Determination of d and q reactances of permanent-magnet synchronous motors without measurements of the rotor position

被引:62
|
作者
Nee, HP [1 ]
Lefevre, L [1 ]
Thelin, P [1 ]
Soulard, J [1 ]
机构
[1] Royal Inst Technol, KTH, Dept Elect Power Engn, SE-10044 Stockholm, Sweden
关键词
dq model; permanent-magnet machine; power factor; synchronous reactances;
D O I
10.1109/28.871281
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The interest in permanent-magnet synchronous motors:(PMSMs) is increasing in a wide area of applications. Since most PMSMs will operate without a shaft sensor in the future, valuable: information for experimental determination of machine parameters will be lost,In this paper, therefore, a method is presented where the induced EMF and the d-axis reactance are determined in a no-load test and the q-axis reactance is determined in a load test. The load angle delta is determined from the load test by means of a new analytical method. In this way, no separate measurement of the load angle is required. The method is especially suitable for line-start PMSMs which normally operate with negative d-axis current and, therefore, are not saturated in the d-axis flux paths. Moreover, the method is very simple to carry out for any laboratory technician, since the only tests that have to be made are standard tests which are made on standard induction motors on a regular basis.
引用
收藏
页码:1330 / 1335
页数:6
相关论文
共 50 条
  • [41] DYNAMIC INSTABILITY IN PERMANENT-MAGNET SYNCHRONOUS STEPPING MOTORS
    PICKUP, IED
    RUSSELL, AP
    IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1987, 134 (02): : 91 - 100
  • [42] Technique of evolutionary optimization permanent-magnet synchronous motors
    Kuznetcov, V. A.
    Zykov, N. V.
    Ivanov, M. M.
    XII INTERNATIONAL SYMPOSIUM INTELLIGENT SYSTEMS 2016, (INTELS 2016), 2017, 103 : 198 - 204
  • [43] Multiphysics design methodology of permanent-magnet synchronous motors
    Makni, Z.
    Besbes, M.
    Marchand, C.
    IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2007, 56 (04) : 1524 - 1530
  • [44] TORQUE RIPPLE ATTENUATION IN PERMANENT-MAGNET SYNCHRONOUS MOTORS
    CARLSON, R
    TAVARES, AA
    BASTOS, JP
    LAJOIEMAZENC, M
    CONFERENCE RECORD OF THE 1989 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, PTS 1-2, 1989, : 57 - 62
  • [45] Monitoring the thermal condition of permanent-magnet synchronous motors
    Milanfar, P
    Lang, JH
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1996, 32 (04) : 1421 - 1429
  • [46] FIELD CIRCUIT ANALYSIS OF PERMANENT-MAGNET SYNCHRONOUS MOTORS
    ZHOU, P
    RAHMAN, MA
    JABBAR, MA
    IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (04) : 1350 - 1359
  • [47] Enhanced modeling of linear permanent-magnet synchronous motors
    Vaez-Zadeh, S.
    Isfahani, A. Hassanpour
    IEEE TRANSACTIONS ON MAGNETICS, 2007, 43 (01) : 33 - 39
  • [48] Sensorless velocity control of permanent-magnet synchronous motors
    Shouse, KR
    Taylor, DG
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 1998, 6 (03) : 313 - 324
  • [49] Iron loss model for permanent-magnet synchronous motors
    Roshen, Waseem
    IEEE TRANSACTIONS ON MAGNETICS, 2007, 43 (08) : 3428 - 3434
  • [50] Sensorless position estimation and control of permanent-magnet synchronous motors using a saturation model
    Jebai, Al Kassem
    Malrait, Francois
    Martin, Philippe
    Rouchon, Pierre
    INTERNATIONAL JOURNAL OF CONTROL, 2016, 89 (03) : 535 - 549