Clinical performance of computer-assisted detection (CAD) system in detecting carcinoma in breasts of different densities

被引:64
|
作者
Ho, WT [1 ]
Lam, PWT [1 ]
机构
[1] Queen Mary Hosp, Dept Radiol, Hong Kong, Hong Kong, Peoples R China
关键词
carcinoma; breast; computer assisted detection; breast density;
D O I
10.1053/crad.2002.1131
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVES: To determine the clinical performance of a computer-assisted detection (CAD) system in detecting carcinoma in breasts of different densities. MATERIALS AND METHODS: A total of 264 sets of bilateral screening mammograms taken in craniocaudal and medial-lateral oblique projections during the year 1997 were divided into four groups according to the BI-RADS density classification: fatty (pattern 1), scattered fibroglandular (pattern 2), heterogeneously dense (pattern 3) and extremely dense (pattern 4). Each group contained about 60% normal and 40% biopsy-proven cancer cases. Of the malignant cases, there were a mixture of mammographic findings including focal masses (<2.5 cm), asymmetrical density, architectural distortion or microcalcifications. Films with artefacts and obvious masses > 2.5 cm were not included. The chosen cases were then digitized and analysed by the CAD system. Sensitivity was calculated as detection of cancer by at least one marker in at least one view. Specificity was calculated as the number of false-positive marks per image on normal cases. Statistical tests of significance were performed by using contingency tables and Chi square test. RESULTS: The CAD system detected 14 out of the total 15 cancer cases in totally fatty breasts with a sensitivity of 93.3% at a specificity of 1.3 false-positive marks per image. In breasts with scattered fibroglandular pattern, the sensitivity was 93.9% (31/33) and the specificity was 1.6 false-positive marks per image while in heterogeneously dense breasts, the sensitivity of the CAD system fell to 84.8% at a specificity of 1.6 false-positive marks per image. The sensitivity of the CAD system further dropped to 64.3% in markedly dense breasts while maintaining a specificity of 1.2 false-positive marks per image. The decrease in sensitivity in dense breast was found to be significant (p = 0.046). CONCLUSION: The sensitivity of the CAD system deteriorated significantly as the density of the breast increased while the specificity of the system remained relatively constant. (C) 2003 The Royal College of Radiologists Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:133 / 136
页数:4
相关论文
共 50 条
  • [21] APPROACH TO QUALITY AND PERFORMANCE CONTROL IN A COMPUTER-ASSISTED CLINICAL-CHEMISTRY LABORATORY
    UNDRILL, PE
    FRAZER, SC
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1979, 32 (02) : 100 - 108
  • [22] Computer-Assisted Evaluation of Contrast Kinetics for Detection of Hepatocellular Carcinoma on Magnetic Resonance Imaging
    Chaturvedi, Abhishek
    Bhargava, Puneet
    Kolokythas, Orpheus
    Mitsumori, Lee M.
    Maki, Jeffrey H.
    [J]. CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2015, 44 (01) : 8 - 14
  • [23] Prognostic value of computer-assisted morphological and morphometrical analysis for detecting the recurrence tendency of basal cell carcinoma
    Cheretis, Christos
    Angelidou, Eirini
    Dietrich, Frank
    Politi, Ekaterini
    Kiaris, Hippokrates
    Koutselini, Helen
    [J]. MEDICAL SCIENCE MONITOR, 2008, 14 (05): : MT13 - MT19
  • [24] Effect of dual-energy subtraction on performance of a commercial computer-assisted diagnosis system in detection of pulmonary nodules
    Siegel, E
    Reiner, B
    Siddiqui, K
    Musk, A
    Wood, S
    Zeng, XL
    Safdar, N
    Nagy, P
    Hooper, F
    Moffitt, R
    Severance, S
    [J]. Medical Imaging 2005: PACS and Imaging Informatics, 2005, 5748 : 392 - 398
  • [25] Implementation of a computer-assisted monitoring system for the detection of adverse drug reactions in gastroenterology
    Dormann, H
    Criegee-Rieck, M
    Neubert, A
    Egger, T
    Levy, M
    Hahn, EG
    Brune, K
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2004, 19 (03) : 303 - 309
  • [26] Computer-assisted orthognathic surgery:: Clinical evaluation of a mandibular condyle repositioning system
    Bettega, G
    Cinquin, P
    Lebeau, J
    Raphaël, B
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 60 (01) : 27 - 34
  • [27] DIAG - A COMPUTER-ASSISTED DERMATOLOGIC DIAGNOSTIC SYSTEM - CLINICAL-EXPERIENCE AND INSIGHT
    HABERMAN, HF
    NORWICH, KH
    DIEHL, DL
    EVANS, SJ
    HARVEY, B
    LANDAU, J
    COBBOLD, RSC
    OBEIRNE, H
    ZINGG, W
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1985, 12 (01) : 132 - 143
  • [28] Computer-Assisted Colonoscopy (the NeoGuide System): Results of the First Human Clinical Trial
    Van Dam, Jacques
    Eickhoff, Axel
    Jakobs, Ralf
    Kudis, Valerie
    Hartmann, Dirk
    Riemann, Jurgen F.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2006, 63 (05) : AB100 - AB100
  • [29] Performance of an Automated Polysomnography Scoring System Versus Computer-Assisted Manual Scoring
    Malhotra, Atul
    Younes, Magdy
    Kuna, Samuel T.
    Benca, Ruth
    Kushida, Clete A.
    Walsh, James
    Hanlon, Alexandra
    Staley, Bethany
    Pack, Allan I.
    Pien, Grace W.
    [J]. SLEEP, 2013, 36 (04) : 573 - 582
  • [30] Mammography reading with computer-aided detection (CAD): Performance of different readers
    Astley, Susan M.
    Duffy, Stephen W.
    Boggis, Caroline R. M.
    Wilson, Mary
    Barr, Nicky B.
    Beetles, Ursula M.
    Griffiths, Miriam A.
    Jain, Anil
    Johnson, Jill
    Roberts, Rita M.
    Deans, Heather
    Duncan, Karen
    Iyengar, Geeta
    Agbaje, Olorunsola
    Griffiths, Pamela M.
    McGee, Magnus A.
    Gillan, Maureen G. C.
    Gilbert, Fiona J.
    [J]. DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 97 - 104