Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels

被引:48
|
作者
Mitragotri, S [1 ]
Coleman, M
Kost, J
Langer, R
机构
[1] Univ Calif Santa Barbara, Dept Chem Engn, Santa Barbara, CA 93106 USA
[2] Univ Colorado, Dept Chem Engn, Boulder, CO 80302 USA
[3] Ben Gurion Univ Negev, Dept Chem Engn, IL-84105 Beer Sheva, Israel
[4] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
[5] Sontra Med, Cambridge, MA 02139 USA
关键词
diabetes; diagnostics; sonophoresis; noninvasive;
D O I
10.1152/jappl.2000.89.3.961
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Transdermal extraction of clinically relevant analytes offers a potentially noninvasive method of diagnostics. However, development of such a method is limited by the low permeability of skin. In this paper, we present a potential method for noninvasive diagnostics based on ultrasonic skin permeabilization and subsequent extraction of interstitial fluid (TSF) across the skin using vacuum. TSF extracted by this method was collected and analyzed for glucose and other analytes. Glucose concentration in the extracted fluid correlates well with blood glucose concentration over a range of 50-250 mg/dl. A mathematical model describing vacuum-induced transport of ISF through ultrasonically permeabilized skin is presented as well. The model accounts for convective, as well as diffusive, transport processes across blood capillaries, epidermis, and the stratum corneum. The overall predictions of the model compare favorably with the experimental observations.
引用
收藏
页码:961 / 966
页数:6
相关论文
共 50 条
  • [31] Intraoperative blood glucose levels in neurosurgical patients - An evaluation of two fluid regimens
    Swamy, MNC
    Murthy, HS
    Rao, GSU
    NEUROLOGY INDIA, 2001, 49 (04) : 371 - 374
  • [32] Glucose as a significant predictor of irisin levels in children
    Nasser, A-D
    Al-Attas, O.
    Alkharfy, K.
    Ur-Rahman, S.
    Amer, O.
    Milan, P.
    McTernan, P.
    Harte, A.
    Alokail, M.
    DIABETOLOGIA, 2013, 56 : S252 - S252
  • [33] Induction of insulin resistance by glucosamine reduces blood flow but not interstitial levels of either glucose or insulin
    Holmäng, A
    Nilsson, C
    Niklasson, M
    Larsson, BM
    Lönroth, P
    DIABETES, 1999, 48 (01) : 106 - 111
  • [34] Discordance between glucose levels measured in the interstitial fluid versus venous plasma after an oral glucose administration: the PRED trial
    Vistisen, D.
    Amadid, H.
    Nielsen, L. B.
    Clemmensen, K. K. B.
    Hulman, A.
    Blond, M. B.
    Jorgensen, M. E.
    Faerch, K.
    DIABETOLOGIA, 2019, 62 : S156 - S157
  • [35] Accuracy of a Blood Glucose Monitoring System at Low Blood Glucose Levels: Analysis of Seven Clinical Studies
    Bellary, Srikanth
    Cameron, Hilary
    Macleod, Kirsty
    Raja, Praveen
    Ellison, John M.
    DIABETES, 2012, 61 : A212 - A212
  • [36] Accuracy of a Blood Glucose Monitoring System at Low Blood Glucose Levels: Analysis of Seven Clinical Studies
    Bellary, Srikanth
    Cameron, Hilary
    Macleod, Kirsty
    Raja, Praveen
    Ellison, John M.
    DIABETES, 2012, 61 : A212 - A212
  • [37] Physiological differences between interstitial and blood glucose
    Kulcu, E
    Lesho, MJ
    Tamada, JA
    Reach, G
    Potts, RO
    DIABETES, 2002, 51 : A11 - A11
  • [38] An analysis of capillary blood glucose levels in hospitalised patients with stroke
    Abduljabbar, M.
    Jones, G.
    Sainsbury, C.
    McAlpine, C.
    McPherson, S.
    Walters, M.
    Dawson, J.
    INTERNATIONAL JOURNAL OF STROKE, 2018, 13 : 15 - 16
  • [39] Optical microsensor for continuous glucose measurements in interstitial fluid
    Olesberg, Jonathon T.
    Cao, Chuanshun
    Yager, Jeffrey R.
    Prineas, John P.
    Coretsopoulos, Chris
    Arnold, Mark A.
    Olafsen, Linda J.
    Santilli, Michael
    OPTICAL DIAGNOSTICS AND SENSING VI, 2006, 6094
  • [40] Glucose monitoring using dermal interstitial fluid.
    Bantle, J
    Thomas, W
    DIABETES, 1997, 46 : 619 - 619