Automated Detection of Vascular Leakage in Fluorescein Angiography - A Proof of Concept

被引:5
|
作者
Young, LeAnne H. [1 ,2 ]
Kim, Jongwoo [3 ]
Yakin, Mehmet [1 ]
Lin, Henry [1 ]
Dao, David T. [1 ]
Kodati, Shilpa [1 ]
Sharma, Sumit [4 ]
Lee, Aaron Y. [5 ]
Lee, Cecilia S. [5 ]
Sen, H. Nida [1 ]
机构
[1] NEI, Bethesda, MD USA
[2] Cleveland Clin, Lerner Coll Med, Cleveland, OH USA
[3] Natl Lib Med, Bethesda, MD USA
[4] Cleveland Clin, Cole Eye Inst, Cleveland, OH USA
[5] Univ Washington, Seattle, WA USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2022年 / 11卷 / 07期
基金
美国国家卫生研究院;
关键词
fluorescein angiography; uveitis; machine learning; SEGMENTATION;
D O I
10.1167/tvst.11.7.19
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this paper was to develop a deep learning algorithm to detect retinal vascular leakage (leakage) in fluorescein angiography (FA) of patients with uveitis and use the trained algorithm to determine clinically notable leakage changes. Methods: An algorithm was trained and tested to detect leakage on a set of 200 FA images (61 patients) and evaluated on a separate 50-image test set (21 patients). The ground truthwas leakage segmentation by two clinicians. The Dice Similarity Coefficient (DSC) was used to measure concordance. Results: During training, the algorithm achieved a best average DSC of 0.572 (95% confidence interval [CI] = 0.548-0.596). The trained algorithm achieved a DSC of 0.563 (95% CI = 0.543-0.582) when tested on an additional set of 50 images. The trained algorithm was then used to detect leakage on pairs of FA images from longitudinal patient visits. Longitudinal leakage follow-up showed a >2.21% change in the visible retina area covered by leakage (as detected by the algorithm) had a sensitivity and specificity of 90% (area under the curve [AUC] = 0.95) of detecting a clinically notable change compared to the gold standard, an expert clinician's assessment. Conclusions: This deep learning algorithm showedmodest concordance in identifying vascular leakage compared to ground truth but was able to aid in identifying vascular FA leakage changes over time. Translational Relevance: This is a proof-of-concept study that vascular leakage can be detected in a more standardized way and that tools can be developed to help clinicians more objectively compare vascular leakage between FAs.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Automated Optic Nerve Head Detection in Fluorescein Angiography Fundus Images
    Tavakoli, M.
    Toosi, M. H. Bahreini
    Pourreza, R.
    Banaee, T.
    Pourreza, H. R.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3057 - 3060
  • [22] AUTOMATED DETECTION AND MEASUREMENTS OF FOVEAL AVASCULAR ZONE IN DIGITIZED FLUORESCEIN ANGIOGRAPHY
    MEUNIER, L
    MIMOUN, G
    BUNEL, P
    SOUBRANE, G
    GAUDAIRE, M
    COSCAS, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 941 - 941
  • [23] Quantifying Areas of Vascular Leakage in Sickle Cell Retinopathy Using Standard and Widefield Fluorescein Angiography
    Barbosa, Joshua
    Malbin, Brett
    Le, Kim
    Lin, Xihui
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2020, 51 (03): : 153 - 158
  • [24] Assessment of swept source optical coherence tomography angiography metrics in uveitis with vascular leakage on ultrawide field fluorescein angiography
    Shah, Ishan
    Sharma, Sumit
    Baynes, Kimberly
    Kaiser, Peter M.
    McDonald, Megan Ann
    Chen, Cindy
    Phuoc-Hanh Le
    Burton, Danielle X.
    Hamdan, Abel
    Srivastava, Sunil K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [25] An Unsupervised Adversarial Learning Approach to Fundus Fluorescein Angiography Image Synthesis for Leakage Detection
    Li, Wanyue
    He, Yi
    Wang, Jing
    Kong, Wen
    Chen, Yiwei
    Shi, GuoHua
    SIMULATION AND SYNTHESIS IN MEDICAL IMAGING, SASHIMI 2020, 2020, 12417 : 142 - 152
  • [26] Automated Quantitative Characterization of Retinal Vascular Features in Ultra-widefield Fluorescein Angiography
    Wang, Kevin
    Srivastava, Sunil K.
    Ehlers, Justis P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [27] OCT-angiography based artificial intelligence-inferred fluorescein angiography for leakage detection in retina [Invited]
    Murata, Toshinori
    Hirano, Takao
    Mizobe, Hideaki
    Toba, Shuhei
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (11) : 5851 - 5860
  • [28] Proof of Concept of Automated Collision Detection Technology in Rugby Sevens
    Clarke, Anthea C.
    Anson, Judith M.
    Pyne, David B.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (04) : 1116 - 1120
  • [29] Peripheral Retinal Vascular Leakage Demonstrated by Ultra-widefield Fluorescein Angiography in Preeclampsia with HELLP Syndrome
    Lin, Phoebe
    Hahn, Paul
    Fekrat, Sharon
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (08): : 1689 - 1690
  • [30] FLUORESCEIN ANGIOGRAPHY IN VASCULAR-LESIONS OF RETINA
    FRANCOIS, P
    CONSTAND.G
    TURUT, P
    DUFOUR, D
    LILLE MEDICAL, 1973, 18 (08): : 853 - 857