Accelerated testing for extended service AMTEC cells

被引:1
|
作者
Svedberg, RC [1 ]
Schaupner, DA [1 ]
Appleby, AJ [1 ]
机构
[1] Adv Modular Power Syst Inc, Ann Arbor, MI 48108 USA
关键词
D O I
10.1109/IECEC.1997.661944
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
AMTEC cells are built with readily available materials, beta"-alumina, stainless steel, Mo, Ta, TiCuNi and TiNi brazes, and TiN electrodes. The long term cell performance is dependent on the stability and inertness of these materials in the high temperature Na environment. The task of selecting materials and verifying that they will perform for long times (15 years for a deep space probe) is addressed. Accelerated testing methods and models to utilize the accelerated test data are being developed. A six and twelve month accelerated test plan to evaluate the BASE/Braze/Electrode/Current Collector (BASE Assembly) interfaces in Na vapor at 1200, 1100, and 1000 K is described. An accelerated wick testing program is also discussed. The as-built BASE assembly braze interfaces have been evaluated. TiN electrodes, exposed for about 4000 hours at 1073 K are examined. This information will illustrate the direction being taken for evaluating lifetest results and developing models for life predictions.
引用
收藏
页码:1230 / 1235
页数:6
相关论文
共 50 条
  • [31] Railcar service spectra generation for full-scale accelerated fatigue testing
    Smith, KB
    Parker, ES
    Iler, DJ
    APPLICATIONS OF AUTOMATION TECHNOLOGY IN FATIGUE AND FRACTURE TESTING AND ANALYSIS, VOL 4, 2002, 1411 : 62 - 84
  • [32] Accelerated weathering testing principles to estimate the service life of organic PV modules
    Haillant, Olivier
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2011, 95 (05) : 1284 - 1292
  • [33] Accelerated Life Testing to Predict Service Life and Reliability for an Appliance Door Hinge
    Cheon, Seunghyeon
    Jeong, Hyunsoo
    Hwang, So Young
    Hong, Seokmoo
    Domblesky, Joseph
    Kim, Naksoo
    43RD NORTH AMERICAN MANUFACTURING RESEARCH CONFERENCE, NAMRC 43, 2015, 1 : 169 - 180
  • [34] Accelerated testing of powerful electrovacuum devices Factors influencing the service life of electrodes
    Lisenkov, A. A.
    Pryalukhin, E. D.
    Kostrin, D. K.
    VAKUUM IN FORSCHUNG UND PRAXIS, 2018, 30 (03) : 36 - 40
  • [35] ACCELERATED TESTING
    不详
    CONCRETE, 1975, 9 (03): : 42 - 42
  • [36] ACCELERATED TESTING
    EVANS, RA
    IEEE TRANSACTIONS ON RELIABILITY, 1991, 40 (05) : 497 - 497
  • [37] Performance analysis of Pluto/Express, multitube AMTEC cells
    Tournier, JM
    El-Genk, MS
    ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (02) : 139 - 173
  • [38] ACCELERATED STRESS-TESTING OF TERRESTRIAL SOLAR-CELLS
    LATHROP, JW
    HAWKINS, DC
    PRINCE, JL
    WALKER, HA
    IEEE TRANSACTIONS ON RELIABILITY, 1982, 31 (03) : 258 - 265
  • [39] Accelerated Membrane Durability Testing of Heavy Duty Fuel Cells
    Macauley, Natalia
    Alavijeh, Alireza Sadeghi
    Watson, Mark
    Kolodziej, Joanna
    Lauritzen, Michael
    Knights, Shanna
    Wang, Gary
    Kjeang, Erik
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2015, 162 (01) : F98 - F107
  • [40] ACCELERATED TESTING OF ADDITIVES IN ZINC PLATES OF NICKEL ZINC CELLS
    BIEGLER, C
    DEUTSCHER, RL
    FLETCHER, S
    HUA, S
    WOODS, R
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1983, 130 (12) : 2303 - 2309