On-chip Structure for Optofluidic Sensing using Stable Fabry-Perot Resonator

被引:1
|
作者
Toraya, Abdelrahman [1 ]
Gaber, Noha [1 ,2 ]
Marty, Frederic [2 ]
Bourouina, Tarik [2 ]
机构
[1] Zewail City Sci & Technol, Ctr Nanotechnol, Giza 12578, Egypt
[2] Univ Paris Est, Lab Elect Syst Commun & Microsyst, ESIEE Paris, ESYCOM EA 2552, F-93162 Noisy Le Grand, France
来源
关键词
Fabry-Perot microcavity; integrated optical resonator; optofluidic sensor; on-chip refractometer; LABEL-FREE DETECTION; SYSTEMS;
D O I
10.1117/12.2582696
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Miniaturizing optical resonators on-chip offers employing them in lab-on-chip sensing devices, which achieves portability, lower price, and only finger prick sample sizes. However, the chip microfabrication limitation may impose some challenges. Taking the Fabry-Perot cavity, the mirrors ideally should have curved shape in 3D to match the light-beam wave front to achieve good light confinement inside the resonator. But as 3D curvature is challenging to fabricate on-chip, straight mirrors are usually used instead with short cavity lengths to avoid high diffraction loss with the beams' multiple trips between the 2 mirrors. The short length limits the sample space between the mirrors, so it can't accommodate large samples such as some types of biological cells. In previous work, the curvature is divided on 2 plans by using cylindrical mirrors for the horizontal plan confinement, and a fiber-rod-lens for the vertical plan confinement. That scheme achieved good light stability; but the curved mirrors produced side peaks as higher order resonance modes, which put limitation on the sensor range. In this work, a novel design is introduced to overcome this limitation by using straight mirrors instead of curved ones, and use an upright cylindrical lens to confine the light in the transverse direction before the cavity. The novel structure is designed by analytical modeling, and verified by numerical simulations. The cavity lengths are typically of tens of micrometers and can reach hundreds, allowing the fluidic channel to hold large test samples. The chip is fabricated in silicon, then fiber-rod-lenses are simply added post-fabrication.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] FABRY-PEROT RESONATOR WITH CIRCULAR APERTURES
    YOSHIDA, Y
    OGURA, H
    IKENOUE, J
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1971, 10 (06) : 754 - &
  • [32] Laser cooling in a Fabry-Perot resonator
    Narducci, FA
    Ye, ZX
    Ling, HY
    JOURNAL OF MODERN OPTICS, 2002, 49 (3-4) : 687 - 704
  • [33] EXCITATION OF SPHERICAL FABRY-PEROT RESONATOR
    YAMADA, R
    KAWANO, M
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1969, 8 (05) : 630 - &
  • [34] PROPERTIES OF AN ANISOTROPIC FABRY-PEROT RESONATOR
    DOYLE, WM
    WHITE, MB
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1965, 55 (10P1) : 1221 - &
  • [35] PLASMA DIAGNOSTICS WITH A FABRY-PEROT RESONATOR
    SESHADRI, SR
    PROCEEDINGS OF THE IEEE, 1969, 57 (06) : 1187 - +
  • [36] Differential Fabry-Perot Resonator Antennas
    Lu, Kai
    Leung, Kwok Wa
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2013, 61 (09) : 4438 - 4446
  • [37] Theory of a gyromagnetic Fabry-Perot resonator
    Lim, SC
    Osman, J
    Tilley, DR
    JOURNAL OF PHYSICS-CONDENSED MATTER, 1997, 9 (39) : 8297 - 8306
  • [38] NONLINEAR DYNAMICS IN A FABRY-PEROT RESONATOR
    LUGIATO, LA
    NARDUCCI, LM
    ZEITSCHRIFT FUR PHYSIK B-CONDENSED MATTER, 1988, 71 (01): : 129 - 138
  • [39] Analysis of a Fabry-Perot open resonator
    Yu, GF
    Dutta, JM
    Jones, CR
    IRMMW-THz2005: The Joint 30th International Conference on Infrared and Millimeter Waves and 13th International Conference on Terahertz Electronics, Vols 1 and 2, 2005, : 363 - 364
  • [40] FABRY-PEROT RESONATOR .I.
    LOTSCH, HKV
    OPTIK, 1968, 28 (01): : 65 - &