A new easy camera calibration technique based on circular points

被引:129
|
作者
Meng, XQ [1 ]
Hu, ZY
机构
[1] Univ Calif Los Angeles, Dept Comp Sci, Los Angeles, CA 90095 USA
[2] Inst Automat, Natl Lab Pattern Recognit, Beijing 100080, Peoples R China
关键词
computer vision; projective geometry; circular points; camera calibration; 3D reconstruction;
D O I
10.1016/S0031-3203(02)00225-X
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Inspired by Zhang's work on flexible calibration technique, a new easy technique for calibrating a camera based on circular points is proposed. The proposed technique only requires the camera to observe a newly designed planar calibration pattern (referred to as the model plane hereinafter) which includes a circle and a pencil of lines passing through the circle's center, at a few (at least three) different unknown orientations, then all the five intrinsic parameters can be determined linearly. The main advantage of our new technique is that it needs to know neither any metric measurement on the model plane, nor the correspondences between points on the model plane and image ones, hence the whole calibration process becomes extremely simple. The proposed technique is particularly useful for those people who are not familiar with computer vision. Experiments with simulated data as well as with real images show that our new technique is robust and accurate. (C) 2002 Pattern Recognition Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1155 / 1164
页数:10
相关论文
共 50 条
  • [21] Easy and stable bronchoscope camera calibration technique for bronchoscope navigation system
    Ishitani, Kazuyoshi
    Daisuke, Deguchi
    Kitasaka, Takayuki
    Mori, Kensaku
    Suenaga, Yasuhito
    Takabatake, Hirotsugu
    Mori, Masaki
    Natori, Hiroshi
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [22] Camera calibration method based on circular array calibration board
    Chen, Haifeng
    Zhuang, Jinlei
    Liu, Bingyou
    Wang, Lichao
    Zhang, Luxian
    SYSTEMS SCIENCE & CONTROL ENGINEERING, 2023, 11 (01)
  • [23] Camera calibration method based on circular ring
    Yuan Yun
    Zhu Zhaokun
    Gui Yang
    Xie Tangtao
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN IMAGING DETECTORS AND APPLICATIONS, 2011, 8194
  • [24] Camera Calibration Based on Circular Marking Board
    Chen, Xu
    Fang, Jian-jun
    Cui, Di
    INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND COMPUTER SCIENCE (AICS 2016), 2016, : 25 - 30
  • [25] New active vision based camera self-calibration technique
    Wu, Fu-Chao
    Li, Hua
    Hu, Zhan-Yi
    Zidonghua Xuebao/Acta Automatica Sinica, 2001, 27 (06): : 752 - 762
  • [26] A new technique for camera self-calibration
    Dai, ST
    Ji, Q
    2001 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2001, : 2165 - 2170
  • [27] New Calibration Technique for a Novel Stereo Camera
    Tu, Xue
    Subbarao, Murali
    OPTICAL INSPECTION AND METROLOGY FOR NON-OPTICS INDUSTRIES, 2009, 7432
  • [28] A New Camera Calibration Technique for Serious Distortion
    Huang, Biao
    Zou, Shiping
    PROCESSES, 2022, 10 (03)
  • [29] Camera Self-calibration Based on the Vanishing Points
    Chang, Dongsheng
    Wang, Kuanquan
    Wang, Lianqing
    ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, PT III, 2011, 7004 : 47 - +
  • [30] A Camera Calibration Method Based on Plane Grid Points
    Zhang, Baofeng
    Tian, Xiuzhen
    Zhang, Xiaoling
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY, PTS 1-3, 2011, 230-232 : 723 - 727