Current status of medical device malfunction reporting: using end user experience to identify current problems

被引:11
|
作者
Tase, Arkeliana [1 ]
Ni, Melody Z. [1 ]
Buckle, Peter W. [1 ]
Hanna, George B. [1 ]
机构
[1] Imperial Coll, Surg & Canc, London, England
关键词
Continuous quality improvement; Human factors; Incident reporting; Patient safety; Surgery; QUALITATIVE RESEARCH; HEALTH-CARE; SYSTEMS; SAFETY; ERROR; MISS;
D O I
10.1136/bmjoq-2022-001849
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Introduction The current under-reporting of medical device malfunctions, difficulties with the current system and absence of continuous good-quality data has removed the possibility for constant data interrogation and trend recognition to identify evolving issues. This research used end user experiences aiming to understand causes for the lack of data and knowledge on device performance and associated patient risks. This approach was used to identify existing barriers and methods for improvement. Methods This is a qualitative study involving semistructured interviews and surveys with clinicians (15 interviews, 39 surveys) and manufacturers (13 interview participants, 5 surveys). Multiple sources of recruiting were used. Data collected were thematically analysed. Interview results were used to design the surveys. Standards for Reporting Qualitative Research was used. Results Medical device use is based on personal experience rather than evidence which is scarce. Multiple barriers to reporting were identified alongside patient safety and system related aspects. Furthermore, the acceptable level of error was variable as were effects on working practice. Many workarounds have been developed to overcome problems and have become normalised in daily work. These factors were found to have a limiting impact on improvements and learning. Greater system transparency, feedback on submitted reports, a more efficient system of reporting and better communication with manufacturers were reported as some of the required improvements. Conclusions This study has identified numerous complex issues affecting reporting of medical device performance and their subsequent effect on patient safety and clinical staff. The focus on incidents has created many limitations to learning and development. The rich experience of end users should be appropriately used to identify system weaknesses and seek improvement methods. Better communication methods should be developed between healthcare and MedTech (Medical Technologies) industry.
引用
收藏
页数:8
相关论文
共 48 条
  • [41] Experience using preconditioned complex bi-conjugate gradient method with three-dimensional eddy current problems
    Xie, DX
    Yao, YY
    Bai, BD
    Fei, ZY
    Wu, HR
    ELECTROMAGNETIC FIELD PROBLEMS AND APPLICATIONS (ICEF '96), 1997, : 37 - 40
  • [42] Current Status Of In-hospital Cardiac Arrest And Issues Of Collecting Data Using The Latest In-hospital Utstein-style Reporting Templates
    Kanayama, Yu
    Kiguchi, Takeyuki
    Nishiyama, Chika
    Morita, Takashi
    CIRCULATION, 2022, 146
  • [43] What Is the Current Development Status of Wearable Device in Industrial 4.0? Using Technology Acceptance Model to Explore the Willingness and Pattern of Usage of the Consumers
    Liu, Cheng
    Shyu, Chin-Shyang
    Chou, Tsung-Yu
    Chen, Chao-Chien
    Wu, Chien-Hung
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020
  • [44] The Current Status of Suicide and Medical Care System in Japan: An Analysis of 81,407 Patients Using the Diagnosis Procedure Combination Database
    Takeshita, Rina
    Muramatsu, Keiji
    Matsuda, Shinya
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2023, 261 (04): : 291 - 297
  • [45] EXPERIENCE USING A PRECONDITIONED COMPLEX BI-CONJUGATE GRADIENT-METHOD WITH FINITE-ELEMENT EDDY-CURRENT AND ELECTROHEAT PROBLEMS
    LAVERS, JD
    KALAICHELVAN, S
    IEEE TRANSACTIONS ON MAGNETICS, 1985, 21 (06) : 2351 - 2354
  • [46] A Fully Integreated Current-Mode LDO Using PSRC and APSR Technique With-71.8 dB PSRR at 6.78 MHz for Implantable Medical Device
    Sun, Yufei
    Zhang, Ke
    Wang, Jinfu
    An, Fang
    Fan, Xiaoya
    Ma, Yanzhao
    2024 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE, BIOCAS 2024, 2024,
  • [47] Current Status and Management Strategies of Obstetric Hemorrhage Using Contrast-enhanced Dynamic Computed Tomography in a Representative Tertiary Perinatal Medical Center in Japan
    Suzuki, Naohiro
    Chigusa, Yoshitsugu
    Mogami, Haruta
    Komatsu, Maya
    Takakura, Masahito
    Shinozuka, Ken
    Ohtsuru, Shigeru
    Mandai, Masaki
    Kondoh, Eiji
    JMA JOURNAL, 2025, 8 (01): : 242 - 248
  • [48] ROTARY PUMPS FOR POWER-PLANTS USING FOSSIL-FUELS AND FOR NUCLEAR-POWER PLANTS - CURRENT STATUS OF DEVELOPMENT, PLANNING GUIDES, OPERATIONAL EXPERIENCE
    MATTHIAS, HB
    ENERGIETECHNIK, 1984, 34 (04): : 150 - 150