Calibration-free wavelength modulation spectroscopy for gas concentration measurements using a quantum cascade laser

被引:17
|
作者
Wei, Min [1 ,2 ]
Kan, RuiFeng [1 ]
Chen, Bing [1 ]
Xu, ZhenYu [1 ]
Yang, ChenGuang [1 ]
Chen, Xiang [1 ,2 ]
Xia, HuiHui [1 ,2 ]
Hu, Mai [1 ]
He, Yabai [1 ]
Liu, JianGuo [1 ]
Fan, Xueli [1 ]
Wang, Wei [1 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230022, Anhui, Peoples R China
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2017年 / 123卷 / 05期
基金
中国国家自然科学基金;
关键词
TUNABLE DIODE-LASER; WATER CONCENTRATION; ABSORPTION; SENSOR; TEMPERATURE; SPECTROMETER; METHANE; H2O; CO;
D O I
10.1007/s00340-017-6678-y
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report the development of an accurate calibration-free wavelength-scanned wavelength modulation spectroscopy system based on the temporal wavelength response of a current-modulated quantum cascade laser (QCL) for gas concentration detections. Accurate measurements and determination of the QCL output intensity and wavelength response to current modulation enabled calculations of 1f-normalized 2f signal to obtain spectroscopic information with and without gas absorption in the beam path. The gas concentration was retrieved by fitting a simulation spectrum based on spectral line parameters to the background-subtracted 1f-normalized 2f signal based on measurements. In this paper, we demonstrate the performance of the developed system for the CH4 detection by applying an infrared QCL (at similar to 7.84 mu m or similar to 1275 cm(-1)) to probe its two infrared transition lines at 1275.042 cm(-1) and 1275.387 cm(-1). The experimental results indicated very good agreements between measurements and modeling, for integrated absorbance ranging from 0.0057 cm(-1) to 0.11 cm(-1) (or absorbance ranging from similar to 0.029 to similar to 0.57). The extracted integrated absorbance was highly linear (R = 0.99996) to the gas sample concentration. Deviations between the nominal sample gas concentrations and the extracted gas concentrations calculated based on HITRAN spectroscopic parameters were within 3.5%.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Calibration-free wavelength modulation spectroscopy: symmetry approach and residual amplitude modulation normalization
    Behera, Amiya
    Wang, Anbo
    APPLIED OPTICS, 2016, 55 (16) : 4446 - 4455
  • [22] Calibration-Free Gas Quantification through Wavelength Modulation Spectroscopy in the Millimeter-Wave/Terahertz Range
    Stanley, Victoria
    Rothbart, Nick
    Huebers, Heinz-Wilhelm
    2021 46TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER AND TERAHERTZ WAVES (IRMMW-THZ), 2021,
  • [23] Calibration-free wavelength-modulation spectroscopy based on a swiftly determined wavelength-modulation frequency response function of a DFB laser
    Zhao, Gang
    Tan, Wei
    Hou, Jiajia
    Qiu, Xiaodong
    Ma, Weiguang
    Li, Zhixin
    Dong, Lei
    Zhang, Lei
    Yin, Wangbao
    Xiao, Liantuan
    Axner, Ove
    Jia, Suotang
    OPTICS EXPRESS, 2016, 24 (02): : 1723 - 1733
  • [24] Pressure Correction for Calibration-Free Measurement of Wavelength Modulation Spectroscopy in Atmospheric Environment
    Li Jin-yi
    Fan Hong-qing
    Tian Xin-li
    Li Hong-lian
    Wu Zhi-chao
    Song Li-mei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (05) : 1407 - 1412
  • [25] Calibration-free wavelength modulation spectroscopy based on even-order harmonics
    Wang, Yihong
    Zhou, Bin
    Liu, Chang
    OPTICS EXPRESS, 2021, 29 (17): : 26618 - 26633
  • [26] Calibration-free wavelength modulation spectroscopy approach for practical logging measurements of methane slip on natural gas-powered cargo ferries
    Jaeger, Nicolas s. b.
    Mhanna, Mhanna
    Rochussen, Jeremy
    Kirchen, Patrick
    APPLIED OPTICS, 2025, 64 (04) : 1028 - 1035
  • [27] Quantum cascade laser-based wavelength modulation spectroscopy
    Chakraborty, Arup Lal
    2020 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP) AND INTERNATIONAL CONFERENCE ON INFORMATION PHOTONICS AND OPTICAL COMMUNICATIONS (IPOC), 2020,
  • [28] Fitting of calibration-free scanned-wavelength-modulation spectroscopy spectra for determination of gas properties and absorption lineshapes
    Goldenstein, Christopher S.
    Strand, Christopher L.
    Schultz, Ian A.
    Sun, Kai
    Jeffries, Jay B.
    Hanson, Ronald K.
    APPLIED OPTICS, 2014, 53 (03) : 356 - 367
  • [29] Direct and wavelength modulation spectroscopy using a cw external cavity quantum cascade laser
    Hancock, G.
    van Helden, J. H.
    Peverall, R.
    Ritchie, G. A. D.
    Walker, R. J.
    APPLIED PHYSICS LETTERS, 2009, 94 (20)
  • [30] Determination of a brass alloy concentration composition using calibration-free laser-induced breakdown spectroscopy
    M. Achouri
    T. Baba-Hamed
    S. A. Beldjilali
    A. Belasri
    Plasma Physics Reports, 2015, 41 : 758 - 768