Effects of Evaporative Cooling Air Conditioning on Classroom Pollutants and Thermal Environment

被引:0
|
作者
Xiao, Lu [1 ]
Du, Zhenyu [1 ]
机构
[1] Taiyuan Univ Technol, Taiyuan, Shanxi, Peoples R China
来源
关键词
Classroom; carbon dioxide; outlet; indoor environment; ventilation; DISTRIBUTION-SYSTEMS; STRATUM VENTILATION; ULTRAFINE PARTICLES; AIRBORNE PARTICLES; PARTICULATE MATTER; INDOOR; FLOW; PERFORMANCE; BUILDINGS; COMFORT;
D O I
10.1177/11786302221113995
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Indoor particles and carbon dioxide concentration are major indices to evaluate indoor air quality. Based on the two-dimensional filler sieving model of the direct evaporative cooling segment, the porous media model was used for the simulation of the water filler section, the filtering efficiency of particle was simulated by adjusting the water drenching density and airflow velocity in different operating conditions. The three-dimensional classroom model used to change the exhaust outlet position and control the use of air conditioners simulated the indoor thermal environment and the changes in pollutant concentration. The Euler method and Lagrangian method were used to analyze the indoor flow field and particle sieving in the direct evaporation section, respectively. Conclusions show that in the application of evaporative cooling and stratum ventilation air conditioning system in classroom, the position of the exhaust port affects the concentration of carbon dioxide in the student's breathing area. The water filler section can effectively reduce the concentration of particle and carbon dioxide supplied indoors. The filtration efficiency of particle in outdoor air passing through the direct evaporative cooling section based on diffusion, inertial collision, and interception is affected by the combined effect of particle size, onward wind speed, and water spray density. The filtration efficiency of particle increases as the density of the spray water increases. With the increase of head-on wind speed, the filtration efficiency of coarse particulate matter is higher than that of fine particulate matter. The research results help policy makers decide whether to install evaporative cooling air conditioning in schools and determine which exhaust outlet positions are most effective in improving indoor air quality.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] The Control System Design of a Composite Air Conditioning (Evaporative Cooling and Mechanical Refrigeration)
    Qiang, Tian-wei
    Ao, Peng
    2015 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND ARTIFICIAL INTELLIGENCE (CAAI 2015), 2015, : 16 - 21
  • [32] Performance evaluation of a passive air conditioning module integrating radiative sky cooling and indirect evaporative cooling
    Hu, Mingke
    Lee, Poh Seng
    APPLIED THERMAL ENGINEERING, 2024, 244
  • [33] Optimization of Water Consumption in Hybrid Evaporative Cooling Air Conditioning Systems for Data Center Cooling Applications
    Ndukaife, Theodore A.
    Nnanna, A. G. Agwu
    HEAT TRANSFER ENGINEERING, 2019, 40 (07) : 559 - 573
  • [34] Air conditioning of a classroom with solar energy using an absorptive cooling system
    Alaskaree, Ekram Hadi
    ENERGY AND BUILDINGS, 2023, 296
  • [35] THERMAL ENVIRONMENT IN AN AIR-CONDITIONING LABORATORY
    Qiu, Lin
    Guo, Kui
    Wei, Lifeng
    Ren, Geng
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 909 - 914
  • [36] Performance study of a novel indirect evaporative/air-cooled thermoelectric cooling air conditioning system
    Duan, Yujie
    Zhou, Yuanyuan
    Dou, Zhongyu
    Dai, Qiumin
    Yu, Yanshun
    Li, Qiang
    BUILDING AND ENVIRONMENT, 2024, 265
  • [37] THE REAL-TIME MONITORING SYSTEM DESIGN ON EVAPORATIVE COOLING AIR CONDITIONING UNIT
    Qiang Tian-wei
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2012, 30 (01) : 127 - 130
  • [38] A Case Analysis of Application of Evaporative Cooling Air Conditioning of the Communication Equipment Room in Xi'an
    Kun, Fan
    Xiang, Huang
    MECHANICAL SCIENCE AND ENGINEERING IV, 2014, 472 : 231 - 236
  • [39] The real-time monitoring system design on evaporative cooling air conditioning unit
    Tian-wei, Q., 1600, International Information and Engineering Technology Association (30):
  • [40] SPATIOTEMPORAL INVESTIGATION OF EVAPORATIVE COOLING OPTIONS FOR GREENHOUSE AIR-CONDITIONING APPLICATION IN PAKISTAN
    Noor, Shazia
    Ashraf, Hadeed
    Hussain, Ghulam
    Sultan, Muhammad
    Miyazaki, Takahiko
    Shakoor, Aamir
    Mahmood, Muhammad H.
    Riaz, Mahmood
    FRESENIUS ENVIRONMENTAL BULLETIN, 2021, 30 (03): : 2858 - 2870