Performance enhancement of a dual heat pipe array based evacuated tube solar water heater for north eastern India climatic condition: A numerical approach

被引:12
|
作者
Tamuli, Bhaskar Ranjan [1 ]
Nath, Sujit [1 ]
Bhanja, Dipankar [1 ]
机构
[1] Natl Inst Technol Silchar, Dept Mech Engn, Silchar 788010, Assam, India
关键词
Evacuated tube collector; Micro heat pipe array; Solar radiation; Seasonal variation; Transient study; THERMAL PERFORMANCE; STORAGE-SYSTEM; AIR COLLECTOR; TEMPERATURE; ENERGY; TANK;
D O I
10.1016/j.applthermaleng.2022.118597
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat pipes have been employed widely in solar collectors for more efficient heat transfer process. In recent times, heat pipes have been modified and micro heat pipe array has been developed with higher heat transfer characteristics. Current investigation adopted the new innovations to develop a micro heat pipe array based evacuated tube solar water heater. Outputs of solar collectors are dependent on fluctuating solar radiation, which needs to be accounted for in the analysis. To simulate the practical condition, a transient numerical study was carried out to assess the performance of such a collector with special reference to the location of Silchar, NorthEast India and hence actual solar radiation data for different months is considered for the analysis accounting the seasonal variation over the year. Results indicate that the efficiency is low in the morning session but eventually stabilized around 70-80% for the most part of the day. The output water temperature of the solar collector follows the same trend of the solar radiation curve where February month yields the highest output temperature and June month registering the lowest with approximately 5 K temperature difference between them at their respective peak points. There is unutilized heat trapped inside the evacuated tube collector, which the micro heat pipe array is unable to extract. One novel geometrical modification is adopted in the present study by incorporating two micro heat pipe arrays inside the evacuated tube collector, and the simulated results show that double micro heat pipe arrays could effectively penetrate the high temperature region to extract energy. The addition of one additional micro heat pipe array could result in 15-20% efficiency enhancement.
引用
收藏
页数:14
相关论文
共 45 条
  • [41] Viable-feasibility of innovated combined condenser over traditional individual condenser heat pipe solar evacuated tube water heating system: a comparative-conclusive approach
    Nema, Garima
    Karunamurthy, K.
    WORLD JOURNAL OF ENGINEERING, 2024,
  • [42] Performance investigation of an integrated collector-storage solar water heater based on lap-joint-type micro-heat pipe arrays
    Wang, Zeyu
    Diao, Yanhua
    Zhao, Yaohua
    Yin, Lili
    Chen, Chuanqi
    Liang, Lin
    Wang, Tengyue
    APPLIED THERMAL ENGINEERING, 2019, 153 : 808 - 827
  • [43] Performance characterization of a solar-powered shell and tube heat exchanger utilizing MWCNTs/water-based nanofluids: An experimental, numerical, and artificial intelligence approach
    Said, Zafar
    Rahman, Shek
    Sharma, Prabhakar
    Hachicha, Ahmed Amine
    Issa, Salah
    APPLIED THERMAL ENGINEERING, 2022, 212
  • [44] Performance investigation of an innovative design of a small sized single glazed solar PV/T water collector for the climatic condition of a site in North East India: An experimental study
    Podder, Bishal
    Biswas, Agnimitra
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021, 43 (22) : 2983 - 2995
  • [45] Numerical analysis of the thermo-hydraulic performance and entropy generation rate of a water-in-glass evacuated tube solar collector using TiO2 water-based nanofluid and only water as working fluids
    Lopez-Nunez, Oscar A.
    Alfaro-Ayala, J. Arturo
    Ramirez-Minguela, J. J.
    Banda, Fernando Cano-
    Ruiz-Camacho, B.
    Belman-Flores, Juan Manuel