Experimental investigation on the thermal performance of vapor chamber in a compound liquid cooling system

被引:28
|
作者
Li, Weiping [1 ,2 ]
Li, Longjian [1 ,2 ]
Cui, Wenzhi [1 ,2 ]
Guo, Mengting [1 ,2 ]
机构
[1] Chongqing Univ, Sch Energy & Power Engn, Chongqing 400030, Peoples R China
[2] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ PRC, Chongqing 400030, Peoples R China
关键词
Compound liquid cooling system; Vapor chamber; Temperature uniformity; Thermal resistance; Battery thermal management; LITHIUM-ION BATTERY; PLATE HEAT-PIPE; MANAGEMENT-SYSTEM; FLOW CONFIGURATION; OPTIMIZATION; RESISTANCE; COLUMNS; DESIGN; WICK;
D O I
10.1016/j.ijheatmasstransfer.2021.121026
中图分类号
O414.1 [热力学];
学科分类号
摘要
To develop an efficient and practicable liquid cooling system for battery thermal management, a compound liquid cooling system combining a grooved aluminum vapor chamber with a one-through flow cold plate was proposed and its thermal performance experimentally was studied. The heating power, coolant flow rate, filling ratio and tilting angle of the vapor chamber were investigated, which had an impact on the thermal resistance and temperature difference on the heating surface. The results showed that the vapor chamber with a 20%similar to 30% filling ratio had the smallest thermal resistance and preferable temperature uniformity in horizontal configuration. Due to the heat and mass transport of phases along the longitudinal direction inside the vapor chamber, the temperature difference of the heating surface arising from the temperature rise of the coolant could be suppressed effectively. To evaluate the suppressed effect on the temperature difference of the heating surface, the suppression ratio was proposed. The suppression ratio on the heating surface rose with the increase in heating power and the decrease in flowing rate. The thermal resistance and temperature uniformity of the vapor chamber deteriorated in tilting configuration. The vapor chamber at a positive tilting angle configuration performed better compared with that at a negative tilting angle configuration. At 20%similar to 30% filling ratio, the suppression ratio of the temperature difference on the heating surface could be achieved at 0.78 under positive tilting angle configuration. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Experimental investigation on thermal performance of aluminum vapor chamber using micro-grooved wick with reentrant cavity array
    Zeng, Jian
    Zhang, Shiwei
    Chen, Gong
    Lin, Lang
    Sun, Yalong
    Chuai, Lin
    Yuan, Wei
    APPLIED THERMAL ENGINEERING, 2018, 130 : 185 - 194
  • [42] Thermal performance of a pin-finned vapor chamber heat spreader for CPU cooling applications
    Maalej, Samah
    Saad, Imene
    Mansouri, Jed
    Sedki, Iheb
    Zaghdoudi, Mohamed Chaker
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (05)
  • [43] EXPERIMENTAL INVESTIGATION OF THERMAL-CONDUCTIVITY OF HYDROCARBONS IN LIQUID AND VAPOR PHASES
    MUSTAFAEV, RA
    HIGH TEMPERATURE, 1974, 12 (04) : 772 - 775
  • [44] Thermal performance of a pin-finned vapor chamber heat spreader for CPU cooling applications
    Samah Maalej
    Imène Saad
    Jed Mansouri
    Iheb Sedki
    Mohamed Chaker Zaghdoudi
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2024, 46
  • [45] Experimental investigation of cooling performance of milk cooling tank with the vapor compressed and solar absorption (LiCl-H2O) cooling system
    Süt soǧutma tankinin buhar sikiştirmali ve güneş enerjili absorpsiyonlu
    1600, Gazi Universitesi (31):
  • [46] Experimental investigation of the performance of an air type photovoltaic thermal collector system with fixed cooling fins
    Zhao, Zhonghua
    Zhu, Li
    Wang, Yiping
    Huang, Qunwu
    Sun, Yong
    ENERGY REPORTS, 2023, 9 : 93 - 100
  • [47] Experimental Investigation on Thermal Performance of a PV/T-PCM (Photovoltaic/Thermal) System Cooling with a PCM and Nanofluid
    Sarafraz, M. M.
    Safaei, Mohammad Reza
    Leon, Arturo S.
    Tlili, Iskander
    Alkanhal, Tawfeeq Abdullah
    Tian, Zhe
    Goodarzi, Marjan
    Arjomandi, M.
    ENERGIES, 2019, 12 (13)
  • [48] Experimental research on battery thermal management system based on vapor chamber technology
    Dan D.
    Lian H.
    Zhang Y.
    Yao C.
    Wang Y.
    Ren W.
    Zhuge W.
    Qian Y.
    Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2019, 49 (09): : 1023 - 1030
  • [49] On the thermal cooling of central processing unit of the PCs with vapor chamber
    Naphon, Paisarn
    Wongwises, Somchai
    Wiriyasart, Songkran
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2012, 39 (08) : 1165 - 1168
  • [50] Thermal performance evaluation of thin vapor chamber
    Chang, S. W.
    Chiang, K. F.
    Cai, W. L.
    APPLIED THERMAL ENGINEERING, 2019, 149 : 220 - 230