Design of optical bio-sensor using polymeric waveguide

被引:0
|
作者
Borges, BHV [1 ]
de Barros, LEM [1 ]
机构
[1] Univ Sao Paulo, Escola Engn Eletr, Dept Engn Eletr, BR-13560250 Sao Carlos, SP, Brazil
关键词
sensors; optics; coupled-mode theory;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a detailed design of an optical bio-sensor using polymeric waveguides intended for blood glucose concentration measurements. Our proposed device is based on a vertical two-waveguide ARROW structure, simplifying fabrication and avoiding post tuning of sensor parameters. The theoretical analysis based on coupled mode theory and transfer matrix techniques is presented whereby ad device dimensions and parameters are calculated. For a 2cm sensor, output optical power in one guide can swing by approximately 17% depending on glucose concentration. Such results represent a significant improvement in performance when comparing with conventional Mach-Zehnder sensors.
引用
收藏
页码:66 / 69
页数:4
相关论文
共 50 条
  • [21] From the mercury electrode to the Bio-sensor
    Henze, Guenter
    NACHRICHTEN AUS DER CHEMIE, 2008, 56 (10) : 1016 - 1018
  • [22] The Ge Enhance the Sensitivity for Bio-Sensor
    Chang, Kow-Ming
    Kuo, Jiun-Ming
    Chao, Wen-Chan
    Liang, Chia-Jung
    Wu, Heng-Hsin
    Tzeng, Wen-Hsien
    Wu, Tzu-liu
    2008 2ND IEEE INTERNATIONAL NANOELECTRONICS CONFERENCE, VOLS 1-3, 2008, : 811 - 814
  • [23] Various photonic crystal bio-sensor configurations based on optical surface modes
    Kurt, Hamza
    Erim, Muhammed Necip
    Erim, Nur
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 165 (01) : 68 - 75
  • [24] MXene-based wearable bio-sensor
    Meng, You
    Ho, Johnny C.
    JOURNAL OF SEMICONDUCTORS, 2019, 40 (11)
  • [25] Development of a reactor type bio-sensor for trichloroethylene
    Han, TS
    Sasaki, S
    Yano, K
    Ikebukuro, K
    Atsushi, K
    Nagamune, T
    Karube, I
    ANALYTICAL LETTERS, 2003, 36 (03) : 539 - 547
  • [26] A mobile ad hoc bio-sensor network
    Li, YH
    Panwar, SS
    Mao, SW
    Burugupalli, S
    Lee, JH
    ICC 2005: IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS, VOLS 1-5, 2005, : 1241 - 1245
  • [27] The pacemaker electrode as bio-sensor for rate adaptation
    Strobel, JP
    Res, JCJ
    Malinowski, K
    Witte, J
    Ebner, E
    Rodiger, W
    Greco, OT
    Ardito, RV
    Andrade, JCS
    Schaldach, M
    PACEMAKER LEADS 1997, 1997, : 53 - 58
  • [28] Electrochemical bio-sensor for degradation of phenol in the environment
    Maallah, R.
    Moutcine, A.
    Laghlimi, C.
    Smaini, M. A.
    Chtaini, A.
    SENSING AND BIO-SENSING RESEARCH, 2019, 24
  • [29] Advances in Graphene Device & Bio-Sensor Applications
    Matsumoto, K.
    Maehashi, K.
    Ohno, Y.
    Inoue, K.
    PROCEEDINGS OF 2013 TWENTIETH INTERNATIONAL WORKSHOP ON ACTIVE-MATRIX FLATPANEL DISPLAYS AND DEVICES (AM-FPD 13): TFT TECHNOLOGIES AND FPD MATERIALS, 2013, : 63 - 66
  • [30] Design of Sensor Signal Processing Algorithm and Its SoC Architecture for Bio-Sensor Systems and Intelligent Robots
    Jang, Young-Ju
    Kim, Jongsung
    Lee, Seongsoo
    Lee, Seok
    Byun, Youngtae
    AIC '09: PROCEEDINGS OF THE 9TH WSEAS INTERNATIONAL CONFERENCE ON APPLIED INFORMATICS AND COMMUNICATIONS: RECENT ADVANCES IN APPLIED INFORMAT AND COMMUNICATIONS, 2009, : 405 - +