Dosimetric guidance on using brachytherapy (LDR or HDR) to offset a flawed permanent prostate implant

被引:0
|
作者
Zaider, M. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, New York, NY 10021 USA
关键词
D O I
10.1118/1.2760839
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To provide practical dosimetric advice on mending suboptimal permanent implants using low dose‐rate (LDR) or high dose‐rate (HDR) brachytherapy (BRT). The problem is to make the combination of the two radiation treatments (the initial, flawed one and the compensatory boost) clinically isoeffective with the planned dose. Methods: The device of isoeffective dose (IED) is the appropriate tool for this purpose as it accounts for the physical (temporal distribution of dose) and biological (radiosensitivity, repair kinetics, proliferation rate) treatment setting. Results: I give, as a function of separation time from the initial, flawed treatment, and stratified by risk group representative values for the additional dose (LDR or HDR) needed to make the combined treatment isoeffective with a prescription of 144 Gy of permanently‐implanted [formula omitted] seeds. Conclusions: While the IED concept, within the constraints stated in the presentation, is rigorously valid, its practical implementation depends importantly on the relevant radiobiological parameters, and in this respect the reader is urged to use his own critical judgment. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2442 / 2442
页数:1
相关论文
共 50 条
  • [21] Permanent implant prostate cancer brachytherapy
    Cosset, J. -M.
    Flam, T.
    Thiounn, N.
    Pontvert, D.
    Pierrat, N.
    Vallancien, G.
    Chauvein, L.
    CANCER RADIOTHERAPIE, 2008, 12 (6-7): : 503 - 511
  • [22] PROSTATE LDR BRACHYTHERAPY WHITH PERMANENT I-125 SEEDS IMPLANT: RESULTS OF A RETROSPECTIVE ANALYSIS
    Chiumento, C.
    Montagna, A.
    Castaldo, G.
    Lapadula, L.
    Pedicini, P.
    Imbriani, E.
    Fusco, V
    ANNALS OF ONCOLOGY, 2009, 20
  • [23] Nomogram as an Efficient Dosimetric Verification Tool in HDR Prostate Brachytherapy
    Liang, J.
    Todor, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3626 - 3626
  • [24] LDR versus HDR brachytherapy boost in prostate cancer patients - a retrospective analysis
    Rodda, S.
    Murray, L.
    Bottomley, D.
    Bownes, P.
    Wilkinson, C.
    Adiotomre, E.
    Al-Qaisieh, B.
    Dugdale, E.
    Hulson, O.
    Mason, J.
    Smith, J.
    Henry, A. M.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S587 - S587
  • [25] Salvage Brachytherapy in Prostate Cancer after Radiation Failure: HDR vs LDR
    Henriquez Lopez, I.
    Gonzalez, C.
    Olivera Vegas, J.
    Gutierrez, C.
    Cabeza Rodriguez, M. D. L. A.
    Valero Albarran, J.
    Rodriguez Villalba, S.
    Hervas, A.
    Sancho Pardo, G.
    Alvarez Gonzalez, A.
    Zapatero, A.
    Cuesta-Alvaro, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E117 - E118
  • [26] Large-scale Retrospective Monte Carlo Dosimetric Study for Permanent Implant Prostate Brachytherapy
    Miksys, Nelson
    Vigneault, Eric
    Martin, Andre-Guy
    Beaulieu, Luc
    Thomson, Rowan M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 97 (03): : 606 - 615
  • [27] Prostate brachytherapy with permanent iodine (125I) seed implant (LDR) - intermediate biochemical results and complications
    Harza, M.
    Dudu, C.
    Iordache, A.
    Voinea, S.
    Pavel, C.
    Gingu, C.
    Serbanescu, B.
    Chibelean, C.
    Surcel, C.
    Preda, A.
    Baston, C.
    Stefan, B.
    Haineala, B.
    Anghel, R.
    Vasile, M.
    Domnisor, L.
    Rebegea, L.
    Radulescu, M. F.
    Sinescu, I.
    EUROPEAN UROLOGY SUPPLEMENTS, 2009, 8 (08) : 688 - 688
  • [28] DOSIMETRIC EVALUATION OF STABILIZING NEEDLES AND SEMINAL VESICLE IMPLANTS FOR LDR PROSTATE BRACHYTHERAPY
    Tam, T.
    Dayes, I.
    Davis, I.
    Myler, U.
    Parpia, S.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S41 - S42
  • [29] LDR Prostate Brachytherapy: Dosimetric Evaluation of Stabilizing Needles and Seminal Vesicle Implants
    Tam, T. Y.
    Dayes, I. S.
    Davis, I.
    Myler, U.
    Parpia, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S353 - S353
  • [30] Is high-dose rate (HDR) "better than" and low-dose rate (LDR) prostate brachytherapy? A dosimetric study using retrospective data.
    Sankreacha, R
    Morton, G
    Al-Hebshi, A
    MEDICAL PHYSICS, 2005, 32 (06) : 1957 - 1957