Bond strengths of one- and two-step self-etch adhesive systems

被引:65
|
作者
Knobloch, Lisa A. [1 ]
Gailey, David [1 ]
Azer, Shereen [1 ]
Johnston, William M. [1 ]
Clelland, Nancy [1 ]
Kerby, Ronald E. [1 ]
机构
[1] Ohio State Univ, Coll Dent, Columbus, OH 43210 USA
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2007年 / 97卷 / 04期
关键词
D O I
10.1016/j.prosdent.2007.02.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. One-bottle self-etching adhesives have been introduced that combine the etchant, primer, and adhesive into a single bottle in an effort to reduce the number of bonding steps. Limited research has been conducted comparing the efficacy of 1-bottle and 2-bottle self-etching adhesives. Purpose. This investigation evaluated the microtensile bond strength (MTBS) of 3 one-step self-etching adhesives, 2 two-step self-etching adhesives, and a total-etch adhesive. A secondary objective was to evaluate the effect of an intermediary layer of elastic resin on the MTBS of 2 of the self-etching adhesives. Material and methods. The MTBS of 3 one-step self-etching adhesives (G-Bond, iBond, and Clearfil S-3),2 two-step self-etching adhesives (Clearfil SE and Optibond Solo Plus Self-Etch), and a total-etch adhesive (Prime & Bond NT) was evaluated. Microtensile bond strength (MPa) was determined using composite resin (Herculite XRV) cylinders bonded to the dentin surface of human third molars (n=24) using 6 bonding agents. Each bonded tooth specimen was longitudinally sectioned to produce bar-shaped specimens with a square cross-sectional nominal bond area of 1.4 mm(2) (n=20). Bonded specimens were stored in distilled water at 37 degrees C +/- 2 degrees C for 72 hours, during which time they were subjected to thermal cycling (1500 cycles, in water baths of 5 degrees C and 55 degrees C, for a dwell time of 30 seconds). Testing was performed on a universal testing machine at a crosshead speed of 1.0 mm/min. One-way ANOVA, Ryan-Einot-Gabriel-Welsh multiple range test, and Wald chi square test, each using an overall alpha=.05, were performed on all data. Low-power (X20) microscopic examination of the bond failure was observed for each specimen. Results. The 1-way ANOVA (P <.001) and Ryan-Einot-Gabriel-Welsh multiple range test (P <.05) showed significant differences between the mean MTBS values for several of the bonding agents tested. The Wald chi square test of the Weibull distribution showed significant differences between adhesives (P <.001). Conclusion. Of the bonding agents tested, significantly higher MTBS was obtained with the total-etch 2-stage adhesive. The results of this stud), suggest that there are similar bond strengths between the 1- and 2-bottle self-etch adhesives.
引用
收藏
页码:216 / 222
页数:7
相关论文
共 50 条
  • [1] Microleakage assessment of one- and two-step self-etch adhesive systems with the low shrinkage composites
    Hoseinifar, Razieh
    Kermanshah, Hamid
    [J]. JOURNAL OF ORAL HEALTH AND ORAL EPIDEMIOLOGY, 2015, 4 (02): : 71 - 79
  • [2] Microtensile bond strengths of one- and two-step self-etch adhesives to bur-cut enamel and dentin
    De Munck, J
    Van Meerbeek, B
    Satoshi, I
    Vargas, M
    Yoshida, Y
    Armstrong, S
    Lambrechts, P
    Vanherle, G
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2003, 16 (06): : 414 - 420
  • [3] A Randomized Clinical Evaluation of a One- and Two-step Self-etch Adhesive Over 24 Months
    Loguercio, A. D.
    Manica, D.
    Ferneda, F.
    Zander-Grande, C.
    Amaral, R.
    Stanislawczuk, R.
    Carvalho, R. M.
    Manso, A.
    Reis, A.
    [J]. OPERATIVE DENTISTRY, 2010, 35 (03) : 265 - 272
  • [4] Evaluation of alternative photoinitiator systems in two-step self-etch adhesive systems
    Almeida, Suzanne M.
    Meereis, Carine T. W.
    Leal, Fernanda B.
    Carvalho, Rodrigo, V
    Boeira, Peterson O.
    Chisini, Luiz A.
    Cuevas-Suarez, Carlos E.
    Lima, Giana S.
    Piva, Evandro
    [J]. DENTAL MATERIALS, 2020, 36 (02) : E29 - E37
  • [5] Bond strengths of two-step and one-step adhesive systems
    Kelsey, WP
    Triolo, PT
    Blankenau, RJ
    Kelsey, MN
    Hauser, D
    Ortmeier, C
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1922 - 1922
  • [6] Effect of Desensitizing Agents on the Microtensile Bond Strength of a Two-step Self-etch Adhesive to Dentin
    Arisu, H. D.
    Dalkihc, E.
    Uctasli, M. B.
    [J]. OPERATIVE DENTISTRY, 2011, 36 (02) : 153 - 161
  • [7] Influence of thermal cycling on dentin bond strengths of single-step self-etch adhesive systems
    Asaka, Y.
    Amano, S.
    Rikuta, A.
    Kurokawa, H.
    Miyazaki, M.
    Platt, J. A.
    Moore, B. K.
    [J]. OPERATIVE DENTISTRY, 2007, 32 (01) : 73 - 78
  • [8] Micro-tensile bond strength (pTBS) of one- and two-step self-etch adhesives to enamel and dentin.
    De Munck, J
    Van Meerbeck, B
    Inoue, S
    Lambrechts, P
    Vanherle, G
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : B276 - B276
  • [9] Microtensile bond strengths for six 2-step and two 1-step self-etch adhesive systems to enamel and dentin
    Reis, Alessandra
    Loguercio, Alessandro Dourado
    Manso, Adriana Pigozzo
    Miranda Grande, Rosa Helena
    Schiltz-Taing, Michelle
    Suh, Byoung
    Chen, Liang
    Carvalho, Ricardo Marins
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2013, 26 (01): : 44 - 50
  • [10] Polymerization behavior within adhesive layer of one- and two-step self-etch adhesives: A micro-Raman spectroscopic study
    Sakano, Wakae
    Nakajima, Masatoshi
    Prasansuttiporn, Taweesak
    Foxton, Richard M.
    Tagami, Junji
    [J]. DENTAL MATERIALS JOURNAL, 2013, 32 (06) : 992 - 998