Optimization of dual-band continuum light source for ultrahigh-resolution optical coherence tomography

被引:8
|
作者
Wang, Hui [1 ]
Rollins, Andrew M. [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
关键词
D O I
10.1364/AO.46.001787
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We demonstrate a dual-band continuum light source centered at 830 and 1300 nm. for optical coherence tomography (OCT) generated by pumping a photonic crystal fiber having two closely spaced zero-dispersion wavelengths with a femtosecond laser at 1059 nm. By use of polarization control, sidelobe suppression can be improved up to approximately 7.7 dB. By employing compression of the pump pulses, the generated spectrum is smooth and near-Gaussian, resulting in a point-spread function with negligible sidelobes. We demonstrate ultrahigh-resolution OCT imaging of biological tissue in vivo and in vitro using this light source and compare it with conventional-resolution OCT imaging at 1300 nm. (c) 2007 Optical Society of America.
引用
收藏
页码:1787 / 1794
页数:8
相关论文
共 50 条
  • [31] Simultaneous dual-band ultra-high resolution optical coherence tomography
    Spoeler, Felix
    Kray, Stefan
    Grychtol, Patrik
    Hermes, Barbara
    Bornemann, Joerg
    Foerst, Michael
    Kurz, Heinrich
    OPTICS EXPRESS, 2007, 15 (17) : 10832 - 10841
  • [32] Dual-band infrared optical coherence tomography using a single supercontinuum source
    Zorin, Ivan
    Gattinger, Paul
    Brandstetter, Markus
    Heise, Bettina
    OPTICS EXPRESS, 2020, 28 (06): : 7858 - 7874
  • [33] Dual-band optical coherence tomography using a single supercontinuum laser source
    Chen, Siyu
    Shu, Xiao
    Yi, Ji
    Fawzi, Amani
    Zhang, Hao F.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)
  • [34] Dual-band optical coherence tomography using a single supercontinuum laser source
    Chen, Siyu
    Shu, Xiao
    Yi, Ji
    Fawzi, Amani A.
    Zhang, Hao F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [35] The effect of water dispersion and absorption on axial resolution in ultrahigh-resolution optical coherence tomography
    Hillman, TR
    Sampson, DD
    OPTICS EXPRESS, 2005, 13 (06): : 1860 - 1874
  • [36] Adaptive optics using a liquid crystal spatial light modulator for ultrahigh-resolution optical coherence tomography
    Fernandez, Enrique J.
    Povazay, Boris
    Hermann, Boris
    Unterhuber, Angelika
    Sattmann, Harald
    Prieto, Pedro M.
    Leitgeb, Rainer
    Ahnelt, Peter
    Artal, Pablo
    Drexler, Wolfgang
    OPHTHALMIC TECHNOLOGIES XVI, 2006, 6138
  • [37] Optimization of compute unified device architecture for real-time ultrahigh-resolution optical coherence tomography
    Kim, Ji-hyun
    Aum, Jaehong
    Han, Jae-Ho
    Jeong, Jichai
    OPTICS COMMUNICATIONS, 2015, 334 : 308 - 313
  • [38] Volumetric Doppler angle correction for ultrahigh-resolution optical coherence Doppler tomography
    You, Jiang
    Li, Ang
    Du, Congwu
    Pan, Yingtian
    APPLIED PHYSICS LETTERS, 2017, 110 (01)
  • [39] Myocardial imaging using ultrahigh-resolution spectral domain optical coherence tomography
    Yao, Xinwen
    Gan, Yu
    Marboe, Charles C.
    Hendon, Christine P.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)
  • [40] Ultrahigh-resolution spectral domain optical coherence tomography imaging of the lamina cribrosa
    Kagemann, Larry
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Brennen, Peter M.
    Townsend, Kelly A.
    Gabriele, Michelle L.
    Schuman, Joel S.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (04) : S126 - S131