Clinical feasibility of 90Y digital PET/CT for imaging microsphere biodistribution following radioembolization

被引:17
|
作者
Wright, Chadwick L. [1 ]
Binzel, Katherine [1 ]
Zhang, Jun [1 ]
Wuthrick, Evan J. [2 ]
Knopp, Michael V. [1 ]
机构
[1] Ohio State Univ, Dept Radiol, Wright Ctr Innovat Biomed Imaging, Wexner Med Ctr, 395 W 12th Ave,Room 430,4th Floor, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Radiat Oncol, Wexner Med Ctr, Columbus, OH 43210 USA
基金
美国国家卫生研究院;
关键词
Digital PET/CT; Y-90 microsphere radioembolization; Assessment of biodistribution; BREMSSTRAHLUNG SPECT/CT; TOF PET;
D O I
10.1007/s00259-017-3694-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the clinical feasibility of next generation solid-state digital photon counting PET/CT (dPET/CT) technology and imaging findings in patients following Y-90 microsphere radioembolization in comparison with standard of care (SOC) bremsstrahlung SPECT/CT (bSPECT/CT). Five patients underwent SOC Y-90 bremsstrahlung imaging immediately following routine radioembolization with 3.5 +/- 1.7 GBq of Y-90-labeled glass microspheres. All patients also underwent dPET/CT imaging at 29 +/- 11 h following radioembolization. Matched pairs comparison was used to compare image quality, image contrast and Y-90 biodistribution between dPET/CT and bSPECT/CT images. Volumetric assessments of Y-90 activity using different isocontour thresholds on dPET/CT and bSPECT/CT images were also compared. Digital PET/CT consistently provided better visual image quality and Y-90-to-background image contrast while depicting Y-90 biodistribution than bSPECT/CT. Isocontour volumetric assessment using a 1% threshold precisely outlined Y-90 activity and the treatment volume on dPET/CT images, whereas a more restrictive 20% threshold on bSPECT/CT images was needed to obtain comparable treatment volumes. The use of a less restrictive 10% threshold isocontour on bSPECT/CT images grossly overestimated the treatment volume when compared with the 1% threshold on dPET/CT images. Digital PET/CT is clinically feasible for the assessment of Y-90 microsphere biodistribution following radioembolization, and provides better visual image quality and image contrast than routine bSPECT/CT with comparable acquisition times. With further optimization and clinical validation, dPET technology may allow faster and more accurate imaging-based assessment of Y-90 microsphere biodistribution.
引用
收藏
页码:1194 / 1197
页数:4
相关论文
共 50 条
  • [41] Clinical Follow-up after Imaging and Dosimetry for Yttrium-90 (90Y) Liver Radioembolization Using a SiPM-based PET/CT Scanner
    Duan, H.
    Khalaf, M. H.
    Baratto, L.
    Srinivas, S.
    Sze, D.
    Iagaru, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S259 - S259
  • [42] Clinical Follow-Up after Imaging and Dosimetry for Yttrium-90 (90Y) Liver Radioembolization Using a SiPM-Based PET/CT Scanner
    Duan, Heying
    Khalaf, Mohamed
    Baratto, Lucia
    Srinivas, Shyam
    Sze, Daniel
    Iagaru, Andrei
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [43] High quality imaging and dosimetry for yttrium-90 (90Y) liver radioembolization using a SiPM-based PET/CT scanner
    Heying Duan
    Mohamed H. Khalaf
    Valentina Ferri
    Lucia Baratto
    Shyam M. Srinivas
    Daniel Y. Sze
    Andrei Iagaru
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 2426 - 2436
  • [44] High quality imaging and dosimetry for yttrium-90 (90Y) liver radioembolization using a SiPM-based PET/CT scanner
    Duan, Heying
    Khalaf, Mohamed H.
    Ferri, Valentina
    Baratto, Lucia
    Srinivas, Shyam M.
    Sze, Daniel Y.
    Iagaru, Andrei
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (08) : 2426 - 2436
  • [45] Comparison of three voxel-level dosimetry methods for 90Y-microsphere radioembolization based on PET/CT imaging
    Hu, Hai
    Liang, Ziwei
    Liu, Hui
    Dai, Tiantian
    Wei, Qingyang
    Jiao, Fang
    Liu, Yaqiang
    He, Zuo-Xiang
    Wu, Jing
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [46] Sequential FDG PET/CT in 90Y microsphere treatment of unresectable colorectal liver metastases
    Maren Bienert
    Barry McCook
    Brian I. Carr
    David A. Geller
    Mike Sheetz
    Nikhil Amesur
    Norbert Avril
    European Journal of Nuclear Medicine and Molecular Imaging, 2005, 32 : 723 - 723
  • [47] Sequential FDG PET/CT in 90Y microsphere treatment of unresectable colorectal liver metastases
    Bienert, M
    McCook, B
    Carr, BI
    Geller, DA
    Sheetz, M
    Amesur, N
    Avril, N
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (06) : 723 - 723
  • [48] Imaging 90Y distribution with PET: system performance and clinical use
    D'Ambrosio, L.
    Arrichiello, C.
    Aurilio, M.
    Morisco, A.
    Prisco, A.
    Giordano, A.
    Chiaramida, P.
    Di Gennaro, F.
    Caraco', C.
    Lastoria, S.
    Aloj, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S200 - S200
  • [49] FDG PET/CT as a Prognostic Test After 90Y Radioembolization in Patients With Metastatic Hepatic Disease
    Zalom, Martina
    Yu, Run
    Friedman, Marc
    Bresee, Catherine
    Waxman, Alan
    CLINICAL NUCLEAR MEDICINE, 2012, 37 (09) : 862 - 865
  • [50] A multicentre comparison of quantitative 90Y PET/CT for dosimetric purposes after radioembolization with resin microspheres
    Willowson, Kathy P.
    Tapner, Michael
    Bailey, Dale L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (08) : 1202 - 1222