摘要
It is important to accurately monitor residual cardiac function in patients under long-term continuous-flow left ventricular assist device (cfLVAD) support. Two new measures of left ventricular (LV) chamber contractility in the cfLVAD-unloaded ventricle include I-Q, a regression coefficient between maximum flow acceleration and flow pulsatility at different pump speeds; and K, a logarithmic relationship between volumes moved in systole and diastole. We sought to optimize these indices. We also propose RIQ, a ratio between maximum flow acceleration and flow pulsatility at baseline pump speed, as an alternative to I-Q. Eleven patients (mean age 49 +/- 11 years) were studied. The K index was derived at baseline pump speed by defining systolic and diastolic onset as time points at which maximum and minimum volumes move through the pump. I-Q across the full range of pump speeds was markedly different between patients. It was unreliable in three patients with underlying atrial fibrillation (coefficient of determination R-2 range: 0.38-0.74) and also when calculated without pump speed manipulation (R-2 range: 0.01-0.74). The K index was within physiological ranges, but poorly correlated to both I-Q (P=0.42) and RIQ (P=0.92). In four patients there was excellent correspondence between RIQ and I-Q, while four other patients showed a poor relationship between these indices. As RIQ does not require pump speed changes, it may be a more clinically appropriate measure. Further studies are required to determine the validity of these indices.
引用
收藏
页码:1029 / 1034
页数:6
相关论文
共 50 条
  • [31] Complete coronary thrombolysis on continuous-flow left ventricular assist device
    Ichihara, Yuki
    Hamasaki, Azumi
    Saito, Satoshi
    Niinami, Hiroshi
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2021, 60 (03) : 721 - 721
  • [32] Continuous-Flow Left Ventricular Assist Device Thrombosis: A Solvable Problem
    Pagani, Francis D.
    ASAIO JOURNAL, 2016, 62 (01) : 3 - 5
  • [33] What Is the Optimal Setting for a Continuous-Flow Left Ventricular Assist Device in Severe Mitral Regurgitation?
    Naito, Noritsugu
    Nishimura, Takashi
    Takewa, Yoshiaki
    Kishimoto, Satoru
    Date, Kazuma
    Umeki, Akihide
    Ando, Masahiko
    Ono, Minoru
    Tatsumi, Eisuke
    ARTIFICIAL ORGANS, 2016, 40 (11) : 1039 - 1045
  • [34] What is an Optimal Setting of Continuous-flow Left Ventricular Assist Device for Severe Mitral Regurgitation?
    Naito, Noritsugu
    Nishimura, Takashi
    Kishimoto, Satoru
    Takewa, Yoshiaki
    Ono, Minoru
    Tatsumi, Eisuke
    CIRCULATION, 2015, 132
  • [35] Post-cardiac transplant survival after support with a continuous-flow left ventricular assist device: Impact of duration of left ventricular assist device support and other variables
    John, Ranjit
    Pagani, Francis D.
    Naka, Yoshifumi
    Boyle, Andrew
    Conte, John V.
    Russell, Stuart D.
    Klodell, Charles T.
    Milano, Carmelo A.
    Rogers, Joseph
    Farrar, David J.
    Frazier, O. Howard
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (01): : 174 - 181
  • [36] Pathology of aortic valve remodeling after continuous-flow left ventricular assist device support
    van Rijswijk, Jan Willem
    Vink, Aryan
    Martina, Jerson R.
    Ramjankhan, Faiz Z.
    Goldschmeding, Roel
    de Jonge, Nicolaas
    Kluin, Jolanda
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (01): : 113 - 116
  • [37] Gender differences in the risk of stroke during support with continuous-flow left ventricular assist device
    Morris, Alanna A.
    Pekarek, Ann
    Wittersheim, Kris
    Cole, Robert T.
    Gupta, Divya
    Duc Nguyen
    Laskar, S. Raja
    Butler, Javed
    Smith, Andrew
    Vega, J. David
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (12): : 1570 - 1577
  • [38] Prolonged continuous-flow left ventricular assist device support and posttransplantation outcomes: A new challenge
    Fukuhara, Shinichi
    Takeda, Koji
    Polanco, Antonio R.
    Takayama, Hiroo
    Naka, Yoshifumi
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (03): : 872 - +
  • [39] Long-term outcome of patients on continuous-flow left ventricular assist device support
    Takeda, Koji
    Takayama, Hiroo
    Kalesan, Bindu
    Uriel, Nir
    Colombo, Paolo C.
    Jorde, Ulrich P.
    Naka, Yoshifumi
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (04): : 1606 - 1614
  • [40] Increased Aortic Vascular Fibrosis with Prolonged Continuous-Flow Left Ventricular Assist Device Support
    Dobrinskikh, E.
    Purohit, S.
    Dodson, R.
    Shtofman, R.
    Al-Juboori, S.
    Aftab, M.
    Reece, T.
    Cornwell, W.
    Ambardekar, A. V.
    Colorado, U.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S125 - S126