Long-term Assessment of Tilt of Glued Intraocular Lenses An Optical Coherence Tomography Analysis 5 Years after Surgery

被引:32
|
作者
Kumar, Dhivya Ashok [1 ]
Agarwal, Amar [1 ]
Agarwal, Athiya [1 ]
Chandrasekar, Radika [1 ]
Priyanka, Vijetha [1 ]
机构
[1] Dr Agarwals Eye Hosp & Eye Res Ctr, Madras 600086, Tamil Nadu, India
关键词
ULTRASOUND BIOMICROSCOPY; INTRASCLERAL FIXATION; ASTIGMATISM ANALYSIS; CAPSULAR SUPPORT; CATARACT-SURGERY; ANTERIOR-CHAMBER; VISUAL OUTCOMES; FIBRIN SEALANT; IMPLANTATION; EYES;
D O I
10.1016/j.ophtha.2014.07.032
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Long-term assessment of the optic position of glued transscleral fixated intraocular lens (IOL) with optical coherence tomography (OCT). Design: Prospective observational case series. Participants: Patients with a minimum 5 years' follow-up after glued IOL surgery were included. Methods: Postoperatively, IOL position was examined by anterior segment OCT (Carl Zeiss Meditec) and the scans were analyzed in 2 axes (180 degrees-0 degrees and 270 degrees-90 degrees) using MatLab (Mathworks). Best-corrected visual acuity (BCVA; Snellen's charts), Orbscan, retinoscopy, refraction, and slit-lamp biomicroscopy were performed. Main Outcome Measures: The distance between the iris margin and the anterior IOL optic (D1, D2), slope of the line across the iris and IOL, the slope ratio between the IOL and iris, IOL tilt, and optic surface changes were determined and correlated with the astigmatism and vision. Results: A total of 60 eyes (mean follow-up of 5.9 +/- 0.2 years; range, 5-6 years) were evaluated. There was a significant correlation (P = 0.000) between the slope of iris and the IOL in horizontal and vertical axes. The mean D1 and D2 were 0.94 +/- 0.36 and 0.95 +/- 0.36 mm, respectively. Nine of 60 eyes (15%) had pigment dispersed on the IOL surface. Twenty-one eyes (35%) had optic tilt detected on OCT and 65% of eyes had no optic tilt. The mean angle between the IOL and the iris was noted to be 3.2 +/- 2.7 degrees and 2.9 +/- 2.6 degrees in horizontal and vertical axes, respectively. The mean ocular residual astigmatism (ORA) was 0.53 +/- 0.5 diopters. There was no difference in the ORA between the eyes with and without tilt (P = 0.762). There was no correlation (P = 0.348) between the ORA and BCVA. Position of the IOL was not dependent on the type of lens, age of the patient, or the preoperative surgical indication. Conclusions: Long-term analysis with OCT demonstrated good IOL positioning without any significant optic tilt in patients with glued IOL fixation. (C) 2015 by the American Academy of Ophthalmology.
引用
下载
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [31] Long-Term Reproducibility of Optical Coherence Tomography Angiography in Stable Glaucomatous Eyes
    Nishida, Takashi
    Moghimi, Sasan
    Hou, Huiyuan
    Proudfoot, James A.
    David, Ryan Caezar Calaguas
    Kamalipour, Alireza
    El-Nimri, Nevin W.
    Bowd, Christopher
    Rezapour, Jasmin
    Zangwill, Linda M.
    Weinreb, Robert N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [32] Long-term and in vivo assessment of Aβ protein-induced brain atrophy in a zebrafish model by optical coherence tomography
    Lin, Yanping
    Chen, Tingru
    Mao, Guangjuan
    Qiu, Ting
    Lan, Yintao
    Xiang, Xiang
    Huang, Jie
    Huang, Jing
    Lu, Ting
    Gan, Shuqi
    Sun, Xiang-Dong
    Zhang, Jian
    JOURNAL OF BIOPHOTONICS, 2020, 13 (07)
  • [33] Will optical coherence tomography replace intravascular ultrasound in the assessment of early and long-term effects of percutaneous coronary interventions?
    Pietrasik, Arkadiusz
    Rdzanek, Adam
    Kochman, Janusz
    Szmidt, Mateusz
    Filipiak, Krzysztof J.
    Opolski, Grzegorz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2008, 4 (01): : 15 - 19
  • [34] Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer
    Wenwen He
    Xiaodi Qiu
    Shaohua Zhang
    Yu Du
    Yinglei Zhang
    Yi Lu
    Xiangjia Zhu
    Eye, 2018, 32 : 1237 - 1243
  • [35] Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer
    He, Wenwen
    Qiu, Xiaodi
    Zhang, Shaohua
    Du, Yu
    Zhang, Yinglei
    Lu, Yi
    Zhu, Xiangjia
    EYE, 2018, 32 (07) : 1237 - 1243
  • [36] Comparison of Clinical Long-Term Outcomes with Two Types of One-Piece Aspheric Intraocular Lenses after Cataract Surgery
    Park, Yong Seok
    Ji, Yong Sok
    Yoon, Kyung Chul
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (02): : 221 - 227
  • [37] Type 3 neovascularisation: long-term analysis of visual acuity and optical coherence tomography anatomical outcomes
    Chae, Bora
    Su, Daniel
    Gal-Or, Orly
    Freund, K. Bailey
    Sarraf, David
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2019, 103 (01) : 43 - 48
  • [38] ASSESSMENT OF THE LONG-TERM CORNEAL RESPONSE TO HYDROGEL INTRASTROMAL LENSES IMPLANTED IN MONKEY EYES FOR UP TO 5 YEARS
    MCDONALD, MB
    MCCAREY, BE
    STORIE, B
    BEUERMAN, RW
    SALMERON, B
    VANRIJ, G
    KNIGHT, PM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (02): : 213 - 222
  • [39] Long-Term Changes in the Coronary Artery Structure After Heart Transplantation: A Prospective Optical Coherence Tomography Study
    Bjerre, K. P.
    Clemmensen, T. S.
    Poulsen, S.
    Christiansen, E.
    Neghabat, O.
    Holm, N.
    Hvas, A.
    Grove, E. L.
    Kristensen, S. D.
    Eiskjaer, H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S127 - S127
  • [40] Fully Automated Biometry of In Situ Intraocular Lenses Using Long Scan Depth Spectral-Domain Optical Coherence Tomography
    Chen, Qi
    Leng, Lin
    Zhu, Dexi
    Wang, Yaozeng
    Shao, Yilei
    Wang, Jianhua
    Lu, Fan
    Shen, Meixiao
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (01): : 37 - 45