Sequential estimation of creatinine removal by a haemodialyser

被引:0
|
作者
Magalhaes, Felipe Y. [1 ]
Orlande, Helcio R. B. [2 ,3 ]
Suassuna, Jose H. R. [4 ]
机构
[1] Univ Fed Rio de Janeiro, UFRJ, COPPE, Dept Mech Engn, Rio De Janeiro, Brazil
[2] Univ Fed Rio de Janeiro, UFRJ, Politecn COPPE, Dept Mech Engn, Cx Postal 68503, BR-21941972 Rio De Janeiro, RJ, Brazil
[3] Univ Fed Rio de Janeiro, UFRJ, Oncobiol Program, Cx Postal 68503, BR-21941972 Rio De Janeiro, RJ, Brazil
[4] Univ Estado Rio De Janeiro, HUPE Pedro Ernesto Univ Hosp, UERJ, Fac Med Sci,Clin & Acad Unit Nephrol, Rio De Janeiro, Brazil
关键词
State estimation problem; particle filter method; sampling importance resampling algorithm; creatinine; haemodialysis; STATE ESTIMATION; ONLINE; EXCHANGE; MODEL;
D O I
10.1080/17415977.2021.1897123
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work is focused on the transient analysis of a haemodialyser. The objective is to sequentially estimate the concentration of creatinine in the blood returning to the patient, by solving a state estimation problem with measurements of the outflow creatinine concentration in the dialysate. Simulated measurements containing Gaussian errors were used in the inverse analysis, which was based on the Sampling Importance Resampling (SIR) algorithm of the Particle Filter method. Accurate results reveal that this technique may possibly be used for online monitoring and control of the haemodialysis therapy.
引用
收藏
页码:1981 / 2001
页数:21
相关论文
共 50 条
  • [21] ESTIMATION OF CREATININE CLEARANCE IN MALNOURISHED PATIENTS
    LAU, AH
    BERK, SI
    PROSSER, T
    STONICH, T
    CLINICAL PHARMACY, 1988, 7 (01): : 62 - 65
  • [22] Standardization of creatinine determination for clearance estimation
    Hanser, AM
    Hym, B
    Michotey, O
    Gascht, D
    Marchal, A
    Minery, M
    Parent, X
    Capolaghi, B
    ANNALES DE BIOLOGIE CLINIQUE, 2001, 59 (06) : 737 - 742
  • [23] ESTIMATION OF GLOMERULAR FILTRATE BY SERUM CREATININE
    HEIERLI, C
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1972, 97 (10) : 397 - &
  • [24] INTERFERENCE WITH CREATININE ESTIMATION BY A CEPHALOSPORIN AGENT
    HICKMAN, PE
    MCLELLAN, GH
    MASAREI, JRL
    RILEY, WJ
    BOWYER, RC
    BOYNE, P
    MEDICAL JOURNAL OF AUSTRALIA, 1987, 147 (06) : 313 - 314
  • [25] The influence of acetoacetic acid on the estimation of creatinine
    Cathcart, EP
    Orr, JB
    JOURNAL OF PHYSIOLOGY-LONDON, 1914, 48 (06):
  • [26] ESTIMATION OF CREATININE CLEARANCES IN THE MALNOURISHED PATIENTS
    LAU, A
    BERK, S
    PROSSER, T
    STONICH, T
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1988, 11 (01) : A12 - A12
  • [27] Estimation of glomerular filtration rate with creatinine
    Juan Pablo Huidobro, E.
    Tagle, Rodrigo
    Maria Guzman, Ana
    REVISTA MEDICA DE CHILE, 2018, 146 (03) : 344 - 350
  • [28] Catabolism in critical illness: Estimation from urea and creatinine removal during continuous renal replacement therapy (CRRT).
    Leblanc, M
    Garred, LJ
    Pichette, V
    Nolin, L
    Ouimet, D
    Cardinal, J
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 : A1313 - A1313
  • [29] Salivary Creatinine Estimation as an Alternative to Serum Creatinine in Chronic Kidney Disease Patients
    Venkatapathy, Ramesh
    Govindarajan, Vasupradha
    Oza, Nirima
    Parameswaran, Sreejith
    Dhanasekaran, Balamurali Pennagaram
    Prashad, Karthikshree V.
    INTERNATIONAL JOURNAL OF NEPHROLOGY, 2014, 2014
  • [30] Estimation of total daily creatinine clearance in CAPD from serum creatinine concentration
    Jones, CH
    Newstead, CG
    Will, EJ
    PERITONEAL DIALYSIS INTERNATIONAL, 1997, 17 (03): : 250 - 254