A new method to test vertical ocular deviations using perilimbal light reflexes

被引:0
|
作者
Breyer, A [1 ]
Rütsche, A [1 ]
Gampe, E [1 ]
Mojon, DS [1 ]
机构
[1] Kantonsspital, Abt Strabol & Neuroophthalmol, CH-9007 St Gallen, Switzerland
关键词
diagnostic techniques; vertical ocular deviations; corneal light reflex;
D O I
10.1055/s-2003-38165
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: To develop a new diagnostic technique to determine vertical ocular deviations when the center of the pupil is covered by swollen eyelids in up- and downgaze. Patients and methods: In upgaze (downgaze) the reflex of a diagnostic lamp held at about 50 cm distance from the patient is observed on the lower (upper) limbus. In the case of an asymmetric reflex, prisms are used to obtain symmetrical reflexes. The amount of prisms indicates the size of the vertical misalignment. In five healthy volunteers, the angles of vertical changes of gaze position were plotted against the prism size needed to recenter the perilimbal reflex. Results: There was a linear correlation between the amount of upgaze changes in degrees and the strength of prisms used for compensation in degrees. This linear correlation was also found in downgaze. For both the correlation coefficient was r = 0.98 +/- 0.01. In upgaze the slope of the average regression line was 0.55 +/- 2.3degrees, in downgaze - 4.1 +/- 0.8degrees. A prism of +/- 1degrees corresponds in upgaze to a vertical deviation of about 1.3 +/- 0.14degrees, in downgaze to a deviation of about 1.1 +/- 0.07degrees. Conclusions: These results demonstrate that the perilimbal light reflex test is suitable for measuring simulated vertical ocular deviations. Therefore, the test may also be used in patients with vertical deviations who cannot be measured with classical methods. The method is more exact for measurements in upgaze.
引用
收藏
页码:86 / 88
页数:3
相关论文
共 50 条
  • [11] Myocardial Performance and Baroreceptor Reflexes in Preterm Neonates: An Echocardiographic Evaluation Using the Tilt Table Test Method
    P S Shekhawat
    C J Pelz
    P Sasidharan
    D A Lewis
    Pediatric Research, 1999, 45 : 30 - 30
  • [12] Myocardial performance and baroreceptor reflexes in preterm neonates: An echocardiographic evaluation using the tilt table test method
    Shekhawat, PS
    Pelz, CJ
    Sasidharan, P
    Lewis, DA
    PEDIATRIC RESEARCH, 1999, 45 (04) : 30A - 30A
  • [13] New Method of Vertical Alignment by using Nano-structure
    Kawamura, Tadashi
    Yamada, Yuichiro
    Okamoto, Kenji
    2009 SID INTERNATIONAL SYMPOSIUM DIGEST OF TECHNICAL PAPERS, VOL XL, BOOKS I - III, 2009, : 784 - 786
  • [14] HETEROCHROMATIC STRAY LIGHT IN UV ABSORPTION SPECTROMETRY - A NEW TEST METHOD
    MIELENZ, KD
    WEIDNER, VR
    BURKE, RW
    APPLIED OPTICS, 1982, 21 (18): : 3354 - 3356
  • [15] ESTIMATION OF LIGHT SCATTER IN OCULAR MEDIA USING PSYCHOPHYSICAL METHOD AND ITS RELATION TO LEGIBILITY
    Ayama, M.
    Murakami, R.
    Han, F.
    Tashiro, T.
    Ishikawa, T.
    Ohnuma, K.
    Shinoda, H.
    Araki, K.
    27TH SESSION OF THE CIE, VOL. 1, PTS 1 AND 2, 2011, : 589 - 592
  • [16] EVALUATE MATERIALS USING NEW NONDESTRUCTIVE TEST METHOD
    MCCANDLESS, JB
    IMGRAM, AG
    HYDROCARBON PROCESSING, 1976, 55 (10): : 159 - 161
  • [17] Analysis of the Oedometer Test Results Using a New Method
    Riad, Beshoy
    Zhang, Xiong
    MODELING, GEOMATERIALS, AND SITE CHARACTERIZATION (GEO-CONGRESS 2020), 2020, (317): : 321 - 331
  • [18] A new interpretation and quantitative method for diplopia test: 304 cases of ocular motor nerve palsy for clinical test and verify
    Ling-Yun Zhou
    Tie-Juan Liu
    Xue-Mei Li
    Chang Su
    Xiao-Jie Ji
    Ming Zhao
    International Journal of Ophthalmology, 2017, (11) : 1768 - 1770
  • [19] A new interpretation and quantitative method for diplopia test: 304 cases of ocular motor nerve palsy for clinical test and verify
    Zhou, Ling-Yun
    Liu, Tie-Juan
    Li, Xue-Mei
    Su, Chang
    Ji, Xiao-Jie
    Zhao, Ming
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (11) : 1768 - 1770
  • [20] Temperature test of photorefractive materials using light speed slowdown method
    Li Yanmin
    Li Mengchao
    Gang, Zheng
    Zhuang Songlin
    3RD INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, PARTS 1-3, 2007, 6723