Whole Brain Perfused Blood Volume CT: Visualization of Infarcted Tissue Compared to Quantitative Perfusion CT

被引:12
|
作者
Wittkamp, Gunnar [1 ]
Buerke, Boris [1 ]
Dziewas, Rainer [2 ]
Ditt, Hendrik [3 ]
Seidensticker, Peter [4 ]
Heindel, Walter [1 ]
Kloska, Stephan P. [1 ]
机构
[1] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[2] Univ Munster, Dept Neurol, D-48149 Munster, Germany
[3] Siemens AG, Healthcare Sector, Forchheim, Germany
[4] Bayer Schering Pharma AG, BU Diagnost Imaging, Berlin, Germany
关键词
Perfused blood volume; cerebral blood volume; computed tomography; cerebral ischemia; ACUTE ISCHEMIC-STROKE; 3-DIMENSIONAL FUNCTIONAL CT; COMPUTED-TOMOGRAPHY; CEREBRAL-ISCHEMIA; CLINICAL-APPLICATION; MULTIDETECTOR CT; PENUMBRA; CORE; ANGIOGRAPHY; PERMEABILITY;
D O I
10.1016/j.acra.2009.11.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: This study determines the value of whole brain color-coded three-dimensional perfused blood volume (PBV) computed tomography (CT) for the visualization of the infarcted tissue in acute stroke patients. Materials and Methods: Nonenhanced CT (NECT), perfusion CT (PCT), and CT angiography (CTA) in 48 patients with acute ischemic stroke were performed. Whole brain PBV was calculated from NECT and CTA data sets using commercial software. PBV slices in identical orientation to the PCT slices were reconstructed and the area of visual perfusion abnormality on PBV maps was measured. The infarct core in the corresponding PCT slices (CBV <2.0 mL/100 g) was measured automatically with commercial software. The ischemic area on PBV and the infarct core on quantitative PCT were compared using the Pearsons-R correlation coefficient. Significance was considered for P < .05. Results: The quantitative PCT demonstrated a mean infarct core volume of 35.48 +/- 32.17 cm(3), whereas the volume of visual perfusion abnormality of the corresponding PBV slices was 37.16 +/- 37.59 cm(3). The perfusion abnormality in PBV was highly correlated with the infarct core of quantitative PCT for area per slice (r = 0.933, P < .01) as well as volume (r = 0.922, P < .01). Conclusions: PBV can serve as surrogate marker corresponding to the infarct core in acute stroke with whole brain coverage.
引用
收藏
页码:427 / 432
页数:6
相关论文
共 50 条
  • [41] Defining Core and Penumbra in Ischemic Stroke: A Voxel- and Volume-Based Analysis of Whole Brain CT Perfusion
    Yu, Yannan
    Han, Quan
    Ding, Xinfa
    Chen, Qingmeng
    Ye, Keqi
    Zhang, Sheng
    Yan, Shenqiang
    Campbell, Bruce C. V.
    Parsons, Mark W.
    Wang, Shaoshi
    Lou, Min
    SCIENTIFIC REPORTS, 2016, 6
  • [42] Improved Arterial Visualization in Cerebral CT Perfusion-Derived Arteriograms Compared with Standard CT Angiography: A Visual Assessment Study
    Mendrik, A. M.
    Vonken, E. P. A.
    de Kort, G. A. P.
    van Ginneken, B.
    Smit, E. J.
    Viergever, M. A.
    Prokop, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (11) : 2171 - 2177
  • [43] Automated Subtraction CT Angiography for Visualization of the Whole Brain Vasculature: A Feasibility Study
    Li, Qi
    Lv, Fajin
    Wei, Youdong
    Luo, Tianyou
    Xie, Peng
    ACADEMIC RADIOLOGY, 2013, 20 (08) : 1009 - 1014
  • [44] Whole Brain CT Perfusion in Suspected Transient Ischemic Attack and Minor Stroke
    Krishnamurthy, V
    Bivard, A.
    Lin, L.
    Spratt, N.
    Levi, C.
    Parsons, M.
    CEREBROVASCULAR DISEASES, 2016, 42 : 11 - 11
  • [45] Whole-Brain CT Perfusion to Quantify Acute Ischemic Penumbra and Core
    Lin, Longting
    Bivard, Andrew
    Krishnamurthy, Venkatesh
    Levi, Christopher R.
    Parsons, Mark W.
    RADIOLOGY, 2016, 279 (03) : 876 - 887
  • [46] Whole brain CT perfusion imaging at the early stage of aneurysmal subarachnoid haemorrhage
    Chen, Weijian
    Li, Rui
    Duan, Yuxia
    Liu, Jinjin
    Yang, Yunjun
    Zhuge, Qichuan
    BRAIN INJURY, 2016, 30 (5-6) : 513 - 514
  • [47] Intramyocardial capillary blood volume estimated by whole-body CT - validation by micro-CT
    Dong, Yue
    Beighley, Patricia E.
    Eaker, Diane R.
    Zamir, Mair
    Ritman, Erik L.
    MEDICAL IMAGING 2008: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2008, 6916
  • [48] CT Detection of Myocardial Blood Volume Deficits: Dual-Energy CT Compared With Single-Energy CT Spectra
    Arnoldi, Elisabeth
    Ruzsics, Balazs
    Lee, Yeong Shyan
    Gebregziabher, Mulugeta
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Costello, Philip
    Schoepf, U. Joseph
    CIRCULATION, 2009, 120 (18) : S375 - S375
  • [49] CT detection of myocardial blood volume deficits: Dual-energy CT compared with single-energy CT spectra
    Arnoldi, Elisabeth
    Lee, Yeong Shyan
    Ruzsics, Balazs
    Weininger, Markus
    Spears, J. Reid
    Rowley, Christopher P.
    Chiaramida, Salvatore A.
    Costello, Philip
    Reiser, Maximilian F.
    Schoepf, U. Joseph
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (06) : 421 - 429
  • [50] Comparison of lung perfusion scan and blood perfusion volume (PBV-CT) in emphysematous patients
    Burroni, L.
    Borgheresi, A.
    Palucci, A.
    Fringuelli, F. M.
    Biscontini, G.
    Romagnolo, C.
    Cottignoli, C.
    Carotti, M.
    Balducci, S.
    Cesari, E.
    Giovagnoni, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S353 - S354