CARBON NANOTUBES-GRAPHITE PASTE ELECTRODE MODIFIED WITH Cu(II)-EXCHANGED ZEOLITE FOR H2O2 DETECTION

被引:0
|
作者
Gligor, Delia [1 ]
Varodi, Codruta [2 ]
Maicaneanu, Andrada [3 ]
Muresan, Liana Maria [3 ]
机构
[1] Univ Babes Bolyai, Fac Stiinta Mediului, RO-400084 Cluj Napoca, Romania
[2] Inst Natl Cercetare Dezvoltare Pentru Tehnol Izot, RO-400293 Cluj Napoca, Romania
[3] Univ Babes Bolyai, Fac Chim Ingn Chim, RO-400084 Cluj Napoca, Romania
来源
关键词
carbon paste electrodes; zeolite; hydrogen peroxide; carbon nanotubes; HYDROGEN-PEROXIDE; ENZYME; SENSOR;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Modification of a natural zeolite from Macicas (Cluj County, Romania) with copper(II) (Z-Cu), followed by its incorporation in carbon paste, made of carbon nanotubes and graphite powder as conductive matrix (Z-Cu-G-CNT- CPEs), lead to a stable modified electrode. The Z-Cu-G-CNT-CPEs electrodes show significant electrocatalytic activity toward H2O2 reduction. The rate constant for catalytic H2O2 reduction, estimated from rotating disk electrode measurements, extrapolated to zero H2O2 concentration was found to be 74.4 M-1 s(-1) (pH 7). The amperometric detection of H2O2, at -400 mV vs. Ag/AgCl/KClsat is characterized by the following electroanalytical parameters: sensitivity of 15.33 mA M-1, detection limit of 0.24 mM and linear domain up to 10 mM H2O2.
引用
收藏
页码:293 / 302
页数:10
相关论文
共 50 条
  • [21] Effect of Buffer Solution on the Detection of Cu(II) by Graphite Carbon Nitride Modified Electrode
    Huiqin Xianhua Li
    Kuan Li
    Qingping Yang
    Qingbo Wang
    Russian Journal of Electrochemistry, 2022, 58 : 444 - 450
  • [22] Effect of Buffer Solution on the Detection of Cu(II) by Graphite Carbon Nitride Modified Electrode
    Li, Xianhua
    Li, Huiqin
    Yang, Kuan
    Wang, Qingping
    Yu, Qingbo
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2022, 58 (06) : 444 - 450
  • [23] Preparation and Assessment of a Polysafranin/Multiwall Carbon Nanotube-Nafion Hybrid Film–Modified Carbon Paste Electrode and Its Performance as an Easy Sensing Probe for H2O2 and Cu2+
    M. Sayahpour
    S. Hashemnia
    Z. Mokhtari
    Electrocatalysis, 2021, 12 : 91 - 100
  • [24] Anthraquinone Covalently Modified Carbon Nanotubes for Efficient and Steady Electrocatalytic H2O2 Generation
    Fangyuan Yu
    Kai Wang
    Chuan Wang
    Xinxia He
    Yang Liao
    Shilin Zhao
    Hui Mao
    Xiaoting Li
    Jun Ma
    Chemical Research in Chinese Universities, 2020, 36 : 1332 - 1338
  • [25] Cu(II) hexacyanoferrate (III) modified carbon paste electrode; Application for electrocatalytic detection of nitrite
    Ojani, Reza
    Raoof, Jahan-Bakhsh
    Norouzi, Banafsheh
    ELECTROANALYSIS, 2008, 20 (18) : 1996 - 2002
  • [26] Cu-Pt-Bi Nanocomposite Modified Glassy Carbon Electrode for Dual Mode H2O2 and Cholesterol Sensing
    Soorya, V. C.
    Berchmans, Sheela
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (09) : B435 - B442
  • [27] Fabrication of Gold Nanoparticles Modified Carbon Nanofibers/Polyaniline Electrode for H2O2 Determination
    Bao, Shiyong
    Du, Mingliang
    Zhang, Ming
    Zhu, Han
    Wang, Pan
    Yang, Tingting
    Zou, Meiling
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (12) : H816 - H821
  • [28] Vitreous carbon electrode modified with complexing Fe(III) alizarin for H2O2 reduction
    Oniciu, L
    Corabian, C
    Muresan, L
    REVISTA DE CHIMIE, 1997, 48 (10-11): : 901 - 904
  • [29] A zeolite modified carbon paste electrode based on copper exchanged clinoptilolite nanoparticles for voltammetric determination of metronidazole
    Shahnazari-Shahrezaie, Elahe
    Nezamzadeh-Ejhieh, Alireza
    RSC ADVANCES, 2017, 7 (23): : 14247 - 14253
  • [30] Electrocatalytic measurement of H2O2 concentration using bis(N-2-methylphenyl-salicyldenaminato)copper(II) spiked in a carbon paste electrode
    Khoshro, Hossein
    Zare, Hamid R.
    Vafazadeh, Rasoul
    CHINESE JOURNAL OF CATALYSIS, 2014, 35 (02) : 247 - 254