Influence of different design parameters on the seismic performance of partially grouted masonry shear walls

被引:20
|
作者
Calderon, Sebastian [1 ,2 ]
Sandoval, Cristian [1 ,3 ]
Araya-Letelier, Gerardo [4 ]
Inzunza, Ernesto [1 ]
Arnau, Oriol [5 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Casilla 306,Correo 22, Santiago, Chile
[2] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[3] Pontificia Univ Catolica Chile, Sch Architecture, Casilla 306,Correo 22, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Sch Civil Construct, Casilla 306,Correo 22, Santiago, Chile
[5] Iktes, Mexico City, DF, Mexico
关键词
Reinforced masonry; Partially-grouted masonry; In-plane testing; Shear response; Shear walls; BEHAVIOR;
D O I
10.1016/j.engstruct.2021.112058
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent earthquakes in Chile (e.g., Maule's 2010 earthquake), buildings built with bed-joint partially grouted reinforced masonry (BJ-PG-RM) shear walls made of multi-perforated clay bricks (MPCB) have not collapsed, although significant damages have been reported. Additionally, experimental data on the influence of the different design parameters that control its seismic behavior is scarce, and the available expressions for estimating their lateral resistance are inaccurate. To address these issues, nine full-scale BJ-PG-RM walls made of MPCB were tested under axial pre-compression and cyclic lateral loads. The study addressed the influence of the aspect (height-to-length) ratio, axial pre-compression, mortar compressive strength, mortar joints' thickness, bricks' height, and horizontal and vertical reinforcement ratio. The results were analyzed in terms of hysteretic response, damage evolution, seismic performance parameters (shear strength, equivalent viscous damping ratio, ductility, and lateral stiffness degradation). All designed walls failed in a diagonal tension failure mode. Besides, all studied variables influenced the stresses and crack patterns. Also, the shear strength increases when: (i) lower aspect ratio or joint thickness are used; and (ii) higher axial load ratio, horizontal reinforcement ratio, vertical reinforcement ratio, or mortar compressive strength are used. Moreover, when damage progresses, the lateral secant stiffness decays faster as a result of: (i) larger joint thickness or vertical reinforcement ratio; (ii) lower mortar compressive strength. Most walls exhibited an equivalent viscous damping ratio between 5% and 10% for an intermediate state of damage. However, the evaluated design parameters did not considerably affect the development of the viscous damping ratio as a function of the drift ratio. The displacement ductility of the walls ranged from 1.5 to 2.5, where the height of bricks and the vertical reinforcement ratio had positive effects, and the joint thickness, the mortar compressive strength, and the horizontal reinforcement ratio a negative effect. The lateral resistance of tested walls was also estimated with six expressions, but none of them provided accurate results.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] Performance of partially grouted reinforced masonry walls with bed-joint reinforcement: parametric and optimization investigation
    Faridmehr, Iman
    Nehdi, Moncef L.
    Farokhi Nejad, Ali
    Valerievich, Kiyanets Aleksandr
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2023, 24 (01)
  • [42] Performance of partially grouted reinforced masonry walls with bed-joint reinforcement: parametric and optimization investigation
    Iman Faridmehr
    Moncef L. Nehdi
    Ali Farokhi Nejad
    Kiyanets Aleksandr Valerievich
    Archives of Civil and Mechanical Engineering, 24
  • [43] Numerical assessment of TMS 402/602-22 and CSA S304-14 seismic design provisions for partially grouted reinforced masonry shear walls failing in flexure
    Elmeligy, Omar
    Abdelrahman, Belal
    Galal, Khaled
    ENGINEERING STRUCTURES, 2024, 303
  • [44] In-plane shear strength equation for fully grouted reinforced masonry shear walls
    ElDin, Hany M. Seif
    Aly, Nader
    Galal, Khaled
    ENGINEERING STRUCTURES, 2019, 190 : 319 - 332
  • [45] Seismic Performance Investigation of different kinds of Shear Walls
    Zhang, Pinle
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 1615 - 1618
  • [46] DESIGN AND PERFORMANCE PARAMETERS OF SHEAR WALLS: A REVIEW
    Aydin, Abdulkadir Cuneyt
    Bayrak, Baris
    ARCHITECTURE CIVIL ENGINEERING ENVIRONMENT, 2021, 14 (04) : 69 - 93
  • [47] Study of the influence of different parameters on the buckling behaviour of masonry walls
    Sandoval, Cristian
    Roca, Pere
    CONSTRUCTION AND BUILDING MATERIALS, 2012, 35 : 888 - 899
  • [48] Seismic performance of low aspect ratio reinforced block masonry shear walls
    Larbi, A.
    Harris, H.G.
    Proceedings of the US National Conference on Earthquake Engineering, 1990,
  • [49] Experimental and Numerical Study on the Seismic Performance of Prefabricated Reinforced Masonry Shear Walls
    Xu, Weifan
    Yang, Xu
    Wang, Fenglai
    Chi, Bin
    APPLIED SCIENCES-BASEL, 2018, 8 (10):
  • [50] Shear response of partially-grouted reinforced masonry walls with a central opening: Testing and detailed micro-modelling
    Calderon, Sebastian
    Sandoval, Cristian
    Arnau, Oriol
    MATERIALS & DESIGN, 2017, 118 : 122 - 137