Evaluation of undifferentiated carcinoma of nasopharyngeal type with thallium-201 and technetium-99m MIBI SPECT

被引:3
|
作者
Sobic-Saranovic, Dragana P.
Pendjer, Lvica P.
Kozarevic, Neboisa Dj.
Artiko, Vera M.
Mikic, Anton A.
Obradovic, Vladimir B.
机构
[1] Clin Ctr Serbia, Inst Nucl Med, Belgrade 11000, Serbia
[2] Clin Ctr Serbia, Inst Otolaryngol, Belgrade 11000, Serbia
关键词
D O I
10.1016/j.otohns.2007.03.026
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
OBJECTIVE: To determine the value of 201-thallium (201-Tl) and technetium-99m sestamibi (Tc-99m MIBI) single photon emission computed tomography (SPECT) for detecting primary undifferentiated carcinoma of nasopharyngeal type (UCNT), residual/recurrent tissue, and lymph node involvement. STUDY DESIGN AND SETTING: SPECT of head and neck was prospectively performed in 46 patients with a history of, UCNT (201-Tl in 24 patients, Tc-99m MIBI in 22). CT/MRI findings. clinical follow-up, and pathohistological verification served as a gold standard for calculating sensitivity, specificity, and accuracy of each scintigraphic technique. Tumor-to-background index (T/Bg) was derived when SPECT findings were positive. RESULTS: Sensitivity of 201-Tl SPECT was 87 percent, with 78 percent specificity. 83 percent accuracy, and T/Bg of 4.05 +/- 1.50. Tc-99m MIBI SPECT had 85 percent sensitivity, 78 percent specificity, 82 percent accuracy. and T/Bg of 4.45 +/- 1.27. CONCLUSION AND SIGNIFICANCE: 201-Tl SPECT and Tc-99m MIBI SPECT are useful for detecting primary UCNT, residual/recurrent disease. and lymph node involvement. This use is particularly valuable after chemoradiotherapy when CT/MRI may be ambiguous. (c) 2007 American Academy of Otolarynlgololgy-Head and Neck Surgery Foundation. All rights reserved.
引用
收藏
页码:405 / 411
页数:7
相关论文
共 50 条
  • [21] ULTRASTRUCTURAL HISTOLOGY CORRELATES WITH RESULTS OF THALLIUM-201/TECHNETIUM-99M PARATHYROID SUBTRACTION SCINTIGRAPHY
    SANDROCK, D
    MERINO, MJ
    NORTON, JA
    NEUMANN, RD
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (01) : 24 - 29
  • [22] Diagnostic accuracy of simultaneous acquisition of transmission and emission data with technetium-99m transmission source on thallium-201 myocardial SPECT
    Ohyama, Y
    Tomiguchi, S
    Kira, T
    Kira, M
    Tsuji, A
    Kojima, A
    Matsumoto, M
    Takahashi, M
    Inobe, Y
    Yasue, H
    ANNALS OF NUCLEAR MEDICINE, 2001, 15 (01) : 21 - 26
  • [23] Diagnostic accuracy of simultaneous acquisition of transmission and emission data with technetium-99m transmission source on thallium-201 myocardial SPECT
    Yoichi Ohyama
    Seiji Tomiguchi
    Tomohiro Kira
    Mitsuko Kira
    Akinori Tsuji
    Akihiro Kojima
    Masanori Matsumoto
    Mutsumasa Takahashi
    Yoshito Inobe
    Hirofumi Yasue
    Annals of Nuclear Medicine, 2001, 15 : 21 - 26
  • [24] Extraction and retention of technetium-99m Q12, technetium-99m sestamibi, and thallium-201 in isolated rat heart during coronary acidemia
    McGoron, AJ
    Gerson, MC
    Biniakiewicz, DS
    Roszell, NJ
    Washburn, LC
    Millard, RW
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (12) : 1479 - 1486
  • [25] Extraction and retention of technetium-99m Q12, technetium-99m sestamibi, and thallium-201 in isolated rat heart during coronary acidemia
    Anthony J. McGoron
    Myron C. Gerson
    Danuta S. Biniakiewicz
    Nancy J. Roszell
    Lee C. Washburn
    Ronald W. Millard
    European Journal of Nuclear Medicine, 1997, 24 : 1479 - 1486
  • [26] A comparison of the overall first-pass kinetics of thallium-201 and technetium-99m MIBI in normoxic and low-flow ischaemic myocardium
    Adey Ayalew
    Pierre Y. Marie
    Patrick Menu
    Paul M. Mertes
    Nathalie Hassan
    Nicolas Danchin
    Pierre Olivier
    Gilles Karcher
    Alain Bertrand
    European Journal of Nuclear Medicine, 2000, 27 : 1632 - 1640
  • [27] Multiexpert blinded interpretation of electrocardiogram-gated SPECT imaging in women: Relative performance of Thallium-201 and Technetium-99m sestamibi
    Bateman, TM
    Wackers, FJT
    Mieres, JH
    Moutray, KL
    Case, JA
    Hertenstein, GJ
    House, JA
    Cullom, SJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 323A - 324A
  • [28] A comparison of the overall first-pass kinetics of thallium-201 and technetium-99m MIBI in normoxic and low-flow ischaemic myocardium
    Ayalew, A
    Marie, PY
    Menu, P
    Mertes, PM
    Hassan, N
    Danchin, N
    Olivier, P
    Karcher, G
    Bertrand, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2000, 27 (11) : 1632 - 1640
  • [29] Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands
    Alessandro Giordano
    Paola Marozzi
    Guido Meduri
    Umberto Ficola
    Maria Lucia Calcagni
    Angelo Vaccaro
    Giuseppe Rubini
    Marco Attard
    Maria Li Puma
    Riccardo Ricci
    Salvatore Corsello
    European Journal of Nuclear Medicine, 1999, 26 : 907 - 911
  • [30] Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands
    Giordano, Alessandro
    Marozzi, Paola
    Meduri, Guido
    Ficola, Umberto
    Calcagni, Maria Lucia
    Vaccaro, Angelo
    Rubini, Giuseppe
    Attard, Marco
    Li Puma, Maria
    Ricci, Riccardo
    Corsello, Salvatore
    European Journal of Nuclear Medicine and Molecular Imaging, 1999, 26 (08): : 907 - 911