Accuracy of Ultrasound and Magnetic Resonance Cholangiopancreatography Findings in the Diagnosis of Biliary System Stones

被引:0
|
作者
Naji, Abdullah Taher [1 ]
Amer, Ameen Mohsen [1 ]
Alzofi, Saddam Mohammed [1 ]
Ali, Esmail Abdu [2 ]
Alnaggar, Noman Qaid [2 ]
机构
[1] Univ Sci & Technol, Dept Med Radiol & Imaging Technol, Fac Med & Hlth Sci, Sanaa, Yemen
[2] Univ Sci & Technol, Dept Biomed Engn, Fac Engn, Sanaa, Yemen
来源
关键词
Accuracy; biliary system stones; diagnosis; MRCP; ultrasound; BILE-DUCT STONES; MANAGEMENT; ENDOSCOPY; MRCP;
D O I
10.47836/pjst.30.1.46
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to evaluate the diagnostic accuracy of magnetic resonance cholangiopancreatography (MRCP) and Ultrasound (US) images for the diagnosis of biliary system stones, as well as to assess the consistency between MRCP and US findings. The study sample included 200 cases (90 males and 110 females) with symptomatic biliary system stones between 14 and 82 years. All cases underwent both the US and MRCP imaging for biliary system diagnosis. The study revealed that the most prominent age group with symptoms of biliary system stones was the 33-60-year-old group. It also found that the accuracy of US and MRCP in detecting gallbladder (GB) stones compared with the final diagnosis was 94% and 91%, respectively, with moderate conformity between their results. The accuracy of US and MRCP images in detecting common bile duct (CBD) stones was 61% and 98%, respectively, with fair conformity between their results. In addition, there is a significant agreement between the MRCP and US results in detecting the GB and CBD stones with an agreed percentage of 74% and 71%, respectively. The study concluded that US is the preferred imaging technique for patients with symptomatic gallbladder stones, whereas MRCP is a trustworthy investigation for common bile duct stones.
引用
收藏
页码:841 / 852
页数:12
相关论文
共 50 条
  • [1] Accuracy of magnetic resonance cholangiopancreatography for the diagnosis of common bile duct stones
    Norero, Enrique
    Norero, Blanca
    Huete, Alvaro
    Pimentel, Fernando
    Cruz, Francisco
    Ibanez, Luis
    Martinez, Jorge
    Jarufe, Nicolas
    REVISTA MEDICA DE CHILE, 2008, 136 (05) : 600 - 605
  • [2] A comparison of magnetic resonance cholangiopancreatography and endoscopic ultrasound in the diagnosis of CBD stones
    Brennan, DD
    Clarke, E
    Gough, V
    Bruzzi, JF
    McEntee, GP
    Fenlon, H
    RADIOLOGY, 2002, 225 : 577 - 577
  • [3] The accuracy of magnetic resonance cholangiopancreatography in the diagnosis of biliary atresia in preterm infants with cholestasis
    Chen, Wei-Che
    Lo, Hsiao-Yu
    Tsai, Yi-Shan
    Yang, Yao-Jong
    PEDIATRICS AND NEONATOLOGY, 2023, 64 (01): : 12 - 18
  • [4] The role of ultrasound and magnetic resonance cholangiopancreatography for the diagnosis of biliary stricture after liver transplantation
    Beswick, Daniel M.
    Miraglia, Roberto
    Caruso, Settimo
    Marrone, Gianluca
    Gruttadauria, Salvatore
    Zajko, Albert B.
    Luca, Angelo
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2089 - 2092
  • [5] Diagnostic accuracy of magnetic resonance cholangiopancreatography for biliary disease.
    Kitazumi, Y
    Kanozawa, S
    Anzai, T
    Iimuro, M
    Takahashi, M
    Kuwayama, H
    GASTROENTEROLOGY, 2000, 118 (04) : A452 - A452
  • [6] Accuracy of Magnetic Resonance Cholangiopancreatography in the Diagnosis of Pancreas Divisum
    Mosler, Patrick
    Akisik, F.
    Sandrasegaran, K.
    Fogel, E.
    Watkins, J.
    Alazmi, W.
    Sherman, S.
    Lehman, G.
    Imperiale, T.
    McHenry, L.
    DIGESTIVE DISEASES AND SCIENCES, 2012, 57 (01) : 170 - 174
  • [7] Accuracy of Magnetic Resonance Cholangiopancreatography in the Diagnosis of Pancreas Divisum
    Patrick Mosler
    F. Akisik
    K. Sandrasegaran
    E. Fogel
    J. Watkins
    W. Alazmi
    S. Sherman
    G. Lehman
    T. Imperiale
    L. McHenry
    Digestive Diseases and Sciences, 2012, 57 : 170 - 174
  • [8] Magnetic Resonance Cholangiopancreatography of Benign Disorders of the Biliary System
    Prabhakar, Priya D.
    Prabhakar, Anand M.
    Prabhakar, Hima B.
    Sahani, Duyshant
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2010, 18 (03) : 497 - +
  • [9] Magnetic resonance cholangiopancreatography of biliary system abnormalities in children
    Fitoz, Suat
    Erden, Ayse
    Boruban, Seda
    CLINICAL IMAGING, 2007, 31 (02) : 93 - 101
  • [10] Magnetic Resonance Cholangiopancreatography is Significantly Superior to Ultrasound in the Diagnosis of Biliary Anastomotic Strictures After Liver Transplantation
    Prabhu, Anoop
    Park, James
    Ahmad, Jawad