摘要
To maintain the life of patients with hemophilia, apoplexy or hemorrhage, appropriate blood coagulation is crucial. To study the microscopic phenomena of blood coagulation and the therapeutic effects of blood medication, optical tweezers were applied to estimate the interaction between red blood cells in the coagulation process. By measuring minimum optical power required to trap the coagulating blood cells, the pN-scale interaction between them can be evaluated. In normal blood sample, the interaction rises in accordance with coagulation time. The addition of heparin attenuates the interaction and postpones the coagulation, whereas the addition of tranexamic acid starts the coagulation early at the beginning and allows the process completed in less time. Blood Coagul Fibrinolysis 21:505-510 (C) 2010 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:505 / 510
页数:6
相关论文
共 50 条
  • [31] Measuring electrical and mechanical properties of red blood cells with double optical tweezers
    Universidade Federal de Pernambuco , Cidade Universitária, Departamento de Biofísica e Radiobiologia, Av. Professor Moraes Rego, 50670-901, Recife-PE, Brazil
    不详
    不详
    不详
    J Biomed Opt, 2008, 1
  • [32] Atorvastatin treatment softens human red blood cells: an optical tweezers study
    Sheikh-Hasani, Vahid
    Babaei, Mehrad
    Azadbakht, Ali
    Pazoki-Toroudi, Hamidreza
    Mashaghi, Alireza
    Moosavi-Movahedi, Ali Akbar
    Reihani, Seyed Nader Seyed
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (03): : 1256 - 1261
  • [33] Probing the Interaction Between Red Blood Cells and Gold Nanoparticles by Optical Tweezer
    Hinge, Sarika
    Banpurkar, Arun
    Kulkarni, Gauri
    BIONANOSCIENCE, 2024, 14 (05) : 5410 - 5419
  • [34] Red blood cell in the field of a beam of optical tweezers
    Ermolinskiy, P. B.
    Lugovtsov, A. E.
    Semenov, A. N.
    Priezzhev, A., V
    QUANTUM ELECTRONICS, 2022, 52 (01) : 22 - 27
  • [35] Nonequilibrium fluctuations of mechanically stretched single red blood cells detected by optical tweezers
    Michal Wojdyla
    Saurabh Raj
    Dmitri Petrov
    European Biophysics Journal, 2013, 42 : 539 - 547
  • [36] Experimental Study on Characteristic Parameters of Red Blood Cells Using the Optical Tweezers System
    Wu, Ying
    Zhu, Chen
    Ruan, Anping
    Liu, Ying
    Han, Caiqin
    2018 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2018,
  • [37] Red blood cells in patients with myocardial infarction using optical tweezers Raman spectroscopy
    Wu Z.-H.
    Huang D.-Z.
    Chen C.-W.
    Mo H.
    Faguang Xuebao/Chinese Journal of Luminescence, 2011, 32 (10): : 1088 - 1092
  • [38] Robotic Manipulation of Human Red Blood Cells with Optical Tweezers for Cell Property Characterization
    Tan, Youhua
    Sun, Dong
    Huang, Wenhao
    Cheng, Jinping
    Cheng, Shuk Han
    IEEE/RSJ 2010 INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2010), 2010, : 4269 - 4274
  • [39] Impact of Nanocapsules on Red Blood Cells Interplay Jointly Assessed by Optical Tweezers and Microscopy
    Avsievich, Tatiana
    Tarakanchikova, Yana
    Zhu, Ruixue
    Popov, Alexey
    Bykov, Alexander
    Skovorodkin, Ilya
    Vainio, Seppo
    Meglinski, Igor
    MICROMACHINES, 2020, 11 (01)
  • [40] Probing orientation and rotation of red blood cells in optical tweezers by Digital Holographic microscopy
    Cardenas, Nelson
    Yu, Lingfeng
    Mohanty, Samarendra K.
    OPTICAL DIAGNOSTICS AND SENSING XI: TOWARD POINT-OF-CARE DIAGNOSTICS AND DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE III, 2011, 7906