The influence of polyatomic primary ion chemistry on matrix effects in secondary ion mass spectrometry analysis

被引:7
|
作者
Alnajeebi, Afnan M. [1 ,2 ]
Vickerman, John C. [1 ,3 ]
Lockyer, Nicholas P. [1 ,2 ]
机构
[1] Univ Manchester, Manchester Inst Biotechnol, 131 Princess St, Manchester M1 7DN, Lancs, England
[2] Univ Manchester, Sch Chem, Oxford Rd, Manchester M13 9PL, Lancs, England
[3] Univ Manchester, Sch Chem Engn & Analyt Sci, Oxford Rd, Manchester M13 9PL, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
CLUSTER PRIMARY BEAMS; METAL-ASSISTED SIMS; TOF-SIMS; BIOLOGICAL CELLS; BRAIN-TISSUE; AMINO-ACIDS; GAS-PHASE; TIME; YIELDS; ARGON;
D O I
10.1002/rcm.8265
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RationaleMethodsThe application of mass spectrometry imaging techniques to determine two- (2D) and three- (3D) dimensional chemical distribution ideally provides uniform, high sensitivity to multiple components and reliable quantification. These criteria are typically not met due to variations in sensitivity due to the chemistry of the analyte and surrounding surface chemistry. Here we explore the influence of projectile beam chemistry and sample chemistry in time-of-flight secondary ion mass spectrometry (TOF-SIMS). To the authors' knowledge this is the first time the combined effects of projectile chemistry and sample environment on the quantitative determination of mixed samples have been systematically studied. Secondary ion yields of lipid and amino acid mixtures were measured under 20keV C-60, Ar-n, and (H2O)(n) cluster ion bombardment (n=2000 or 4000) using TOF-SIMS. Ion suppression/enhancement effects were studied in dry sample films and in trehalose and water ice matrices. ResultsConclusionsThe extent of the matrix effects and the secondary ion yield were found to depend on the chemistry of the primary ion beam and (for C-60, Ar-n) on the nature of the sample matrix. Under (H2O)(n) bombardment the sample matrix had negligible effect on the analysis. Compared with C-60 and Ar-n, water-containing cluster projectiles enhanced the sensitivity of TOF-SIMS determination of the chosen analytes and reduced the effect of signal suppression/enhancement in multicomponent samples and in different sample matrices. One possible explanation for this is that the (H2O)(4000) projectile initiates on impact a nanoscale matrix environment that is very similar to that in frozen-hydrated samples in terms of the resulting ionisation effects. The competition between analytes for protons and the effect of the sample matrix are reduced with water-containing cluster projectiles. These chemically reactive projectile beams have improved characteristics for quantitative chemical imaging by TOF-SIMS compared with their non-reactive counterparts.
引用
收藏
页码:1962 / 1970
页数:9
相关论文
共 50 条
  • [1] Secondary ion mass spectrometry using polyatomic and cluster primary ion beams
    Gillen, G
    MICROBEAM ANALYSIS 2000, PROCEEDINGS, 2000, (165): : 339 - 340
  • [2] Ion yield improvement for static secondary ion mass spectrometry by use of polyatomic primary ions
    De Mondt, Roel
    Van Vaeck, Luc
    Heile, Andreas
    Arlinghaus, Heinrich F.
    Nieuwjaer, Nicolas
    Delcorte, Arnaud
    Bertrand, Patrick
    Lenaerts, Jens
    Vangaever, Frank
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (10) : 1481 - 1496
  • [3] Effectiveness of atomic and polyatomic primary ions for organic secondary ion mass spectrometry
    Diehnelt, CW
    Van Stipdonk, MJ
    Schweikert, EA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 207 (1-2) : 111 - 122
  • [4] SECONDARY ION MASS-SPECTROMETRY - POLYATOMIC AND MOLECULAR ION EMISSION
    COLTON, RJ
    ROSS, MM
    KIDWELL, DA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 13 (1-3): : 259 - 277
  • [5] MATRIX EFFECTS IN SECONDARY ION MASS-SPECTROMETRY
    BUSCH, KL
    HSU, BH
    XIE, YX
    COOKS, RG
    ANALYTICAL CHEMISTRY, 1983, 55 (07) : 1157 - 1160
  • [6] COMPARISON OF POLYATOMIC AND ATOMIC PRIMARY BEAMS FOR SECONDARY ION MASS-SPECTROMETRY OF ORGANICS
    APPELHANS, AD
    DELMORE, JE
    ANALYTICAL CHEMISTRY, 1989, 61 (10) : 1087 - 1093
  • [7] Comparison of primary monoatomic with primary polyatomic ions for the characterisation of polyesters with static secondary ion mass spectrometry
    Van Royen, P
    Taranu, A
    Van Vaeck, L
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (04) : 552 - 560
  • [8] Preliminary evaluation of an SF5+ polyatomic primary ion beam for analysis of organic thin films by secondary ion mass spectrometry
    Gillen, G
    Roberson, S
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (19) : 1303 - 1312
  • [10] The matrix effect in secondary ion mass spectrometry
    Seah, M. P.
    Shard, A. G.
    APPLIED SURFACE SCIENCE, 2018, 439 : 605 - 611