Fast-Spin-Echo Imaging of Inner Fields-of-View With 2D-Selective RF Excitations

被引:31
|
作者
Finsterbusch, Juergen [1 ,2 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Syst Neurosci, Hamburg, Germany
[2] Univ Med Ctr Hamburg Kiel Lubeck, Hamburg, Germany
关键词
fast-spin-echo imaging; FSE; inner field-of-view; 2DRF excitations; SAR; image blurring; PULSES; EPI; RESOLUTION; RARE;
D O I
10.1002/jmri.22196
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To demonstrate the feasibility of two-dimensional selective radio frequency (2DRF) excitations for fast-spin-echo imaging of inner fields-of-view (FOVs) in order to shorten acquisitions times, decrease RF energy deposition, and reduce image blurring. Materials and Methods: Fast-spin-echo images (in-plane resolution 1.0 x 1.0 mm(2) or 0.5 x 1.0 mm(2)) of inner FOVs (40 mm, 16 mm oversampling) were obtained in phantoms and healthy volunteers on a 3 T whole-body MR system using blipped-planar 2DRF excitations. Results: Positioning the unwanted side excitations in the blind spot between the image section and the slice stack to measure yields minimum 2DRF pulse durations (about 6 msec) that are compatible with typical echo spacings of fast-spin-echo acquisitions. For the inner FOVs, the number of echoes and refocusing RE pulses is considerably reduced which compared to a full FOV (182 mm) reduces the RE energy deposition by about a factor of three and shortens the acquisition time, e.g., from 39 seconds to 12 seconds for a turbo factor of 15 or from 900 msec to 280 msec for a single-shot acquisition. respectively. Furthermore, image blurring occurring for high turbo factors as in single-shot acquisitions is considerably reduced yielding effectively higher in-plane resolutions. Conclusion: Inner-FOV acquisitions using 2DRF excitations may help to shorten acquisitions times, ameliorate image blurring, and reduce specific absorption rate (SAP) limitations of fast-spin-echo (FSE) imaging, in particular at higher static magnetic fields.
引用
收藏
页码:1530 / 1537
页数:8
相关论文
共 44 条
  • [31] Volumetric measurement of human red nucleus with 3D fast spin echo T2-weighted sequence magnetic resonance imaging
    Rahimian, E.
    Tahsini, M.
    Vossough, A.
    Ohadi, B.
    JOURNAL OF NEUROLOGY, 2007, 254 : 107 - 107
  • [32] High-resolution T2-weighted MR imaging of the inner ear using a long echo-train-length 3D east spin-echo sequence
    Naganawa, S
    Yamakawa, K
    Fukatsu, H
    Ishigaki, T
    Nakashima, T
    Sugimoto, H
    Aoki, I
    Miyazaki, M
    Takai, H
    EUROPEAN RADIOLOGY, 1996, 6 (03) : 369 - 374
  • [33] Comparison of 3D-diffusion-prepared segmented steady-state free precession and 2D fast spin echo imaging of femoral artery atherosclerosis
    Katsumi Hayashi
    Venkatesh Mani
    Ajay Nemade
    Stephane Silvera
    Zahi A. Fayad
    The International Journal of Cardiovascular Imaging, 2010, 26 : 309 - 321
  • [34] Comparison of 3D vs. 2D fast spin echo imaging for evaluation of articular cartilage in the knee on a 3 T system scientific research
    Milewski, Matthew D.
    Smitaman, Edward
    Moukaddam, Hicham
    Katz, Lee D.
    Essig, David A.
    Medvecky, Michael J.
    Haims, Andrew H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1637 - 1643
  • [35] Comparison of 3D-diffusion-prepared segmented steady-state free precession and 2D fast spin echo imaging of femoral artery atherosclerosis
    Hayashi, Katsumi
    Mani, Venkatesh
    Nemade, Ajay
    Silvera, Stephane
    Fayad, Zahi A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (03): : 309 - 321
  • [36] Inner ear volume measurements using high resolution three-dimensional heavily T2-weighted fast spin-echo MR imaging: Initial experience
    Melhem, ER
    Shakir, H
    Bakthavachalam, S
    Macdonald, BC
    Caruthers, S
    Jara, H
    RADIOLOGY, 1998, 209P : 423 - 423
  • [37] Detection of focal hepatic lesions with MR imaging: Prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging
    Soyer, P
    deGivry, SC
    Gueye, C
    Lenormand, S
    Somveille, E
    Scherrer, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) : 1115 - 1121
  • [38] T2-weighted imaging of rectal cancer using a 3D fast spin echo sequence with and without deep learning reconstruction: A reader study
    Nguyen, Dan
    Palmquist, Sarah
    Hwang, Ken-Pin
    Ma, Jingfei
    Salem, Usama
    Sun, Jia
    Wang, Xinzeng
    Son, Jong Bum
    Ernst, Randy
    Wei, Peng
    Kaur, Harmeet
    Stanietzky, Nir
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
  • [39] MRCP: Does Parallel Imaging (ASSET) Improve Image Quality and Duct Visualization Using 2D Thick Slab Breath Hold Single-shot Fast Spin Echo (SSFSE) Imaging?
    Furlan, A.
    Almusa, O.
    Hosseinzadeh, K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [40] Directional Color Doppler Aids the 2D and 3D Prenatal Diagnosis of Cleft Lip and Palate With Antenatal Single-Shot Fast-Spin Echo Magnetic Resonance Imaging Confirmation
    Tonni, Gabriele
    Lituania, Mario
    JOURNAL OF DIAGNOSTIC MEDICAL SONOGRAPHY, 2012, 28 (04) : 187 - 189