Joint Venting Prior to Hip Distraction Minimizes Traction Forces During Hip Arthroscopy

被引:7
|
作者
O'Neill, Dillon C. [1 ]
Mortensen, Alexander J. [2 ]
Tomasevich, Kelly M. [1 ]
Ohlsen, Suzanna M. [2 ]
Adeyemi, Temitope F. [1 ]
Maak, Travis G. [1 ]
Aoki, Stephen K. [1 ]
机构
[1] Univ Utah, Dept Orthopaed, Salt Lake City, UT USA
[2] Univ Utah, Sch Med, Salt Lake City, UT USA
关键词
ACETABULAR LABRAL TEAR; RECONSTRUCTION; COMPLICATIONS; STABILITY; RESECTION; SURGERY; REPAIR;
D O I
10.1016/j.arthro.2021.02.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: This study evaluates the effect of venting on distraction of the hip during arthroscopy on a post-free traction table for fixed traction forces ranging from 0 to 100 pounds (lbs). Methods: Patients underwent surgery by the senior author (S.K.A.) between November 2018 and July 2019. Inclusion criteria were primary hip arthroscopy requiring central compartment access. Patients were positioned in 10-15 degrees Trendelenburg on a post-free traction table. Prior to instrumentation, fluoroscopic images of the operated hip joint were taken at 25-lb intervals from 0 to 100 lbs of axial traction. Traction was released for 15 minutes. Venting with 20 mL of air was performed and fluoroscopic images were repeated at all traction intervals. Joint displacement was measured at all intervals. An unvented control group underwent the same axial traction protocol for comparison. Results: Sixty-one consecutive patients underwent study protocol. Fifty-eight hips in 57 patients were included. Thirty-two (55.2%) were female; mean age was 31 +/- 13 years and mean body mass index was 25.7 +/- 6.2. Paired samples analysis demonstrated mean differences in distraction distance prior to and after venting of 0.27, 2.60, 4.09, 4.54, and 2.31 mm at 0, 25, 50, 75, and 100 lbs of traction, which were significant (P < .001) at all traction intervals. Significantly more vented hips distracted at least 10 mm at 25-100 lbs traction (P < .001). An unvented control group showed no significant differences between the first and second traction application. Conclusions: Venting prior to applying traction on a post-free traction table increases the distraction distance achieved for a given traction force at multiple levels of traction in comparison to the pre-vented state. Our results suggest venting the hip joint prior to the application of traction may serve to reduce the maximal amount of traction required to safely instrument the hip arthroscopically. Level of Evidence: IV, case series.
引用
收藏
页码:2164 / 2170
页数:7
相关论文
共 50 条
  • [31] Postless Hip Arthroscopy: A Technical Note on Obtaining Distraction
    Leafblad, Nels
    Mizels, Josh
    Maak, Travis
    [J]. ARTHROSCOPY TECHNIQUES, 2024, 13 (01):
  • [32] Hip arthroscopy outcomes, complications, and traction safety in patients with prior lower-extremity arthroplasty
    Beutel, Bryan G.
    Collins, Jason A.
    Garofolo, Garret
    Youm, Thomas
    [J]. INTERNATIONAL ORTHOPAEDICS, 2015, 39 (01) : 13 - 18
  • [33] Hip arthroscopy outcomes, complications, and traction safety in patients with prior lower-extremity arthroplasty
    Bryan G. Beutel
    Jason A. Collins
    Garret Garofolo
    Thomas Youm
    [J]. International Orthopaedics, 2015, 39 : 13 - 18
  • [34] Hip Arthroscopy Neurapraxia: Is It Only About Weight of Traction?
    Birmingham, Patrick
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (22): : 2112 - 2112
  • [35] Traction-related problems after hip arthroscopy
    Frandsen, Lone
    Lund, Bent
    Nielsen, Torsten Gronbech
    Lind, Martin
    [J]. JOURNAL OF HIP PRESERVATION SURGERY, 2017, 4 (01): : 54 - 59
  • [36] Physiological Changes as a Result of Hip Arthroscopy Performed With Traction
    Martin, Hal D.
    Palmer, Ian J.
    Champlin, Keith
    Kaiser, Bill
    Kelly, Bryan
    Leunig, Michael
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (10): : 1365 - 1372
  • [37] Hip Distraction Without a Perineal Post A Prospective Study of 1000 Hip Arthroscopy Cases
    Mei-Dan, Omer
    Kraeutler, Matthew J.
    Garabekyan, Tigran
    Goodrich, Jesse A.
    Young, David A.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2018, 46 (03): : 632 - 641
  • [38] Distraction of the ankle joint during arthroscopy
    Ball, L.
    Hawken, R.
    Davis, J.
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2009, 91 (03) : 266 - 266
  • [39] Injections prior to hip arthroscopy are associated with increased risk of repeat hip arthroscopy at 1 and 5 years
    Andrea H. Johnson
    Jane C. Brennan
    Alyssa Maley
    Sandra B. Levermore
    Justin J. Turcotte
    Benjamin M. Petre
    [J]. Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 823 - 829
  • [40] Injections prior to hip arthroscopy are associated with increased risk of repeat hip arthroscopy at 1 and 5 years
    Johnson, Andrea H.
    Brennan, Jane C.
    Maley, Alyssa
    Levermore, Sandra B.
    Turcotte, Justin J.
    Petre, Benjamin M.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (02) : 823 - 829