Skull Base Meningioma - Comparison of Intensity-modulated Radiotherapy Planning Techniques using the Moduleaf Micro-multileaf Collimator and Helical Tomotherapy

被引:9
|
作者
Estall, V. [1 ]
Fairfoul, J. [2 ]
Jena, R.
Jefferies, S. J.
Burton, K. E.
Burnet, N. G. [3 ]
机构
[1] PeterMac Canc Ctr, Melbourne, Vic 3002, Australia
[2] Addenbrookes Hosp, Dept Med Phys, Cambridge, England
[3] Univ Cambridge, Addenbrookes Hosp, Dept Oncol, Ctr Oncol, Cambridge CB2 2QQ, England
关键词
IMRT; meningioma; tomotherapy; skull base; FRACTIONATED STEREOTACTIC RADIOTHERAPY; EXTERNAL-BEAM IRRADIATION; TIME-DOSE FACTORS; CONFORMAL RADIOTHERAPY; MALIGNANT MENINGIOMAS; RADIATION-THERAPY; TUMORS; TOLERANCE; DAMAGE;
D O I
10.1016/j.clon.2010.01.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aims: Therapeutic radiotherapy to lesions of the skull base is limited by complex target shapes and their proximity to organs at Fisk. Intensity-modulated radiotherapy (mu) using helical tomotherapy may result in improved dose distributions and safer close escalation. The aim of this study was to compare plan efficacy and efficiency using, linac-based micro-multileaf collimator (mMLC) IMRT and helical tomotherapy. Materials and methods: Five cases of skull base meningioma, previously treated with three-dimensional conformal radiotherapy (50 Gy/30 fractions) were identified. They were re-planned to a dose of 60 Gy/30 fractions using IMRT with Moduleaf mMLC (2.5 mm) and helical tomotherapy. Plan efficacy was compared using measures of PTV60 coverage (D-min, D-max, V-90%, V-95% and V-100%). Plan efficiency was assessed by comparing estimated beam-on times. Results: The critical structure dose was limited to below predetermined tolerance levels in all cases, with similar closes obtained between techniques. The average PTV60 D-max, D-min, D-med, D-mean, V-90%, V-95% and V-100% across the five cases achieved were as follows: mMLC IMRT: 64.9 Gy, 40.1 Gy, 60 Gy, 59.6 Gy, 95.4%, 88.8% and 69.2%, respectively; helical tomotherapy: 67.2 Gy, 50.3 Gy, 60 Gy, 59.9 Gy, 95.8%, 83.5% and 51.9%, respectively. The average treatment time per fraction was 18.4 min for IMRT with mMLC and 6.7 min for helical tomotherapy. Discussion: This study shows that safe dose escalation to a dose of 60 G y to skull base lesions can be achieved: using either mMLC- or helical tomotherapy-based IMRT. A plan comparison between the two solutions is difficult, but they seem to be similar in efficacy with any small differences being difficult to interpret and of questionable clinical significance. Helical tomotherapy has the advantage of a significantly decreased beam-on time. (C) 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 50 条
  • [31] Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostate
    Burman, C
    Chui, CS
    Kutcher, G
    Leibel, S
    Zelefsky, M
    LoSasso, T
    Spirou, S
    Wu, QW
    Yang, J
    Stein, J
    Mohan, R
    Fuks, Z
    Ling, CC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (04): : 863 - 873
  • [32] Intensity-modulated radiotherapy, volume-modulated arc therapy and helical tomotherapy for locally advanced nasopharyngeal carcinoma: a dosimetric comparison
    Chen, Wen
    Yang, Xiaoyu
    Jiang, Nian
    Zhang, Zijian
    Hong, Jidong
    He, Yuxiang
    Luo, Junli
    Liang, Ying
    Wei, Rui
    TRANSLATIONAL CANCER RESEARCH, 2017, 6 (05) : 929 - 939
  • [33] Dosimetric comparison of helical TomoTherapy treatment and step-and-shoot intensity-modulated radiotherapy treatment on retroperitoneal sarcoma
    Liu, A
    Pezner, RD
    Han, C
    Schultheiss, TE
    Wong, JY
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S454 - S454
  • [34] A dosimetric comparison between two intensity-modulated radiotherapy techniques:: tomotherapy vs dynamic linear accelerator
    Whitelaw, G. L.
    Blasiak-Wal, I.
    Cooke, K.
    Usher, C.
    Macdougall, N. D.
    Plowman, P. N.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (964): : 333 - 340
  • [35] Dosimetric effect of multileaf collimator leaf width in intensity-modulated radiotherapy delivery techniques for small- and large-volume targets
    Yoganathan, S. A.
    Mani, Karthick Raj
    Das, K. J. Maria
    Agarwal, Arpita
    Kumar, Shaleen
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (02) : 72 - 77
  • [36] Intensity-modulated radiotherapy for complex-shaped meningioma of the skull base: Long-term experience of a single institution
    Milker-Zabel, Stefanie
    Bois, Angelika Zabel-Du
    Huber, Peter
    Schlegel, Wolfgang
    Debus, Juergen
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03): : 858 - 863
  • [37] Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer
    Youling Gong
    Shichao Wang
    Lin Zhou
    Yongmei Liu
    Yong Xu
    You Lu
    Sen Bai
    Yuchuan Fu
    Qingfeng Xu
    Qingfeng Jiang
    Radiation Oncology, 5
  • [38] Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer
    Gong, Youling
    Wang, Shichao
    Zhou, Lin
    Liu, Yongmei
    Xu, Yong
    Lu, You
    Bai, Sen
    Fu, Yuchuan
    Xu, Qingfeng
    Jiang, Qingfeng
    RADIATION ONCOLOGY, 2010, 5
  • [39] Hemithoracic Intensity-modulated Radiotherapy Using Helical Tomotherapy for Patients after Extrapleural Pneumonectomy for Malignant Pleural Mesothelioma
    Ebara, Takeshi
    Kawamura, Hidemasa
    Kaminuma, Takuya
    Okamoto, Masahiko
    Yoshida, Daisaku
    Okubo, Yu
    Takahashi, Takeo
    Kobayashi, Kunihiko
    Sakaguchi, Hirozo
    Ando, Yoshitaka
    Nakano, Takashi
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (02) : 288 - 294
  • [40] Safety and Efficacy of Intensity-Modulated Stereotactic Body Radiotherapy Using Helical Tomotherapy for Lung Cancer and Lung Metastasis
    Nagai, Aiko
    Shibamoto, Yuta
    Yoshida, Masanori
    Inoda, Koji
    Kikuchi, Yuzo
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014