Zero-Heat-Flux Thermometry for Non-Invasive Measurement of Core Body Temperature in Pigs

被引:15
|
作者
Guschlbauer, Maria [1 ]
Maul, Alexandra C. [1 ]
Yan, Xiaowei [2 ]
Herff, Holger [2 ]
Annecke, Thorsten [2 ]
Sterner-Kock, Anja [1 ]
Boettiger, Bernd W. [2 ]
Schroeder, Daniel C.
机构
[1] Univ Hosp Cologne, Ctr Med Expt, Cologne, Germany
[2] Univ Hosp Cologne, Dept Anaesthesiol & Intens Care Med, Cologne, Germany
来源
PLOS ONE | 2016年 / 11卷 / 03期
关键词
MILD PERIOPERATIVE HYPOTHERMIA; THERAPEUTIC HYPOTHERMIA; HEMORRHAGIC-SHOCK; WOUND-INFECTION; CARDIAC-ARREST; BLOOD-LOSS; ANESTHESIA; SWINE; MODEL; NORMOTHERMIA;
D O I
10.1371/journal.pone.0150759
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Hypothermia is a severe, unpleasant side effect during general anesthesia. Thus, temperature surveillance is a prerequisite in general anesthesia settings during experimental surgeries. The gold standard to measure the core body temperature (T-core) is placement of a Swan-Ganz catheter in the pulmonary artery, which is a highly invasive procedure. Therefore, T-core is commonly examined in the urine bladder and rectum. However, these procedures are known for their inaccuracy and delayed record of temperatures. Zero-heat-flux (ZHF) thermometry is an alternative, non-invasive method quantifying T-core in human patients by applying a thermosensoric patch to the lateral forehead. Since the porcine cranial anatomy is different to the human's, the optimal location of the patch remains unclear to date. The aim was to compare three different patch locations of ZHF thermometry in a porcine hypothermia model. Hypothermia (33.0 degrees C T-core) was conducted in 11 anesthetized female pigs (26-30kg). T-core was measured continuously by an invasive Swan-Ganz catheter in the pulmonary artery (T-pulm). A ZHF thermometry device was mounted on three different defined locations. The smallest average difference between T-pulm and T-ZHF during stable temperatures was 0.21 +/- 0.16 degrees C at location A, where the patch was placed directly behind the eye. Also during rapidly changing temperatures location A showed the smallest bias with 0.48 +/- 0.29 degrees C. Location A provided the most reliable data for T-core. Therefore, the ZHF thermometry patch should be placed directly behind the left temporal corner of the eye to provide a non-invasive method for accurate measurement of T-core in pigs.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Accuracy of Zero-Heat-Flux Cutaneous Temperature in Intensive Care Adults
    Dahyot-Fizelier, Claire
    Lamarche, Solene
    Kerforne, Thomas
    Benard, Thierry
    Giraud, Benoit
    Bellier, Remy
    Carise, Elsa
    Frasca, Denis
    Mimoz, Olivier
    CRITICAL CARE MEDICINE, 2017, 45 (07) : E715 - E717
  • [32] Intraoperative zero-heat-flux thermometry overestimates esophageal temperature by 0.26 °C: an observational study in 100 infants and young children
    Marcus Nemeth
    Marijana Lovric
    Thomas Asendorf
    Anselm Bräuer
    Clemens Miller
    Journal of Clinical Monitoring and Computing, 2021, 35 : 1445 - 1451
  • [33] Intraoperative zero-heat-flux thermometry overestimates esophageal temperature by 0.26 °C: an observational study in 100 infants and young children
    Nemeth, Marcus
    Lovric, Marijana
    Asendorf, Thomas
    Brauer, Anselm
    Miller, Clemens
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (06) : 1445 - 1451
  • [34] Validation of the Zero-Heat-Flux thermometer (SpotOn®) in major gynecological surgery to monitor intraoperative core temperature: a comparative study with esophageal core temperature
    Kollmann Camaiora, Andrea
    Brogly, Nicolas
    Alsina, Estibaliz
    de Celis, Isabel
    Huercio, Ivan
    Gilsanz, Fernando
    MINERVA ANESTESIOLOGICA, 2019, 85 (04) : 351 - 357
  • [35] Zero-Heat-Flux and Esophageal Temperature Monitoring in Orthopedic Surgery: An Observational Study
    Munday, Judy
    Higgins, Niall
    Jones, Lee
    Vagenas, Dimitrios
    Van Zundert, Andre
    Keogh, Samantha
    JOURNAL OF MULTIDISCIPLINARY HEALTHCARE, 2021, 14 : 1819 - 1827
  • [36] Non-invasive Core Body Temperature Sensor for Continuous Monitoring
    Anuar, Hamizah
    Leow, Pei Ling
    2019 IEEE INTERNATIONAL CONFERENCE ON SENSORS AND NANOTECHNOLOGY (SN), 2019, : 61 - 64
  • [37] Intraoperative zero-heat-flux thermometry overestimates nasopharyngeal temperature by 0.39 °C: an observational study in patients undergoing congenital heart surgery
    Brandes, Ivo F.
    Tirilomis, Theodor
    Nemeth, Marcus
    Wieditz, Johannes
    Braeuer, Anselm
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, : 205 - 215
  • [38] Sustained exercise load by young adult females while wearing surgical mask raises core body temperature measured with zero-heat-flux thermometer
    Ayako Fukushima
    Yoshie Manabe
    Yuri Kosaka
    Shuji Akagi
    International Journal of Biometeorology, 2023, 67 : 1345 - 1352
  • [39] Clinical accuracy of infrared temperature measurement devices: a comparison against non-invasive core-body temperature
    Holder, Thomas
    Hooper, Frances Sophie Woodley
    Yates, David
    Tse, Zion
    Patil, Samadhan
    Moussa, Ahmed
    Batten, Lucy
    Radhakrishnan, Vignesh
    Allison, Mark
    Hewitt, Catherine
    Keding, Ada
    Forshaw, Greg
    Jayagopal, Vijay
    CLINICAL MEDICINE, 2023, 23 (02) : 157 - 163
  • [40] Confounding factors in the use of the zero-heat-flow method for non-invasive muscle temperature measurement
    Brajkovic, D
    Ducharme, M
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2005, 94 (04) : 386 - 391