Comparison of speech perception performance between the Nucleus 24 and Nucleus 24 Contour cochlear implant systems

被引:10
|
作者
Bacciu, A
Pasanisi, E
Vincenti, V
Guida, M
Barbot, A
Berghenti, M
Forli, F
Berrettini, S
Bacciu, S
机构
[1] Univ Parma, Dept Otolaryngol, IT-43100 Parma, Italy
[2] Univ Pisa, Dept Otolaryngol, Pisa, Italy
关键词
cochlear implant; Contour electrode; open-set speech perception;
D O I
10.1080/00016480410018043
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective - To compare the 1-, 3-, and 6-month postoperative speech perception scores obtained by a group of subjects who received the new perimodiolar array ( Nucleus Contour) cochlear implant with those obtained by a group of subjects implanted with the straight electrodes of the previous-generation Nucleus 24 device. Material and Methods - The speech performance of 10 postlingually deafened adults implanted with the Nucleus Contour device was compared with that of matched controls who received the Nucleus 24 model. Objective measures included word and sentence speech recognition scores. Results - Patients implanted with the Nucleus Contour device obtained significantly higher word and sentence recognition scores after short-term use of the implant compared to those obtained by patients implanted with the Nucleus 24 model. Conclusion - Further long-term studies are required to determine whether the Nucleus Contour CI recipients continue to improve over time.
引用
收藏
页码:1155 / 1158
页数:4
相关论文
共 50 条
  • [31] TELEPHONE SPEECH COMPREHENSION WITH USE OF THE NUCLEUS COCHLEAR IMPLANT
    COHEN, NL
    WALTZMAN, SB
    SHAPIRO, WH
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1989, 98 (08): : 8 - 11
  • [32] Influence of ionizing radiation on nucleus 24 cochlear implants
    Klenzner, T
    Knapp, F
    Röhner, F
    von Wallenberg, E
    Mauch, H
    Pedersen, P
    Aschendorff, A
    Laszig, R
    Lutterbach, J
    OTOLOGY & NEUROTOLOGY, 2005, 26 (04) : 661 - 667
  • [33] THE EFFECTS OF LIMITING THE NUMBER OF NUCLEUS 22 COCHLEAR IMPLANT ELECTRODES PROGRAMMED ON SPEECH-PERCEPTION
    GEIER, LL
    NORTON, SJ
    EAR AND HEARING, 1992, 13 (05): : 340 - 348
  • [34] Speech perception by children with the clarion (CIS) or nucleus 22 (SPEAK) cochlear implant or hearing aids
    Meyer, TA
    Svirsky, MA
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (12): : 49 - 51
  • [35] Current speech perception benefits for adults using the nucleus 22-channel cochlear implant
    Hollow, R
    Plant, K
    Larratt, M
    Skok, M
    Whitford, L
    Dowell, R
    Clark, G
    COCHLEAR IMPLANTS, 1996, : 249 - 253
  • [36] European multi-centre study of the Nucleus Hybrid L24 cochlear implant
    Lenarz, Thomas
    James, Chris
    Cuda, Domenico
    O'Connor, Alec Fitzgerald
    Frachet, Bruno
    Frijns, Johan H. M.
    Klenzner, Thomas
    Laszig, Roland
    Manrique, Manuel
    Marx, Mathieu
    Merkus, Paul
    Mylanus, Emmanuel A. M.
    Offeciers, Erwin
    Pesch, Joerg
    Ramos-Macias, Angel
    Robier, Alain
    Sterkers, Olivier
    Uziel, Alain
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2013, 52 (12) : 838 - 848
  • [37] Preliminary experience with neural response telemetry in the Nucleus CI24M cochlear implant
    Brown, CJ
    Abbas, PJ
    Gantz, BJ
    AMERICAN JOURNAL OF OTOLOGY, 1998, 19 (03): : 320 - 327
  • [38] From Nucleus 24 to 513: Changing Cochlear Implant Design Affects Auditory Response Thresholds
    Gordon, Karen A.
    Papsin, Blake C.
    OTOLOGY & NEUROTOLOGY, 2013, 34 (03) : 436 - 442
  • [39] Comparison of Speech Perception Performance Between Sprint/Esprit 3G and Freedom Processors in Children Implanted With Nucleus Cochlear Implants
    Santarelli, Rosamaria
    Magnavita, Vincenzo
    De Filippi, Roberta
    Ventura, Laura
    Genovese, Elisabetta
    Arslan, Edoardo
    OTOLOGY & NEUROTOLOGY, 2009, 30 (03) : 304 - 312
  • [40] Hearing Preservation Outcomes with Different Cochlear Implant Electrodes: Nucleus® Hybrid™-L24 and Nucleus Freedom™ CI422
    Jurawitz, Marie-Charlot
    Buechner, Andreas
    Harpel, Theo
    Schuessler, Mark
    Majdani, Omid
    Lesinski-Schiedat, Anke
    Lenarz, Thomas
    AUDIOLOGY AND NEURO-OTOLOGY, 2014, 19 (05) : 293 - 309