Spatially resolved diffuse reflectance for the determination of tissue optical properties and metabolic state.

被引:5
|
作者
Forrester, KR [1 ]
Shymkiw, R [1 ]
Yeung, G [1 ]
Irwin, P [1 ]
Tulip, J [1 ]
Bray, R [1 ]
机构
[1] Univ Calgary, Calgary, AB T2N 4N1, Canada
关键词
diffuse reflectance spectroscopy; Monte Carlo; collagen; light guide; metabolic state;
D O I
10.1117/12.388060
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A multiple wavelength diffuse reflectance instrument was evaluated for the in-situ measurement of tissue optical properties. A diffusion dipole model with a non-linear least-squares fitting procedure was used to generate optical properties from the radial profiles of diffuse reflectance measurements. The diffusion model was compared with Monte Carlo simulations showing acceptable agreement for a range of distances far enough away from the source point. Instrumentation was evaluated by experimental measurement of tissue simulating phantoms where measured optical properties were compared to those obtained using a collimated transmission setup. The results showed agreement to within 5-10%. The optical properties of rabbit ligament and tendon are reported where anisotropic scattering due to collagen alignment was observed. This study represents the first known measurement of rabbit ligament and tendon optical properties and the use of diffuse reflectance to measure the "lightguide" effects of collagen alignment. To evaluate instrument response to changes in tissue oxygenation levels the optical properties of human skin were measured before and during arterial occlusion. During arterial occlusion absorption at 633 nm increased while absorption at 810 nm remained relatively constant. These results are consistent with the deoxygenation of hemoglobin that occurs during occlusion.
引用
收藏
页码:333 / 344
页数:12
相关论文
共 50 条
  • [31] Improved algorithm for estimating the optical properties of food products using spatially-resolved diffuse reflectance
    Wang, Aichen
    Lu, Renfu
    Xie, Lijuan
    JOURNAL OF FOOD ENGINEERING, 2017, 212 : 1 - 11
  • [32] Optical properties of phantoms and tissue measured in vivo from 0.9-1.3 mu m using spatially resolved diffuse reflectance
    Bruulsema, JT
    Hayward, JE
    Farrell, TJ
    Essenpreis, M
    Patterson, MS
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF, 1997, 2979 : 325 - 334
  • [33] Tissue optical properties from spatially resolved reflectance: calibration and in vivo application on rat kidney
    Gladytz, Thomas
    Hoppe, Alexander
    Cantow, Kathleen
    Flemming, Bert
    Pohlmann, Andreas
    Niendorf, Thoralf
    Seeliger, Erdmann
    Grosenick, Dirk
    DIFFUSE OPTICAL SPECTROSCOPY AND IMAGING VI, 2017, 10412
  • [34] Multivariate method for the determination of tissue optical properties from diffuse reflectance profiles
    Yeh, SJ
    Khalil, OS
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE III, PROCEEDINGS OF, 1999, 3597 : 456 - 464
  • [35] Study on the Determination System of Tissue Optical Properties Based on Diffuse Reflectance Spectrum
    Li Chen-xi
    Sun Zhe
    Han Lei
    Zhao Hui-juan
    Xu Ke-xin
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (05) : 1532 - 1536
  • [36] Determination of tissue optical properties from diffuse reflectance profiles by multivariate calibration
    Dam, JS
    Andersen, PE
    Dalgaard, T
    Fabricius, PE
    APPLIED OPTICS, 1998, 37 (04): : 772 - 778
  • [37] Optimization of inverse algorithm for estimating the optical properties of biological materials using spatially-resolved diffuse reflectance
    Cen, Haiyan
    Lu, Renfu
    Dolan, Kirk
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2010, 18 (06) : 853 - 872
  • [38] Metamodeling approach for efficient estimation of optical properties of turbid media from spatially resolved diffuse reflectance measurements
    Watte, Rodrigo
    Nghia Nguyen Do Trong
    Aernouts, Ben
    Erkinbaev, Chyngyz
    De Baerdemaeker, Josse
    Nicolai, Bart
    Saeys, Wouter
    OPTICS EXPRESS, 2013, 21 (26): : 32630 - 32642
  • [39] In vivo determination of local skin optical properties and photon path length by use of spatially resolved diffuse reflectance with applications in laser Doppler flowmetry
    Larsson, M
    Nilsson, H
    Strömberg, T
    APPLIED OPTICS, 2003, 42 (01) : 124 - 134
  • [40] Influence of layered tissue architecture on estimates of tissue optical properties obtained from spatially resolved diffuse reflectometry
    Farrell, TJ
    Patterson, MS
    Essenpreis, M
    APPLIED OPTICS, 1998, 37 (10): : 1958 - 1972