Left Ventricular Assist Device Inflow Cannula Angle and Thrombosis Risk

被引:73
|
作者
Chivukula, Venkat Keshav [2 ]
Beckman, Jennifer A. [1 ]
Prisco, Anthony R. [4 ]
Dardas, Todd [1 ]
Lin, Shin [1 ]
Smith, Jason W. [3 ]
Mokadam, Nahush A. [3 ]
Aliseda, Alberto [2 ]
Mahr, Claudius [1 ]
机构
[1] Univ Washington, Div Cardiol, 1959 NE Pacific St, Seattle, WA 98195 USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[3] Univ Washington, Div Cardiothorac Surg, Seattle, WA 98195 USA
[4] Univ Minnesota, Dept Med, Box 736 UMHC, Minneapolis, MN 55455 USA
关键词
cannula; heart assist devices; heart ventricles; stroke; thrombosis; CONTINUOUS-FLOW; PUMP; MANAGEMENT; TRANSPLANT; THERAPY; SYSTEM; BRIDGE;
D O I
10.1161/CIRCHEARTFAILURE.117.004325
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: As heart failure prevalence continues to increase in the setting of a static donor supply, left ventricular assist device (LVAD) therapy for end-stage heart failure continues to grow. Anecdotal evidence suggests that malalignment of the LVAD inflow cannula may increase thrombosis risk, but this effect has not been explored mechanistically or quantified statistically. Our objective is to elucidate the impact of surgical angulation of the inflow cannula on thrombogenicity. METHODS AND RESULTS: Unsteady computational fluid dynamics is used in conjunction with computational modeling and virtual surgery to model flow through the left ventricle for 5 different inflow cannula angulations. We use a holistic approach to evaluate thrombogenicity: platelet-based (Lagrangian) metrics to evaluate the platelet mechanical environment, combined with flow-based (Eulerian) metrics to investigate intraventricular hemodynamics. The thrombogenic potential of each LVAD inflow cannula angulation is quantitatively evaluated based on platelet shear stress history and residence time. Intraventricular hemodynamics are strongly influenced by LVAD inflow cannula angulation. Platelet behavior indicates elevated thrombogenic potential for certain inflow cannula angles, potentially leading to platelet activation. Our analysis demonstrates that the optimal range of inflow angulation is within 0 +/- 7 degrees of the left ventricular apical axis. CONCLUSIONS: Angulation of the inflow cannula >7 degrees from the apical axis (axis connecting mitral valve and ventricular apex) leads to markedly unfavorable hemodynamics as determined by computational fluid dynamics. Computational hemodynamic simulations incorporating Lagrangian and Eulerian metrics are a powerful tool for studying optimization of LVAD implantation strategies, with the long-term potential of improving outcomes.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Left Ventricular Assist Device Inflow Angle and Pump Positional Change Over Time Adverse Impact on Left Ventricular Assist Device Function
    Kazui, Toshinobu
    Zhang, Andrew
    Greenberg, Jason
    Itoh, Akinobu
    Tran, Phat L.
    Keith, Angela D.
    Ewald, Greg A.
    Damiano, Ralph J., Jr.
    Silvestry, Scott C.
    ANNALS OF THORACIC SURGERY, 2016, 102 (06): : 1933 - 1940
  • [32] Extending the perspective on left ventricular assist device pump thrombosis to left ventricular assist device system thrombosis
    Kormos, Robert L.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (01): : E37 - E38
  • [33] Association of Inflow Cannula Position with Left Ventricular Unloading and Clinical Outcomes in Patients with HeartMate II Left Ventricular Assist Device
    Imamura, Teruhiko
    Nguyen, Ann
    Chung, Ben
    Rodgers, Daniel
    Sarswat, Nitasha
    Kim, Gene
    Raikhelkar, Jayant
    Adatya, Sirtaz
    Ota, Takeyoshi
    Song, Tae
    Juricek, Colleen
    Estep, Jerry D.
    Burkhoff, Daniel
    Jeevanandam, Valluvan
    Sayer, Gabriel
    Uriel, Nir
    ASAIO JOURNAL, 2019, 65 (04) : 331 - 335
  • [34] Comparing left ventricular assist device inflow cannula angle between median sternotomy and thoracotomy using 3D reconstructions
    Pearman, Madeleine
    Emmanuel, Sam
    Jansz, Paul
    Watson, Alasdair
    Connellan, Mark
    Iyer, Arjun
    Barua, Sumita
    Hayward, Christopher Simon
    ARTIFICIAL ORGANS, 2023, 47 (06) : 1018 - 1028
  • [35] Novel thrombosis risk index as predictor of left ventricular assist device thrombosis
    Trivedi, Jaimin R.
    Sobieski, Michael A.
    Schwartz, Samuel
    Williams, Matthew L.
    Slaughter, Mark S.
    ASAIO Journal, 2013, 59 (04): : 380 - 383
  • [36] Novel Thrombosis Risk Index as Predictor of Left Ventricular Assist Device Thrombosis
    Trivedi, Jaimin R.
    Sobieski, Michael A.
    Schwartz, Samuel
    Williams, Matthew L.
    Slaughter, Mark S.
    ASAIO JOURNAL, 2013, 59 (04) : 380 - 383
  • [37] The Impact of Inflow Cannula Misalignment on Unloading in Patients With a Ventricular Assist Device
    Swinney, C.
    Itoh, A.
    Keith, A.
    Balsara, K.
    Silvestry, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : S28 - S28
  • [38] Transesophageal echocardiography diagnosis of extracardiac left ventricular assist device inflow cannula obstruction in a patient with thoratec intracorporeal ventricular assist device biventricular support
    Frogel, Jonathan
    Vodur, Srilatha
    Horak, Jiri
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (06) : 777.e5 - 777.e6
  • [39] Inflow cannula obstruction of the HeartWare left ventricular assist device: what do we really know?
    Pappalardo, Federico
    Bertoldi, Letizia F.
    Sanvito, Francesca
    Marini, Claudia
    Consolo, Filippo
    CARDIOVASCULAR PATHOLOGY, 2021, 50
  • [40] Utility of Echocardiography in Defining Inflow Cannula Malposition in Left Ventricular Assist Device and the Association with Adverse Outcome
    Kassi, M.
    Eshelbrennen, C.
    Amione-Guerra, J.
    Estep, J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S97 - S97