Whole Brain Perfused Blood Volume CT: Visualization of Infarcted Tissue Compared to Quantitative Perfusion CT

被引:12
|
作者
Wittkamp, Gunnar [1 ]
Buerke, Boris [1 ]
Dziewas, Rainer [2 ]
Ditt, Hendrik [3 ]
Seidensticker, Peter [4 ]
Heindel, Walter [1 ]
Kloska, Stephan P. [1 ]
机构
[1] Univ Munster, Dept Clin Radiol, D-48149 Munster, Germany
[2] Univ Munster, Dept Neurol, D-48149 Munster, Germany
[3] Siemens AG, Healthcare Sector, Forchheim, Germany
[4] Bayer Schering Pharma AG, BU Diagnost Imaging, Berlin, Germany
关键词
Perfused blood volume; cerebral blood volume; computed tomography; cerebral ischemia; ACUTE ISCHEMIC-STROKE; 3-DIMENSIONAL FUNCTIONAL CT; COMPUTED-TOMOGRAPHY; CEREBRAL-ISCHEMIA; CLINICAL-APPLICATION; MULTIDETECTOR CT; PENUMBRA; CORE; ANGIOGRAPHY; PERMEABILITY;
D O I
10.1016/j.acra.2009.11.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: This study determines the value of whole brain color-coded three-dimensional perfused blood volume (PBV) computed tomography (CT) for the visualization of the infarcted tissue in acute stroke patients. Materials and Methods: Nonenhanced CT (NECT), perfusion CT (PCT), and CT angiography (CTA) in 48 patients with acute ischemic stroke were performed. Whole brain PBV was calculated from NECT and CTA data sets using commercial software. PBV slices in identical orientation to the PCT slices were reconstructed and the area of visual perfusion abnormality on PBV maps was measured. The infarct core in the corresponding PCT slices (CBV <2.0 mL/100 g) was measured automatically with commercial software. The ischemic area on PBV and the infarct core on quantitative PCT were compared using the Pearsons-R correlation coefficient. Significance was considered for P < .05. Results: The quantitative PCT demonstrated a mean infarct core volume of 35.48 +/- 32.17 cm(3), whereas the volume of visual perfusion abnormality of the corresponding PBV slices was 37.16 +/- 37.59 cm(3). The perfusion abnormality in PBV was highly correlated with the infarct core of quantitative PCT for area per slice (r = 0.933, P < .01) as well as volume (r = 0.922, P < .01). Conclusions: PBV can serve as surrogate marker corresponding to the infarct core in acute stroke with whole brain coverage.
引用
收藏
页码:427 / 432
页数:6
相关论文
共 50 条
  • [1] Whole-brain CT perfusion measurement of perfused cerebral blood volume in acute ischemic stroke: Probability curve for regional infarction
    Hunter, GJ
    Silvennoinen, HM
    Hamberg, LM
    Koroshetz, WJ
    Buonanno, FS
    Schwamm, LH
    Rordorf, GA
    Gonzalez, RG
    RADIOLOGY, 2003, 227 (03) : 725 - 730
  • [2] Whole Brain CT Perfusion Maps
    Maule, Petr
    Kleckova, Jana
    Rohan, Vladimir
    2009 FOURTH INTERNATIONAL CONFERENCE ON SYSTEMS (ICONS), 2009, : 247 - +
  • [3] CT angiography with whole brain perfused blood volume imaging - Added clinical value in the assessment of acute stroke
    Ezzeddine, MA
    Lev, MH
    McDonald, CT
    Rordorf, G
    Oliveira-Filho, J
    Aksoy, FG
    Farkas, J
    Segal, AZ
    Schwamm, LH
    Gonzalez, RG
    Koroshetz, WJ
    STROKE, 2002, 33 (04) : 959 - 966
  • [4] Quantitative Dose Dependency Analysis of Whole-Brain CT Perfusion Imaging
    Manniesing, Rashindra
    Oei, Marcel T. H.
    van Ginneken, Bram
    Prokop, Mathias
    RADIOLOGY, 2016, 278 (01) : 190 - 197
  • [5] Pulmonary Perfused Blood Volume with Dual-Energy CT as Surrogate for Pulmonary Perfusion Assessed with Dynamic Multidetector CT
    Fuld, Matthew K.
    Halaweish, Ahmed F.
    Haynes, Susan E.
    Divekar, Abhay A.
    Guo, Junfeng
    Hoffman, Eric A.
    RADIOLOGY, 2013, 267 (03) : 747 - 756
  • [6] Color-coded perfused blood volume imaging using multidetector CT: initial results of whole-brain perfusion analysis in acute cerebral ischemia
    Kloska, Stephan P.
    Fischer, Tobias
    Nabavi, Darius G.
    Dittrich, Ralf
    Ditt, Hendrik
    Klotz, Ernst
    Fischbach, Roman
    Ringelstein, Bernd
    Heindel, Walter
    EUROPEAN RADIOLOGY, 2007, 17 (09) : 2352 - 2358
  • [7] Color-coded perfused blood volume imaging using multidetector CT: initial results of whole-brain perfusion analysis in acute cerebral ischemia
    Stephan P. Kloska
    Tobias Fischer
    Darius G. Nabavi
    Ralf Dittrich
    Hendrik Ditt
    Ernst Klotz
    Roman Fischbach
    E. Bernd Ringelstein
    Walter Heindel
    European Radiology, 2007, 17 : 2352 - 2358
  • [8] Defining acute ischemic stroke tissue pathophysiology with whole brain CT perfusion
    Bivard, A.
    Levi, C.
    Krishnamurthy, V.
    Hislop-Jambrich, J.
    Salazar, P.
    Jackson, B.
    Davis, S.
    Parsons, M.
    JOURNAL OF NEURORADIOLOGY, 2014, 41 (05) : 307 - 315
  • [9] Quantitative Tissue Blood Flow Measurement of the Liver Parenchyma: Comparison Between Xenon CT and Perfusion CT
    Kazuhiko Hashimoto
    Takamichi Murakami
    Keizo Dono
    Masatoshi Hori
    Tonsok Kim
    Masayuki Kudo
    Shigeru Marubashi
    Atsushi Miyamoto
    Yutaka Takeda
    Hiroaki Nagano
    Koji Umeshita
    Hironobu Nakamura
    Morito Monden
    Digestive Diseases and Sciences, 2007, 52 : 943 - 949
  • [10] Quantitative tissue blood flow measurement of the liver parenchyma: Comparison between xenon CT and perfusion CT
    Hashimoto, Kazuhiko
    Murakami, Takamichi
    Dono, Keizo
    Hori, Masatoshi
    Kim, Tonsok
    Kudo, Masayuki
    Marubashi, Shigeru
    Miyamoto, Atsushi
    Takeda, Yutaka
    Nagano, Hiroaki
    Umeshita, Koji
    Nakamura, Hironobu
    Monden, Morito
    DIGESTIVE DISEASES AND SCIENCES, 2007, 52 (04) : 943 - 949