Pressure Control Design by Fieldbus System for the Pressure Gauge Calibration

被引:0
|
作者
Pornpatkul, Chatchaval [1 ]
Suksathid, Wipawan [2 ]
机构
[1] Pathumwan Inst Technol, Dept Instrumentat & Control Engn, Bangkok, Thailand
[2] Sipraya Polytech Coll, Dept Comp Technol, Bangkok, Thailand
来源
2013 13TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND SYSTEMS (ICCAS 2013) | 2013年
关键词
pressure control; fieldbus system; pressure gauge calibration;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presented the pressure control by Fieldbus system for the pressure gauge calibration. The data in control is standard communication. The programs for control system are classified into 2 parts, the one for controlling the external element and the other for creating the graphic display. The result of control can be monitor. The program for control can be create the function to computer and send the result to control external element. The program for creating graphic and monitor the result of control can be setting the method of monitoring and the result of control. We can be control the both of the programs for control the external element and the program for create graphic and monitor the result of the control system. Finally, the pressure gauge calibration using air pressure gauge as an intermediary is presented in this paper. The standard pressure gauge is calibrated in the working standard commonly used in the industry. The calibration method of DAkkS-DKD-R 6-1 standard guide line is deployed, where the error margin in measuring the pressure of the pressure gauge does not exceed the accuracy value to set by the factory manufacturers throughout the measurement range (+/- 0.5% of span). At least seven uncertainties are determined. It is found that the value of expanded uncertainty is significantly affected by some certain variables. The experimental result of the UUC studied in this paper show that the maximum error value of measurement is +0.008 kg/cm(2) at 2.0 kg/cm(2), which is in the range of accuracy value specified by the manufacturer (+/- 0.5% of span = +/- 0.02 kg/cm(2)). Moreover, when combining the maximum error value of the measurement obtained from the experiment with the expanded uncertainty (U-exp) = +/- 4.672 x 10(-3) kg/cm(2), it is also found that the result is still in the accuracy value specified by the manufacturer. Therefore, a calibration certificate of UUC can be issued for UUC utilization.
引用
收藏
页码:1565 / 1570
页数:6
相关论文
共 50 条
  • [21] DESIGN OF PRESSURE TRANSIENT CONTROL-SYSTEM
    DRIELS, M
    JOURNAL OF THE HYDRAULICS DIVISION-ASCE, 1975, 101 (NHY5): : 437 - 448
  • [22] PLOTS AND PRESSURE FOCUS ON FIELDBUS
    REEVE, A
    INTECH, 1993, 40 (07) : 21 - 23
  • [23] Design of an interferometric system for gauge block calibration
    Diz-Bugarin, Javier
    Dorrio, Benito V.
    Blanco, Jesus
    Miranda, Marta
    Outumuro, Ismael
    Luis Valencia, Jose
    OPTICAL ENGINEERING, 2013, 52 (04)
  • [24] The data acquisition and control system for the operation of ASDEX pressure gauge for the measurement of neutral pressure in ADITYA Tokamak
    Patel, Kiran
    Jadeja, K. A.
    Joshi, H. C.
    Ghosh, J.
    FUSION ENGINEERING AND DESIGN, 2019, 148
  • [25] Calibration of Manganin pressure gauge for diamond-anvil cells
    Chen, Jian
    Cheng, Hu
    Zhou, Xuefeng
    Yan, Xiaozhi
    Wang, Lingfei
    Zhao, Yusheng
    Wang, Shanmin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (03):
  • [26] Pressure calibration of diamond anvil Raman gauge to 310 GPa
    Akahama, Yuichi
    Kawamura, Haruki
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (04)
  • [27] Calibration of Differential Pressure Gauge for Ocean Bottom Seismology Study
    Wang, C. -C.
    Luo, X. -R.
    Chang, H. -C.
    Lin, C. -R.
    OCEANS 2017 - ABERDEEN, 2017,
  • [28] Pressure calibration of diamond anvil Raman gauge to 410 GPa
    Akahama, Yuichi
    Kawamura, Haruki
    INTERNATIONAL CONFERENCE ON HIGH PRESSURE SCIENCE AND TECHNOLOGY, JOINT AIRAPT-22 AND HPCJ-50, 2010, 215
  • [29] The Miniature Internal Electronic Pressure Gauge and Dynamic Calibration Method
    Zhang, Yu
    Zu, Jing
    Pei, Dongxing
    JOURNAL OF COMPUTERS, 2012, 7 (11) : 2750 - 2757
  • [30] Static Calibration System Design of Solid Pressure Sensor Based on LabVIEW
    Han, Ren
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 2079 - 2081