Two-year clinical evaluation of chlorhexidine incorporation in two-step self-etch adhesive

被引:27
|
作者
Araujo, M. S. R. G. [1 ]
Souza, L. C. [1 ]
Apolonio, Fabianni Magalhaes [1 ]
Barros, Livia Oliveira [1 ]
Reis, Alessandra [2 ]
Loguercio, Alessandro Dourado [2 ]
Saboia, V. P. A. [3 ]
机构
[1] Univ Fed Ceara, Fac Pharm Dent & Nursing, Fortaleza, Ceara, Brazil
[2] Univ Estadual Ponta Grossa, Sch Dent, Dept Restorat Dent, Ponta Grossa, Parana, Brazil
[3] Univ Fed Ceara, Fac Pharm Dent & Nursing, Dept Restorat Dent, Fortaleza, Ceara, Brazil
关键词
Chlorhexidine; Self-etch adhesive system; Non-carious cervical lesions (NCCLs); Clinical trials; MATRIX METALLOPROTEINASES; RESIN HYDROPHILICITY; CONTAINING ACID; WATER SORPTION; HYBRID LAYER; ONE-STEP; DENTIN; DURABILITY; RINSE; DEGRADATION;
D O I
10.1016/j.jdent.2014.07.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this 24-month double-blind randomized paired-tooth clinical study was to evaluate the 2-year clinical performance of two self-etch adhesives containing or not chlorhexidine digluconate (CHX) in non-carious cervical lesions (NCCLs). Methods: Twenty-two patients, with at least four NCCLs, participated in this study. After sample size calculation, 126 restorations were assigned to one of the following groups: CSE - Clearfil SE Bond (Kuraray); CSE/CHX - Clearfil SE Bond + CHX; ADS - AdheSE (Ivoclar Vivadent); and ADS/CHX - AdheSE + CHX. The composite resin Filtek Z-250 composite (3 M ESPE) was placed incrementally by one expert operator. The restorations were evaluated at baseline and after 2 years using the modified USPHS criteria. Statistical analyses were performed with Friedman repeated measures ANOVA by rank and Fisher exact test for significance in each pair (alpha = 0.05). Results: No significant difference was observed between baseline and 2-year for any criteria when adhesives with and without the addition of CHX were compared (p > 0.05). ADS and ADS/CHX resulted in lower retention rates (82% on average) than CSE and CSE/CHX (97%) (p = 0.02). Conclusions: The inclusion of CHX into the primer of both self-etch systems did not add clinical advantages over the 2-year period. Clearfil SE Bond resulted in better retention rate than AdheSE. Clinical significance: It is more important to choose a gold standard self-etch adhesive, like a Clearfil SE Bond, than to consider the inclusion of CHX in the self-etch adhesives. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 50 条
  • [1] Clinical Evaluation of a Two-step Etch&Rinse and a Two-step Self-etch Adhesive System in Class II Restorations: Two-year Results
    Ermis, R. B.
    Kam, O.
    Celik, E. U.
    Temel, U. B.
    [J]. OPERATIVE DENTISTRY, 2009, 34 (06) : 656 - 663
  • [2] Two-year clinical evaluation of proanthocyanidins added to a two-step etch-and-rinse adhesive
    de Souza, Lidiane Costa
    Rodrigues, Nara Sousa
    Cunha, Diana Araujo
    Feitosa, Victor Pinheiro
    Santiago, Sergio Lima
    Reis, Alessandra
    Loguercio, Alessandro Dourado
    Matos, Thalita de Paris
    Aragao Saboia, Vicente de Paulo
    Perdigao, Jorge
    [J]. JOURNAL OF DENTISTRY, 2019, 81 : 7 - 16
  • [3] Three-year clinical effectiveness of a two-step self-etch adhesive in cervical lesions
    Peumans, M
    De Munck, J
    Van Landuyt, K
    Lambrechts, P
    Van Meerbeek, B
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2005, 113 (06) : 512 - 518
  • [4] Two-year clinical effectiveness of a self-etch adhesive in cervical lesions.
    Peumans, M.
    Van Meerbeek, B.
    De Munck, J.
    Lambrechts, P.
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 : B126 - B126
  • [5] Evaluation of alternative photoinitiator systems in two-step self-etch adhesive systems
    Almeida, Suzanne M.
    Meereis, Carine T. W.
    Leal, Fernanda B.
    Carvalho, Rodrigo, V
    Boeira, Peterson O.
    Chisini, Luiz A.
    Cuevas-Suarez, Carlos E.
    Lima, Giana S.
    Piva, Evandro
    [J]. DENTAL MATERIALS, 2020, 36 (02) : E29 - E37
  • [6] A Randomized Clinical Evaluation of a One- and Two-step Self-etch Adhesive Over 24 Months
    Loguercio, A. D.
    Manica, D.
    Ferneda, F.
    Zander-Grande, C.
    Amaral, R.
    Stanislawczuk, R.
    Carvalho, R. M.
    Manso, A.
    Reis, A.
    [J]. OPERATIVE DENTISTRY, 2010, 35 (03) : 265 - 272
  • [7] Clinical Evaluation of Self-etch and Total-etch Adhesive Systems in Noncarious Cervical Lesions: A Two-year Report
    Burgess, J. O.
    Sadid-Zadeh, R.
    Cakir, D.
    Ramp, L. C.
    [J]. OPERATIVE DENTISTRY, 2013, 38 (05) : 477 - 487
  • [8] Bond strengths of one- and two-step self-etch adhesive systems
    Knobloch, Lisa A.
    Gailey, David
    Azer, Shereen
    Johnston, William M.
    Clelland, Nancy
    Kerby, Ronald E.
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (04): : 216 - 222
  • [9] One-year clinical evaluation of a two-step self-etch adhesive with and without additional enamel etching technique in cervical lesions
    Ozel, E.
    Say, E. C.
    Yurdaguven, H.
    Soyman, M.
    [J]. AUSTRALIAN DENTAL JOURNAL, 2010, 55 (02) : 156 - 161
  • [10] A three-year clinical evaluation of a one-step self-etch and a two-step etch-and-rinse adhesive in non-carious cervical lesions
    Haefer, Matthias
    Jentsch, Holger
    Haak, Rainer
    Schneider, Hartmut
    [J]. JOURNAL OF DENTISTRY, 2015, 43 (03) : 350 - 361