Clinical feasibility of 90Y digital PET/CT for imaging microsphere biodistribution following radioembolization

被引:17
|
作者
Wright, Chadwick L. [1 ]
Binzel, Katherine [1 ]
Zhang, Jun [1 ]
Wuthrick, Evan J. [2 ]
Knopp, Michael V. [1 ]
机构
[1] Ohio State Univ, Dept Radiol, Wright Ctr Innovat Biomed Imaging, Wexner Med Ctr, 395 W 12th Ave,Room 430,4th Floor, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Radiat Oncol, Wexner Med Ctr, Columbus, OH 43210 USA
基金
美国国家卫生研究院;
关键词
Digital PET/CT; Y-90 microsphere radioembolization; Assessment of biodistribution; BREMSSTRAHLUNG SPECT/CT; TOF PET;
D O I
10.1007/s00259-017-3694-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the clinical feasibility of next generation solid-state digital photon counting PET/CT (dPET/CT) technology and imaging findings in patients following Y-90 microsphere radioembolization in comparison with standard of care (SOC) bremsstrahlung SPECT/CT (bSPECT/CT). Five patients underwent SOC Y-90 bremsstrahlung imaging immediately following routine radioembolization with 3.5 +/- 1.7 GBq of Y-90-labeled glass microspheres. All patients also underwent dPET/CT imaging at 29 +/- 11 h following radioembolization. Matched pairs comparison was used to compare image quality, image contrast and Y-90 biodistribution between dPET/CT and bSPECT/CT images. Volumetric assessments of Y-90 activity using different isocontour thresholds on dPET/CT and bSPECT/CT images were also compared. Digital PET/CT consistently provided better visual image quality and Y-90-to-background image contrast while depicting Y-90 biodistribution than bSPECT/CT. Isocontour volumetric assessment using a 1% threshold precisely outlined Y-90 activity and the treatment volume on dPET/CT images, whereas a more restrictive 20% threshold on bSPECT/CT images was needed to obtain comparable treatment volumes. The use of a less restrictive 10% threshold isocontour on bSPECT/CT images grossly overestimated the treatment volume when compared with the 1% threshold on dPET/CT images. Digital PET/CT is clinically feasible for the assessment of Y-90 microsphere biodistribution following radioembolization, and provides better visual image quality and image contrast than routine bSPECT/CT with comparable acquisition times. With further optimization and clinical validation, dPET technology may allow faster and more accurate imaging-based assessment of Y-90 microsphere biodistribution.
引用
收藏
页码:1194 / 1197
页数:4
相关论文
共 50 条
  • [1] Clinical feasibility of 90Y digital PET/CT for imaging microsphere biodistribution following radioembolization
    Chadwick L. Wright
    Katherine Binzel
    Jun Zhang
    Evan J. Wuthrick
    Michael V. Knopp
    European Journal of Nuclear Medicine and Molecular Imaging, 2017, 44 : 1194 - 1197
  • [2] 90Y Digital PET/CT Imaging Following Radioembolization
    Wright, Chadwick L.
    Zhang, Jun
    Binzel, Katherine
    Wuthrick, Evan J.
    Knopp, Michael V.
    CLINICAL NUCLEAR MEDICINE, 2016, 41 (12) : 975 - 976
  • [3] 90Y TIME-OF-FLIGHT PET/CT IS SUPERIOR TO BREMSSTRAHLUNG SPECT/CT FOR POST-RADIOEMBOLIZATION IMAGING OF MICROSPHERE BIODISTRIBUTION
    Kao, Y.
    Tan, E.
    Lim, K.
    Ng, C.
    Goh, S.
    INTERNAL MEDICINE JOURNAL, 2011, 41 : 44 - 44
  • [4] PET/CT Specificities in 90Y Imaging Post Radioembolization
    Stephan, Walrand
    Michel, Hesse
    PET CLINICS, 2019, 14 (04) : 469 - +
  • [5] STATE-OF-THE-ART IMAGING OF POST-RADIOEMBOLIZATION 90Y MICROSPHERE BIODISTRIBUTION USING 90Y TIME-OF-FLIGHT PET/CT: EARLY SINGAPORE EXPERIENCE
    Kao, Y.
    Tan, E.
    Thang, S.
    Magsombol, B.
    Lim, K.
    Somaesan, S.
    Chow, P.
    Ng, C.
    Goh, S.
    INTERNAL MEDICINE JOURNAL, 2011, 41 : 13 - 13
  • [6] Comparative analysis of 90Y Bremsstrahlung SPECT/CT and 90Y PET/CT imaging of 90Y microsphere therapy
    Rangarajan, V.
    Zade, A.
    Jha, A.
    Singh, A.
    Shah, S.
    Agrawal, A.
    Purandare, N.
    Shetty, N.
    Kulkarni, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S312 - S312
  • [7] 90Y microsphere therapy: does 90Y PET/CT imaging obviate the need for 90Y Bremsstrahlung SPECT/CT imaging?
    Zade, Anand A.
    Rangarajan, Venkatesh
    Purandare, Nilendu C.
    Shah, Sneha A.
    Agrawal, Archi R.
    Kulkarni, Suyash S.
    Shetty, Nitin
    NUCLEAR MEDICINE COMMUNICATIONS, 2013, 34 (11) : 1090 - 1096
  • [8] 90Y Microsphere Hepatic Distribution Can Be Evaluated Following Radioembolization With PET/MRI
    Speirs, C. K.
    Benegal, A.
    Fowler, K. J.
    Olsen, J. R.
    Saad, N.
    Sharma, A.
    Garcia-Ramirez, J.
    Laforest, R.
    Parikh, P. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S320 - S320
  • [9] Liver Dose Calculation for 90Y Radioembolization with PET/CT
    Yu, N.
    Xia, P.
    MEDICAL PHYSICS, 2012, 39 (06) : 3695 - 3695
  • [10] Evaluating 90Y PET/CT Imaging
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (01) : 19N - 19N