Utility of fiberoptic bronchoscopy for difficult airway in neonates

被引:7
|
作者
Cobo, Pilar [1 ,2 ]
Vetter-Laracy, Susanne [1 ,2 ]
Beltran, Eva [1 ,2 ]
Antonio Pena-Zarza, Jose [3 ,4 ]
Figuerola, Joan [2 ,3 ]
Osona, Borja [2 ,3 ]
机构
[1] Univ Hosp Son Espases, Dept Pediat, Div Neonatol, Carretera Valldemossa 79, Palma De Mallorca, Spain
[2] Pediat Multidisciplinary Res Grp Balearic Isl Hlt, Palma De Mallorca, Spain
[3] Univ Hosp Son Espases, Div Pediat Resp Med, Dept Pediat, Palma De Mallorca, Spain
[4] Sleep Apneas & Hypopneas Res Grp Balearic Isl Hlt, Palma De Mallorca, Spain
来源
关键词
Difficult airway; extubation; fiberoptic bronchoscopy; intubation; premature newborn; TRACHEAL INTUBATION; MANAGEMENT; CHILDREN; GUIDELINES; REGISTRY; SOCIETY;
D O I
10.1080/14767058.2019.1670801
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: Newborns diagnosed with craniofacial malformations or laryngeal and tracheal alterations may often need advanced airway-management for airway stabilization. Although fiberoptic bronchoscopy (FB) is currently the gold standard for difficult airway management, there is a scarcity of published data on the application of FB in newborns for intubation and controlled extubation (CE). Objectives: This study describes a case series where FB is used for intubation and/or extubation to manage newborns with difficult airway in either urgent procedures or scheduled ones. Methods: All FB were carried out on newborns with difficult airway in the neonatal unit over the period January 2005 to December 2018. Patient characteristics were collected from clinical reports, description of the technique from the procedure report. Results: 66 FBs were performed from a total of 40 newborns, a median age of 25?days and a weight of 3217?g. Eighteen were ex-premature babies (45%). Six (15%) had craniocervical malformations. 17 (25.7%) FBs were performed for tracheal intubation (TI), 6 in emergency situations, 34 (51.5%) for CE, and 15 (22.7%) for precise tube placement. Clearing of the airway was achieved in all cases and thus there were no failed TIs. In 32 cases (94.1%), CE was successfully performed. In 6 cases, withdrawal of the ET midprocedure was decided to postpone as 4 of these required extra treatment prior to renewed extubation attempt and 2 needed a tracheostomy. 2 patients required subsequent FB reintubation due to airway pathology. Complications during the procedure were mild desaturations (3%) and deep desaturations (7.5%). Conclusions: FB is very safe and highly useful when performing intubation in neonates with difficult airway but is essential during extubation to avoid any risk of failure with a potentially fatal outcome. Neonatal units of tertiary hospitals should provide equipment and training to manage these neonates. What is already known? A failed intubation or extubation can lead to cardiac arrest and anoxic brain damage and/or to death in a neonate. Fiberoptic bronchoscopy is recommended as the safest tool for neonates with difficult airway. However, there is little concrete data published in the current literature to support the recommendations. What is new: Fiberoptic bronchoscopy is an essential tool to avoid the risk of a failed extubation in neonates with difficult airway.
引用
收藏
页码:2754 / 2757
页数:4
相关论文
共 50 条
  • [21] FLEXIBLE FIBEROPTIC BRONCHOSCOPY DOES NOT ALTER AIRWAY RESPONSIVENESS
    SODERBERG, M
    LUNDGREN, R
    RESPIRATION, 1989, 56 (3-4) : 182 - 188
  • [22] Fiberoptic bronchoscopy in children using the laryngeal mask airway
    Lesmes, C
    Siplovich, L
    Katz, Y
    PEDIATRIC SURGERY INTERNATIONAL, 2000, 16 (03) : 179 - 181
  • [23] The application of fiberoptic intubation in difficult airway patients
    Liang, Yong X.
    Gu, Miao N.
    Wang, Shi D.
    Chu, Hai C.
    JOURNAL OF CLINICAL ANESTHESIA, 2010, 22 (04) : 300 - 301
  • [24] SOURCES OF VARIATION INFLUENCING AIRWAY RESPONSE TO FIBEROPTIC BRONCHOSCOPY
    PICKENS, FM
    HAYNES, RL
    CHEST, 1977, 72 (03) : 409 - 409
  • [25] AWAKE FIBEROPTIC BRONCHOSCOPY USING THE LARYNGEAL MASK AIRWAY
    BRIMACOMBE, J
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1994, 11 (04) : 339 - 339
  • [26] Comparison of virtual and fiberoptic bronchoscopy in the management of airway stenosis
    Mark, Zsuzsa
    Bajzik, Gabor
    Nagy, Andrea
    Bogner, Peter
    Repa, Imre
    Strausz, Janos
    PATHOLOGY & ONCOLOGY RESEARCH, 2008, 14 (03) : 313 - 319
  • [27] Fiberoptic bronchoscopy in children using the laryngeal mask airway
    C. Lesmes
    L. Siplovich
    Y. Katz
    Pediatric Surgery International, 2000, 16 : 179 - 181
  • [28] Effectiveness of Fiberoptic Intubation in Anticipated Difficult Airway
    Nasir, Khawaja Kamal
    Mansoor, Faraz
    RAWAL MEDICAL JOURNAL, 2005, 30 (02): : 82 - +
  • [29] Utility of fiberoptic bronchoscopy in bone marrow transplant patients
    P White
    JT Bonacum
    CB Miller
    Bone Marrow Transplantation, 1997, 20 : 681 - 687
  • [30] UTILITY OF IMMEDIATE POSTLOBECTOMY FIBEROPTIC BRONCHOSCOPY IN PREVENTING ATELECTASIS
    JAWORSKI, A
    GOLDBERG, SK
    WALKENSTEIN, MD
    WILSON, B
    LIPPMANN, ML
    CHEST, 1988, 94 (01) : 38 - 43