Influence of different design parameters on the seismic performance of partially grouted masonry shear walls

被引:20
|
作者
Calderon, Sebastian [1 ,2 ]
Sandoval, Cristian [1 ,3 ]
Araya-Letelier, Gerardo [4 ]
Inzunza, Ernesto [1 ]
Arnau, Oriol [5 ]
机构
[1] Pontificia Univ Catolica Chile, Dept Struct & Geotech Engn, Casilla 306,Correo 22, Santiago, Chile
[2] Politecn Milan, Dept Architecture Built Environm & Construct Engn, Piazza Leonardo da Vinci 32, I-20133 Milan, Italy
[3] Pontificia Univ Catolica Chile, Sch Architecture, Casilla 306,Correo 22, Santiago, Chile
[4] Pontificia Univ Catolica Chile, Sch Civil Construct, Casilla 306,Correo 22, Santiago, Chile
[5] Iktes, Mexico City, DF, Mexico
关键词
Reinforced masonry; Partially-grouted masonry; In-plane testing; Shear response; Shear walls; BEHAVIOR;
D O I
10.1016/j.engstruct.2021.112058
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent earthquakes in Chile (e.g., Maule's 2010 earthquake), buildings built with bed-joint partially grouted reinforced masonry (BJ-PG-RM) shear walls made of multi-perforated clay bricks (MPCB) have not collapsed, although significant damages have been reported. Additionally, experimental data on the influence of the different design parameters that control its seismic behavior is scarce, and the available expressions for estimating their lateral resistance are inaccurate. To address these issues, nine full-scale BJ-PG-RM walls made of MPCB were tested under axial pre-compression and cyclic lateral loads. The study addressed the influence of the aspect (height-to-length) ratio, axial pre-compression, mortar compressive strength, mortar joints' thickness, bricks' height, and horizontal and vertical reinforcement ratio. The results were analyzed in terms of hysteretic response, damage evolution, seismic performance parameters (shear strength, equivalent viscous damping ratio, ductility, and lateral stiffness degradation). All designed walls failed in a diagonal tension failure mode. Besides, all studied variables influenced the stresses and crack patterns. Also, the shear strength increases when: (i) lower aspect ratio or joint thickness are used; and (ii) higher axial load ratio, horizontal reinforcement ratio, vertical reinforcement ratio, or mortar compressive strength are used. Moreover, when damage progresses, the lateral secant stiffness decays faster as a result of: (i) larger joint thickness or vertical reinforcement ratio; (ii) lower mortar compressive strength. Most walls exhibited an equivalent viscous damping ratio between 5% and 10% for an intermediate state of damage. However, the evaluated design parameters did not considerably affect the development of the viscous damping ratio as a function of the drift ratio. The displacement ductility of the walls ranged from 1.5 to 2.5, where the height of bricks and the vertical reinforcement ratio had positive effects, and the joint thickness, the mortar compressive strength, and the horizontal reinforcement ratio a negative effect. The lateral resistance of tested walls was also estimated with six expressions, but none of them provided accurate results.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Seismic resistance of partially-grouted masonry shear walls
    Schultz, AE
    WORLDWIDE ADVANCES IN STRUCTURAL CONCRETE AND MASONRY, 1996, : 211 - 222
  • [2] Seismic performance parameters of fully grouted reinforced masonry squat shear walls
    EDin, Hany M. Seif
    Ashour, Ahmed
    Galal, Khaled
    ENGINEERING STRUCTURES, 2019, 187 : 518 - 527
  • [3] Shear strength expression for partially grouted masonry walls
    Bolhassani, M.
    Hamid, A. A.
    Johnson, C.
    Schultz, A. E.
    ENGINEERING STRUCTURES, 2016, 127 : 475 - 494
  • [4] Seismic behavior of partially grouted masonry shear walls containing openings: Experimental testing
    Vargas, Laura
    Bertolesi, Elisa
    Sandoval, Cristian
    Calderon, Sebastian
    ENGINEERING STRUCTURES, 2023, 278
  • [5] In-Plane Seismic Performance of Fully Grouted Reinforced Masonry Shear Walls
    Eldin, Hany M. Seif
    Galal, Khaled
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (07)
  • [6] Shear design equation and updated fragility functions for partially grouted reinforced masonry shear walls
    Calderon, Sebastian
    Vargas, Laura
    Sandoval, Cristian
    Araya-Letelier, Gerardo
    Milani, Gabriele
    JOURNAL OF BUILDING ENGINEERING, 2022, 50
  • [7] Static Cyclic Response of Partially Grouted Masonry Shear Walls
    Nolph, Shawn M.
    ElGawady, Mohamed A.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2012, 138 (07): : 864 - 879
  • [8] Influence of a window-type opening on the shear response of partially-grouted masonry shear walls
    Calderon, Sebastian
    Sandoval, Cristian
    Inzunza, Ernesto
    Cruz-Noguez, Carlos
    Rahim, Amr Ba
    Vargas, Laura
    ENGINEERING STRUCTURES, 2019, 201
  • [9] Effect of Spacing of Reinforcement on the Behaviour of Partially Grouted Masonry Shear Walls
    Dhanasekar, Manicka
    Haider, Waheed
    ADVANCES IN STRUCTURAL ENGINEERING, 2011, 14 (02) : 281 - 293
  • [10] Simplified analytical models for partially grouted reinforced masonry shear walls
    Al-Ahdal, Abdulelah
    Aly, Nader
    Galal, Khaled
    ENGINEERING STRUCTURES, 2022, 252