Two-phase hollow fiber-liquid microextraction based on reverse micelle for the determination of quercetin in human plasma and vegetables samples

被引:52
|
作者
Banforuzi, Samereh Ranjbar [1 ]
Hadjmohammadi, Mohammad Reza [1 ]
机构
[1] Univ Mazandaran, Fac Chem, Dept Analyt Chem, Niroo Havayii Blvd, Babol Sar 4741695447, Iran
关键词
Hallow fiber-liquid phase microextraction; High performance liquid chromatography; Human plasma; Quercetin; Reverse micelle; Vegetables; SOLID-PHASE EXTRACTION; ALLIUM-CEPA L; HUMAN URINE; FLAVONOIDS; ONION; HPLC; CHROMATOGRAPHY; GLUCOSIDES; ANTIOXIDANT; INHIBITION;
D O I
10.1016/j.talanta.2017.05.058
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new two-phase hollow fiber-liquid microextraction based on reverse micelle as sensitive and efficient method for the extraction of quercetin in human plasma, onion and tomato samples was developed for the first time. The extraction is based on the solubilization of analyte in the aqueous core of the reverse micelle of cationic cethyltrimethyl ammonium bromide surfactant, CTAB, which are present in the organic phase and are used as acceptor phase in hollow fiber-liquid phase microextraction. Experimental results show that the electrostatic interaction between the oppositely charged surfactant head group present in the reverse micelles and the analyte molecule has a key role in the extraction. Extraction parameters including the organic phase, pH, surfactant concentrations, stirring rate, extraction time, temperature and ionic strength were optimized. The optimum condition is obtained when the variables are set to: pH= 7.5, organic solvent= 1-octanol, CTAB concentration= 7 mmollrl, stirring rate= 900 rpm at room temperature and extraction time= 30 min. Under the mentioned condition, the calibration range was found to be linear over 0.5-1000 ng mL(-1) with the limit of detection of 0.1 ng mL(-1). The extraction recovery of 97.4%, with relative standard deviation of 3.5%, was obtained via tree replicated measurements on a 15 ng L-1 quercetin standard solution. Finally, the newly developed method was successfully used for the preconcentration and determination of quercetin in plasma, onion and tomato samples.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 50 条
  • [11] Reverse Micelle Hollow Fiber Liquid-Phase Microextraction Coupled with HPLC for the Determination of Q-Markers of Anthraquinones in Rhubarb and Their Plasma Protein Binding Rates
    Shuang Hu
    Shu-mei Zhang
    Chun-lu Wang
    Xiao-ping Bi
    Xiao-hong Bai
    Chromatographia, 2020, 83 : 757 - 766
  • [12] Hollow fiber–liquid phase microextraction of barbiturates in liver samples
    Rafael Almeida Menck
    Carolina Dizioli Rodrigues de Oliveira
    Diógenes Saulo de Lima
    Ligia Endo Goes
    Vilma Leyton
    Carlos Augusto Pasqualucci
    Daniel Romero Muñoz
    Mauricio Yonamine
    Forensic Toxicology, 2013, 31 : 31 - 36
  • [13] Hollow fiber-liquid phase microextraction for trace enrichment of the residues of atrazine and its major degradation products from environmental water and human urine samples
    Megersa, Negussie
    ANALYTICAL METHODS, 2015, 7 (23) : 9940 - 9948
  • [14] Determination of Trace Chloroanilines in Environmental Water Samples Using Hollow Fiber-Based Liquid Phase Microextraction
    Young, Anna
    Lai, Guida
    Hung, Brian
    Yuen, Amy
    He, Yi
    CHROMATOGRAPHIA, 2011, 74 (1-2) : 83 - 88
  • [15] Determination of Trace Chloroanilines in Environmental Water Samples Using Hollow Fiber-Based Liquid Phase Microextraction
    Anna Young
    Guida Lai
    Brian Hung
    Amy Yuen
    Yi He
    Chromatographia, 2011, 74 : 83 - 88
  • [16] Hollow fiber liquid-phase microextraction for the determination of nimesulide in human plasma and its application to a pharmacokinetic study
    Yang, W. W.
    Zhang, H. F.
    Jia, Y. R.
    Zhao, T.
    Zhao, Y. L.
    Tong, L. J.
    Sun, L. X.
    PHARMAZIE, 2011, 66 (08): : 564 - 569
  • [17] Rapid determination of nine preservatives in tobacco flavor by three phase-hollow fiber-liquid phase microextraction- high performance liquid chromatography
    Wang, Ye
    Xie, Jianchen
    Huang, Lingjie
    Xia, Zhicheng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2024, 42 (08) : 749 - 757
  • [18] Analysis of PBDEs in Soil, Dust, Spiked Lake Water, and Human Serum Samples by Hollow Fiber-Liquid Phase Microextraction Combined with GC-ICP-MS
    Xiao, Qin
    Hu, Bin
    Duan, Jiankun
    He, Man
    Zu, Wanqing
    Journal of the American Society for Mass Spectrometry, 2007, 18 (10): : 1740 - 1748
  • [19] Chiral liquid chromatographic determination of mirtazapine in human plasma using two-phase liquid-phase microextraction for sample preparation
    de Santana, FJM
    de Oliveira, ARM
    Bonato, PS
    ANALYTICA CHIMICA ACTA, 2005, 549 (1-2) : 96 - 103
  • [20] Analysis of PBDEs in soil, dust, spiked lake water, and human serum samples by hollow fiber-liquid phase microextraction combined with GC-ICP-MS
    Xiao, Qin
    Hu, Bin
    Duan, Jiankun
    He, Man
    Zu, Wanqing
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (10) : 1740 - 1748