Cph CT Toolbox: A Performance Evaluation

被引:0
|
作者
Bardino, Jonas [1 ]
Rehr, Martin [1 ]
Vinter, Brian [1 ]
机构
[1] Univ Copenhagen, Niels Bohr Inst, eSci Ctr, Blegdamsvej 17, DK-2100 Copenhagen, Denmark
关键词
Computed Tomography; Reconstruction; GPU Performance; PyCUDA; PyOpenCL; RECONSTRUCTION; ALGORITHM; GPU;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
With the first version of the Cph CT Toolbox released and introduced, we turn to intensively evaluating the performance of the FDK and Katsevich reconstruction implementations in the second major release. The evaluation focuses on comparisons between different hardware platforms from the two major GPU compute vendors, AMD and NVIDIA, using our updated CUDA and new OpenCL implementations. Such a performance comparison is in itself interesting in a narrow CT scanning and reconstruction perspective, but it also sheds some light on the performance of those AMD and NVIDIA platforms and GPU technologies: something of general interest to anyone building or considering GPU solutions for their scientific calculations. Results from the best system reveals the chosen streaming strategy to scale linearly up to problem sizes one order of magnitude larger than the available GPU memory, and with only a minor scaling decrease when increasing the problem size further to the next order of magnitude.
引用
收藏
页码:35 / 46
页数:12
相关论文
共 50 条
  • [21] Performance evaluation of the Philips 'Gemini' PET/CT system
    Gregory, R
    Partridge, M
    Flower, MA
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2605 - 2609
  • [22] Design of Anthropomorphic Textured Phantoms for CT Performance Evaluation
    Solomon, Justin
    Bochud, Francois
    Samei, Ehsan
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [23] INITIAL PERFORMANCE EVALUATION OF QUAD I CT SCANNER
    HAQUE, P
    MEDICAL PHYSICS, 1982, 9 (05) : 803 - 803
  • [24] Performance evaluation of a multi-slice CT system
    McCollough, CH
    Zink, FE
    Welch, TJ
    RADIOLOGY, 1999, 210 (02) : 586 - 586
  • [25] Performance evaluation of the temporal response of CT fluoroscopy systems
    Hsieh, J
    RADIOLOGY, 1997, 205 : 319 - 319
  • [26] Performance Evaluation of the Incorporation of PET/CT Procedures in the SUS
    Prates, B.
    Pozzo, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S827 - S828
  • [27] Performance evaluation of abdominal fat burden quantification in CT
    Bandekar, Alok N.
    Naghavi, Morteza
    Kakadiaris, Ioannis A.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 3280 - 3283
  • [28] PET/CT performance evaluation techniques and quality assurance
    Kemp, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2580 - 2581
  • [29] Performance Evaluation of the Discovery NM/CT 670 CZT
    Takahashi, Masafumi
    Miyazaki, Yuuki
    Kondo, Atsushi
    Ehara, Toshihiko
    Koga, Kenji
    Matsunari, Ichiro
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [30] Performance Evaluation of a Prototype Micro-CT System