Real-time monitoring of distillations by near-infrared spectroscopy

被引:17
|
作者
Pasquini, C [1 ]
Scafi, SHF [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13084971 Campinas, SP, Brazil
关键词
D O I
10.1021/ac034054d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple device is described to couple a fast-scanning acoustooptic tunable filter-based NIR spectrophotometer to a distillation apparatus for monitoring the condensed Vapor in real time. The device consists of a small funnel whose glass neck (2-mm diameter) is bent into an "U" format to produce a flow cell of similar to 150-muL inner volume. A pair of optical fibers is used to deliver the monochromatic light and to collect the fraction passing through the glass tube. The end of the condenser of the distillation head touches the wall of the small funnel. The condensed liquid flows uncoupled from pressure changes in the interior of the distillation head. Absorbance spectra were obtained, during the distillation, as averages of 50 scans (4 s) every 5 s in the spectral range 950 - 1800 nm with nominal resolution of 2.0 mn. In the first experiments, the distillations were performed at constant power supplied to the sample (25 mL) in a microdistillation apparatus working without any type of reflux column. The usefulness of the real-time monitoring of distillation is demonstrated using some prepared binary mixtures and by comparing the distillation behavior of adulterated and regular gasoline samples. Data analysis and interpretation are facilitated by employing principal component analysis. The system accesses the composition of the condensate, which can separate and concentrate one or more compounds present in the original sample.
引用
收藏
页码:2270 / 2275
页数:6
相关论文
共 50 条
  • [41] Near-infrared spectroscopic method for real-time monitoring of pharmaceutical powders during voiding
    Barajas, Martha J.
    Cassiani, Alex Rodriguez
    Vargas, Wandylis
    Conde, Carlos
    Ropero, Jorge
    Figueroa, Jorge
    Romanach, Rodolfo J.
    APPLIED SPECTROSCOPY, 2007, 61 (05) : 490 - 496
  • [42] Can real-time near-infrared spectroscopy monitoring detect graft venous thrombosis after pediatric kidney transplantation?
    Ghidini, Filippo
    Parolin, Mattia
    De Corti, Federica
    Amigoni, Angela
    Leon, Francesco Fascetti
    Benetti, Elisa
    Gamba, Piergiorgio
    PEDIATRIC TRANSPLANTATION, 2022, 26 (03)
  • [43] Real-time monitoring of granule properties during high shear wet granulation by near-infrared spectroscopy with a chemometrics approach
    Shikata, F.
    Kimura, S.
    Hattori, Y.
    Otsuka, M.
    RSC ADVANCES, 2017, 7 (61): : 38307 - 38317
  • [44] In situ real-time monitoring of epoxy/amine kinetics by remote near infrared spectroscopy
    Mijovic, J
    Andjelic, S
    Kenny, JM
    POLYMERS FOR ADVANCED TECHNOLOGIES, 1996, 7 (01) : 1 - 16
  • [45] Characterization of a hybrid diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy system for real-time monitoring of cerebral blood flow and oxygenation
    Verdecchia, K.
    Diop, M.
    Lee, A.
    St Lawrence, K.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XIII, 2015, 9313
  • [46] Real time in-line monitoring of large scale Bacillus fermentations with near-infrared spectroscopy
    Alves-Rausch, Jose
    Bienert, Roland
    Grimm, Christian
    Bergmaier, Dirk
    JOURNAL OF BIOTECHNOLOGY, 2014, 189 : 120 - 128
  • [47] NEAR-INFRARED SPECTROSCOPY IN FETAL MONITORING
    OBRIEN, PMS
    DOYLE, PM
    ROLFE, P
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 1993, 49 (07): : 483 - &
  • [48] Quantitative real-time release testing of rhubarb based on near-infrared spectroscopy and method validation
    Zhang, Siyu
    Ma, Hui
    Pan, Hongye
    Shao, Qianwen
    Liu, Xuesong
    Wu, Yongjiang
    VIBRATIONAL SPECTROSCOPY, 2019, 104
  • [49] Real-Time Display of Dense Neuronal Activation Map Using Functional Near-Infrared Spectroscopy
    Yaqub, M. Atif
    Ghafoor, Usman
    Hong, Keum-Shik
    2019 INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION IN INDUSTRY (ICRAI), 2019,
  • [50] Effectiveness Evaluation of Real-Time Scalp Signal Separating Algorithm on Near-Infrared Spectroscopy Neurofeedback
    Ung, Wei Chun
    Funane, Tsukasa
    Katura, Takusige
    Sato, Hiroki
    Tang, Tong Boon
    Hani, Ahmad Fadzil M.
    Kiguchi, Masashi
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (04) : 1148 - 1156