatory thresholds

被引:59
|
作者
Santos, EL [1 ]
Giannella-Neto, A [1 ]
机构
[1] Univ Fed Rio de Janeiro, Biomed Engn Program, Grad Sch Engn, BR-21945970 Rio De Janeiro, Brazil
关键词
anaerobic threshold; automatic detection; progressive exercise; maximum oxygen uptake;
D O I
10.1007/s00421-004-1166-6
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The aim of this study was to compare computerized automatic methods to detect the ventilatory threshold (VT). Thirty apparently healthy and physically active volunteers [22.5 (6.5) years; 1.72 (0.08) m; 71.9 (8.5) kg] were submitted to a progressive and maximal cycle exercise. The gas exchange was monitored breath-by-breath with a fast gas analyser. The VT and respiratory compensation ( RC) were automatically detected based on the respiratory exchange ratio, the ventilatory equivalent for O-2 and the ventilatory equivalent for CO2, pulmonary ventilation, end-tidal PO2 and PCO2, and v-slope. In addition, VT and RC were also determined independently by visual inspection by two experienced investigators, and the results were compared with those of the automatic procedures. The automatic VT averaged 77% of the maximal (V) over dot O-2 and the RC 88%. The agreement between the experienced observers was very close [ mean difference: 44.4 (16.1) ml, r=0.94, not significant]. Data were expressed as the mean value together with the standard deviation in each case. The automatic and visual inspection procedures did not present significant differences, resulting in 29.6 ( 29.6) ml with a reliability of r = 0.86. All methods were significantly correlated for VT and RC ( r = 0.93 on average, P< 0.01). ANOVA did not show differences between either the VT methods (P = 0.131) or the RC methods (P = 0.41). In conclusion, the present study has compared several simultaneous breath-by-breath ergospirometric methods that are used to describe the anaerobic threshold, showing high confidence when compared to visual inspection. No statistical differences were found between the VT and RC techniques for physically active subjects indicating that these methods may be equally effectively employed.
引用
收藏
页码:315 / 324
页数:10
相关论文
共 50 条
  • [21] Ecological threshold and environmental management: A note on statistical methods for detecting thresholds
    Qian, Song S.
    ECOLOGICAL INDICATORS, 2014, 38 : 192 - 197
  • [22] A comparison of survey methods for detecting bobcats
    Harrison, RL
    WILDLIFE SOCIETY BULLETIN, 2006, 34 (02) : 548 - 552
  • [23] Comparison of methods for detecting Blastocystis hominis
    Suresh, K
    Smith, H
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2004, 23 (06) : 509 - 511
  • [25] Comparison of Methods of Detecting Bacterial Biofilm
    Tajima, Yutaka
    Yamaguchi, Tatsuo
    Takagi, Rie
    Nakajima, Tamiko
    Kominato, Yoshihiko
    CLINICAL LABORATORY, 2010, 56 (3-4) : 143 - 147
  • [26] DO LACTATE AND VENTILATORY THRESHOLDS DIFFER
    YAMAMOTO, Y
    HUGHSON, RL
    JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (06) : 2640 - 2641
  • [27] COMPARISON OF METHODS FOR DETECTING LEAKAGES IN PIPELINES
    JEDNER, U
    VOSS, U
    UNBEHAUEN, H
    SCHMITT, K
    TECHNISCHES MESSEN, 1991, 58 (11): : 446 - 451
  • [28] Comparison of methods for detecting Blastocystis hominis
    K. Suresh
    H. Smith
    European Journal of Clinical Microbiology and Infectious Diseases , 2004, 23 : 509 - 511
  • [29] A comparison of methods for detecting hot topics
    Yuen-Hsien Tseng
    Yu-I Lin
    Yi-Yang Lee
    Wen-Chi Hung
    Chun-Hsiang Lee
    Scientometrics, 2009, 81 : 73 - 90
  • [30] A comparison of methods for detecting hot topics
    Tseng, Yuen-Hsien
    Lin, Yu-I
    Lee, Yi-Yang
    Hung, Wen-Chi
    Lee, Chun-Hsiang
    SCIENTOMETRICS, 2009, 81 (01) : 73 - 90